Abstract
The purpose of this work was to study the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to determine product dry-layer resistance to vapor flow. Product temperature and dry-layer resistance were obtained using MTM software installed on a laboratory freeze-dryer. The MTM resistance values were compared with the resistance values obtained using the “vial method.” The product dry-layer resistances obtained by MTM, assuming fixed temperature difference (ΔT; 2°C), were lower than the actual values, especially when the product temperatures and sublimation rates were low, but with ΔT determined from the pressure rise data, more accurate results were obtained. MTM resistance values were generally lower than the values obtained with the vial method, particularly whenever freeze-drying was conducted under conditions that produced large variations in product temperature (ie, low shelf temperature, low chamber pressure, and without thermal shields). In an experiment designed to magnify temperature heterogeneity, MTM resistance values were much lower than the simple average of the product resistances. However, in experiments where product temperatures were homogenous, good agreement between MTM and “vial-method” resistances was obtained. The reason for the low MTM resistance problem is the fast vapor pressure rise from a few “warm” edge vials or vials with low resistance. With proper use of thermal shields, and the evaluation of ΔT from the data, MTM resistance data are accurate. Thus, the MTM method for determining dry-layer resistance is a useful tool for freeze-drying process analytical technology.
Similar content being viewed by others
References
Pikal MJ. Lyophilization. In: Dekker M, ed. Encylopedia of Pharmaceutical Technology. 2001: 1299–1326.
Carpenter JF, Pikal MJ, Chang BS, Randolph TW. Rational design of stable lyophilized protein formulations: some practical advice. Pharm Res. 1997;14:969–975.
Tang X, Pikal MJ. Design of freeze-drying processes for pharmaceuticals: practical advice. Pharm Res. 2004;21:191–200.
Milton N, Pikal MJ, Roy ML, Nal SL. Evaluation of manometric temperature measurement as a method of monitoring product temperature during lyophilization. PDA J Pharm Sci Technol 1997;51:7–16.
Overcashier DE, Patapoff TW, Hsu CC. Lyophilization of protein formulations in vials: investigation of the relationship between resistance to vapor flow during primary drying and small-scale product collapse. J Pharm Sci. 1999;88:688–695.
Pikal MJ, Shah S, Senior D, Lang JE. Physical chemistry of freeze-drying: measurement of sublimation rates for frozen aqueous solutions by a microbalance technique. J. Pharm Sci 1983;72:635–650.
Searles JA, Carpenter JF, Randolph TW. Annealing to optimize the primary drying rate, reduce freezing-induced drying rate heterogeneity, and determine Tg' in pharmaceutical lyophilization. J Pharm Sci. 2001;90:872–887.
Lu X, Pikal MJ. Freeze-drying of mannitol-trehalose-sodium chloride-based formulations: the impact of annealing on dry-layer resistance to mass transfer and cake structure. Pharm Dev Technol. 2004;9:85–95.
Pikal MJ, Roy ML, Shah S. Mass and heat transfer in vial freeze-drying of pharmaceuticals: role of the vial. J Pharm Sci. 1984;73:1224–1237.
Pikal MJ. Use of laboratory data in freeze drying process design: heat and mass transfer coefficients and the computer simulation of freeze drying. J Parenter Sci Technol. 1985;39:115–139.
Tang XC, Nail SL, Pikal MJ. Mass Transfer in Freeze Drying: Measurement of Dry-layer Resistance by a Non-Steady State Method (the MTM Procedure). Paper presented at: AAPS Annual Meeting: November 14–18; New Orleans, LA. 1999.
Jancso G, Pupezin J, Van Hook WA. The vapor pressure of ice between 0.01 and −100C. J Phys Chem. 1970;74:2984–2989.
Chang L, Tang X, Pikal MJ, Milton N, Thomas L. The Origin of Multiple Glass Transitions in Frozen Aqueous Solutions. Proceeding NATAS Annual Conference Thermal Analysis and Applications. Bowling Green, NY, NATAS. 1999:624–628.
Shamblin SL, Tang X, Chang L, Hancock BC, Pikal MJ. Characterization of the time scales of molecular motion in pharmaceutically important glasses. J Phys Chem B 1999;103:4113–4121.
Tang X, Nail SL, Pikal MJ. Evaluation of manometric temperature measurement (MTM) in freeze drying. Part I: product temperature measurement [serial online]. AAPS PharmSciTech. 2006;7:E14.
Nail SL. The effect of chamber pressure on heat transfer in the freeze drying of parenteral solutions. J Parenter Drug Assoc. 1980;34:358–368.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published: December 1, 2006
Rights and permissions
About this article
Cite this article
Tang, X.C., Nail, S.L. & Pikal, M.J. Evaluation of manometric temperature measurement, a process analytical technology tool for freeze-drying: Part II measurement of dry-layer resistance. AAPS PharmSciTech 7, 93 (2006). https://doi.org/10.1208/pt070493
Received:
Accepted:
Published:
DOI: https://doi.org/10.1208/pt070493