Skip to main content
Log in

A separate two-stage pulse tube cooler working at liquid helium temperature

  • Articles
  • Published:
Chinese Science Bulletin

Abstract

A novel 4 K separate two-stage pulse tube cooler (PTC) was designed and tested. The cooler consists of two separate pulse tube coolers, in which the cold end of the first stage regenerator is thermally connected with the middle part of the second regenerator. Compared to the traditional coupled multi-stage pulse tube cooler, the mutual interference between stages can be significantly eliminated. The lowest refrigeration temperature obtained at the first stage pulse tube was 13.8 K. This is a new record for single stage PTC. With two compressors and two rotary valves driving mode, the separate two-stage PTC obtained a refrigeration temperature of 2.5 K at the second stage. Cooling capacities of 508 mW at 4.2 K and 15 W at 37.5 K were achieved simultaneously. A one-compressor and one-rotary valve driving mode has been proposed to further simplify the structure of separate type PTC.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Gao, J. L., Matsubara, Y., Experimental study of 4 K pulse tube refrigerator, Cryogenics, 1994, 34(1): 25–30.

    Article  CAS  Google Scholar 

  2. Wang, C., Thummes, G., Heiden, C., A two-stage pulse tube cooler operating below 4 K, Cryogenics, 1997, 37(3): 159–164.

    Article  CAS  Google Scholar 

  3. Chen, G. B., Qiu, L. M., Zhen, J. Y. et al., Experimental study on a double-orifice two-stage pulse tube refrigerator, Cryogenics, 1997, 37(5): 271–273.

    Article  CAS  Google Scholar 

  4. Qiu, L. M., Thummes, G., Valve timing effect on the cooling performance of a 4 K pulse tube cooler, Cryogenics, 2002, 42(5): 327–333.

    Article  CAS  Google Scholar 

  5. Qiu, L. M., Numazawa, T., Thummes, G., Performance improvement of a pulse tube cooler below 4 K by use of GdAlO3 regenerator material, Cryogenics, 2001, 41(9): 693–696.

    Article  CAS  Google Scholar 

  6. Wang, C., Thummes, G., Heiden, C., Effects of DC gas flow on performance of two-stage 4 K pulse tube coolers, Cryogenics, 1998, 38(6): 689–695.

    Article  CAS  Google Scholar 

  7. Jiang, N., Lindemann, U., Giebeler, F. et al., A 3He pulse tube cooler operating down to 1.3 K, Cryogenics, 2004, 44(11): 809–816.

    Article  CAS  Google Scholar 

  8. Zhu, S. W., Nogawa, M., Katsuragawa, S. et al., Performance of a 4 K pulse tube refrigerator and its improvement, Cryocooler vol.12, New York: Plenum Press, 2003, 309–315.

    Google Scholar 

  9. Chen, G. B., Jiang, Y. L., Gan, Z. H., A novel pulse tube cooler with double-orifice and double-inlet, Chinese patent, No. 02 1 12249.2, 2004-07-21.

  10. Qiu, L. M., Jiang, N., Giebeler, F. et al., A pulse tube cooler capable of 1W at 4.2 K, Cryogenics and Refrigeration-Proceedings of ICCR’2003 (eds. Chen, G. B., Hebral, B., Chen, G. M.), Beijing: International Academic Publishers, 2003, 113–116.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Qiu Limin.

About this article

Cite this article

Limin, Q., Yonglin, H., Zhihua, G. et al. A separate two-stage pulse tube cooler working at liquid helium temperature. Chin.Sci.Bull. 50, 1030–1033 (2005). https://doi.org/10.1360/982005-187

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1360/982005-187