In this study, hydroxyapatite coatings were obtained with a vacuum plasma spray system at different power levels that were achieved by altering the plasma current and voltage. The effects of spray power level on coating characteristics were investigated. X-ray diffraction was used to identify the crystallinities of as-sprayed coatings, Electron Probe Microanalysis was employed to detect the surface chemical composition of as-sprayed coatings and Scanning Electron Microscopy revealed the microstructure. The results indicated that spray power greatly affected the crystallinity, chemical composition, and microstructure of as-sprayed hydroxyapatite coatings, which were linked to the melting state of hydroxyapatite powder.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. S. Ozawa and S. Kasugai, Evaluation of Implant Materials (Hydroxyapatite, Glass-ceramics, Titanium) in Rat Bone Marrow Stromal Cell Culture, Biomater., Vol 17, 1996, p 23–29

    Article  CAS  Google Scholar 

  2. V. Passi, V. Tarrible, W. Marin, A. Miotti, and A. Pareti, Hydroxyapatite in Oral Surgery: Clinical and Histological Results, Ceramics in Substitutive and Reconstructive Surgery, P. Vincenzini, Ed. Elsevier, 1991, p 467–476

  3. B.W. Schreurs, R. Huiskes, P. Buma, and T. J. H. Slooff, Biomedical and Histological Evaluation of a Hydroxyapatite-Coated Titanium Femoral Stem Fixed with an Intramedullary Morsellized Bone Grafting Technique: An Animal Experiment on Goat, Biomater., Vol 17, 1996, p 1177–1186

    Article  CAS  Google Scholar 

  4. J.A. Jansen, J.P.C.M. Van Der Waerden, and J.G.C. Wolke, A Histological Evaluation of the Effect of Hydroxyapatite Coating on Interfacial Response, J. Mater. Sci.: Mater. Med., Vol 4, 1993, p 466–470

    Article  CAS  Google Scholar 

  5. J. Li and L. Hermansoon, Mechanical Evaluation of Hot Isostatically Pressed Hydroxyapatite, Interceram, Vol 39 (No. 2), 1990, p 13–15

    CAS  Google Scholar 

  6. M. Akao, H. Aoki, and K. Kato, Mechanical Properties of Sintered Hydroxyapatite for Prosthetic Application, J. Mater. Sci., Vol. 16, 1981, p 809–812

    Article  CAS  Google Scholar 

  7. M. Jarcho, C.H. Bolen, M.B. Thomas, J. Bobick, J.F. Kay, and R.H. Doremus, Hydroxyapatite Synthesis and Characterization in Dense Polycrystalline Form, J. Mater. Sci., Vol 11, 1976, p 2027–2035

    Article  CAS  Google Scholar 

  8. K.A. Gross and C.C. Berndt, Thermal Spraying of Hydroxyapatite for Bioceramic Applications, Key Eng. Mater., Vol 53–55, 1991, p 124–129

    Article  Google Scholar 

  9. M. Schirkhanzadeh, Bioactive Calcium Phosphate Coatings Prepared by Electrodeposition, J. Mater. Sci. Lett., Vol 10, 1991, p 1415–1417

    Article  Google Scholar 

  10. M. Schirkhanzadeh, Electrochemical Fabrication of Bioactive Composite Coatings on Ti6A14V Surgical Alloy, Mater. Lett., Vol 14, 1992, p 27–30

    Article  Google Scholar 

  11. P. Li, K. de Groot, and T. Kokubo, Bioactive Ca10(PO4)6(OH)2-TiO2 Composite Coating Prepared by Sol-Gel Process, J. Sol-gel Sci. Technol., Vol 7, 1996, p 27–34

    Article  CAS  Google Scholar 

  12. H. Oguchi and G.W. Hastings, In Vivo Evaluation of Hydroxyapatite Sprayed by Different Coating Methods-One Year After Implantation, Bioceram., Vol 7, Ed., O.H. Andersson, 1994, p 215–221

    CAS  Google Scholar 

  13. K.A. Gross and C.C. Berndt, The Amorphous Phase in Plasma Sprayed Hydroxyapatite Coatings, Bioceram., Vol 8, J. Wilson, L.L. Hench, and D. Greenspan, Ed., Pergaman Press, 1995, p 361–368

    CAS  Google Scholar 

  14. T. Weidong, C. Jiyong, and Z. Xingdong, Amorphorization and Recrystallization During Plasma Spraying of Hydroxyapatite, Biomater., Vol 16, 1995, p 829–832

    Article  Google Scholar 

  15. E. L. Ellies, Crystallographic Changes in Calcium Phosphates during Plasma Spraying, Biomater., Vol 13 (No. 5), 1991, p 313–317

    Article  Google Scholar 

  16. K.A. Gross and C.C. Berndt, Optimization of Spraying Parameters for Hydroxyapatite, 2nd Plasma Technik Symposium, Vol 3, S. Bum, Sondmeier, H. Eschnduer, P. Huber, and A.R. Nicoll, Ed., Plasma Technik AG, Lucerne, Switzerland, 1991, p 159–170

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chang, C., Shi, J., Huang, J. et al. Effects of power level on characteristics of vacuum plasma sprayed hydroxyapatite coating. J Therm Spray Tech 7, 484–488 (1998). https://doi.org/10.1361/105996398770350693

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1361/105996398770350693

Keywords

Navigation