13 K thermally coupled two-stage Stirling-type pulse tube refrigerator

  • Brief Communications
  • Published:
Chinese Science Bulletin

Abstract

Stirling-type pulse tube refrigerators have attracted academic and commercial interest in recent years due to their more compact configuration and higher efficiency than those of G-M type pulse tube refrigerators. In order to achieve a no-load cooling temperature below 20 K, a thermally coupled two-stage Stirling-type pulse tube refrigerator has been built. The thermally coupled arrangement was expected to minimize the interference between the two stages and to simplify the adjustment and optimization of the phase shifters. A no-load cooling temperature of 14.97 K has been realized with the two-stage cooler driven by one linear compressor of 200 W electric input. When the two stages are driven by two compressors respectively, with total electric input of 400 W, the prototype has attained a no-load cooling temperature of 12.96 K, which is the lowest temperature ever reported with two-stage Stirling-type pulse tube refrigerators.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Matsubara, Y., Gao, J. L., Novel configuration of three-stage pulse tube refrigerator for temperatures below 4 K, Cryogenics, 1994, 34(4): 259–262.

    Article  Google Scholar 

  2. Wang, C., Thummes, G., Heiden, C., Atwo-stage pulse tube cooler operating below 4K, Cryogenics, 1997, 37(3): 159–164.

    Article  Google Scholar 

  3. Chen, G. B., Qiu, L. M., Zheng, J. Y. et al., Experimental study on a double-orifice two-stage pulse tube refrigerator, Cryogenics, 1997, 37(5): 271–273.

    Article  Google Scholar 

  4. Wang, C., Gifford, P. E., Two-stage pulse tube cryocoolers for 4 K and 10 K operation, Cryocoolers 12, New York: Kluwer Academic/Plenum Publishers, 2003, 293–300.

    Google Scholar 

  5. Nast, T. C., Olson, J., Evtimov, B. et al., Development of a two-stage pulse tube cryocooler for 35 K cooling, Cryocoolers 12, New York: Kluwer Academic/Plenum Publishers, 2003: 213–218.

    Google Scholar 

  6. Olson, J., Nast, T. C., Evtimov, B. et al., Development of a 10 K pulse tube cryocooler for space applications, Cryocoolers 12, New York: Kluwer Academic/Plenum Publishers, 2003, 241–246.

    Google Scholar 

  7. Nguyen, C., Yeckley, A., Culler, A. et al., Hydrogen/oxygen propellant densifier using a two-stage pulse tube cryocooler, Adv. Cryo. Eng., New York: Plenum Press, 2004, 49(B): 1703–1709.

    Google Scholar 

  8. Yang, L. W., Thummes, G., High frequency two-stage pulse tube cryocooler with base temperature below 20 K, Cryogenics, 2005, 45(2): 155–159.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ke Tang.

About this article

Cite this article

Tang, K., Chen, G. & Thummes, G. 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator. Chin.Sci.Bull. 50, 1814–1816 (2005). https://doi.org/10.1360/982005-750

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1360/982005-750

Keywords

Navigation