Abstract

A newly modified extractor facilitated rapid extraction (10.0 mL, 1 h) of eleven phenols from XAD-4 resin for comparable recoveries to those with conventional Soxhlet extractor (80.0 mL, 3 h). Combined with analysis by gas chromatography and gas chromatography-mass spectrometry in selected ion monitoring mode as tert-butyldimethylsilyl derivatives, the overall method was linear (≥ 0.9991) with satisfactory precision (≤ 9.2% RSD), accuracy (≤ 7.7% RE), detection limit (≤ 0.02 μg L−1), and recovery rates (≥ 75.0%) in 0.05 to 1.0 μg L−1. Six phenolic pollutants were quantitatively screened along with bisphenol A (0.028 μg L−1) from river water.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

Download references

Acknowledgments.

This study was supported in part by the Ministry of Environment (Korea Environmental Research and development Fund, 1998) and in part by the Brain Korea 21 Project in 2003.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. R. Kim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Paik, M., Park, J., Koo, W. et al. Modification of Soxhlet Extractor for Rapid and Effective Recovery of Phenolic Pollutants Adsorbed on XAD-4 Resin. Chromatographia 60, 693–698 (2004). https://doi.org/10.1365/s10337-004-0444-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1365/s10337-004-0444-0

Keywords

Navigation