Skip to main content
Log in

Study on the Tautomer Interconversion of 3-Oxo Pentanoate During Gas Chromatography

  • Published:
Chromatographia Aims and scope Submit manuscript

Abstract

Enol and keto tautomers of methyl 3-oxo pentanoate could be separated on a HP-5 capillary column. The chromatographic peaks were identified by examining characteristic mass ions arose from the corresponding enol and keto molecular ions. The study showed that the area percentage of enol tautomer is a function of temperature of the column. Treating the column as a reactor, the energy of activation for the on-column tautomerization could be extracted (35.1 kJ mol−1) by monitoring the loss of the enol tautomer, because the reaction is found to obey pseudo first-order kinetics. The enthalpy and the entropy changes (ΔH = −3.98 kJ mol−1, ΔS = −7.89 J K−1mol−1) for the enol-to-keto reaction in the stationary phase were also obtained.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Giddings JC (1957) J Chem Phys 26:169–173

    Article  CAS  Google Scholar 

  • Thede R, Below E, Haberland D, Langer SH (1997) Chromatographia 45:149–154

    CAS  Google Scholar 

  • Thede R, Haberland D, Deng Z, Langer SH (1994) J Chromatogr A 683:279–291

    Article  CAS  Google Scholar 

  • Thede R, Below E, Haberland D, Fischer C, Below E, Langer SH (1998) J Liq Chrom & Rel Technol 21:208–102

    Google Scholar 

  • Burdett JL, Rogers MT (1964) J Am Chem Soc 86:2105–2109

    Article  CAS  Google Scholar 

  • Folkendt MM, Weiss-Lopez BE, Chauvel JP, Jr., True NS (1985) J Phys Chem 89:3347–3352

    Article  CAS  Google Scholar 

  • Belova NV, Oberhammer H, Girichev GV (2004) J. Phys. Chem A 108:3593–3597

    CAS  Google Scholar 

  • Schiavoni MM, Loreto HED, Hermann A, Mack HG, Ulic SE, Védova COD (2001) J Raman. Spectrosc. 32:319–329

    Google Scholar 

  • Terentev PB, Kalandarishvili AG (1996) Mass Spectrom. Rev. 15:339–363

    Google Scholar 

  • Masataka M, Atsushi K, Yohei H (1987) J Chromatogr 411:466–471

    Article  Google Scholar 

  • Masataka M, Atsushi K, Yohei H (1987) J Chromatogr 400:143–148

    Article  Google Scholar 

  • Skrdla PJ, Antoucci V, Lindemann C (2001) J Chromatogr Sci 39:431–440

    CAS  Google Scholar 

  • Jung M, Schurig V (1992) J Am Chem Soc 114:529–534

    Article  CAS  Google Scholar 

  • Schamp N, Vandewalle M (1966) J Bull Soc Chim Belg 759:539–550

    Google Scholar 

  • Bowie JH, Williams DH, Lowesson SO, Schroll G (1966) J Org Chem 31:1384–1390

    CAS  Google Scholar 

  • Masur M, Grützmacher HF, Münster H, Budzikiewicz H (1987) J Org Mass Spectrom. 22:493–500

    Google Scholar 

  • Krupcik J, Májeková M, Májek P, Hrouzek J, Benicka E, Onuska F, Sandra P, Zeeuw J (1995) Fresnius J Anal Chem 352:696–98

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jianyue Feng.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhao, Y., Feng, J., Chen, G. et al. Study on the Tautomer Interconversion of 3-Oxo Pentanoate During Gas Chromatography. Chroma 63, 161–166 (2006). https://doi.org/10.1365/s10337-005-0710-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1365/s10337-005-0710-9

Keywords

Navigation