Abstract
Recently, flexible sensors with high sensitivity have been applied in wearable sports sensing field. Here, we reported a flexible and sensitive capacitive pressure sensor based on nylon textile and polyvinylidene fluoride (PVDF) dielectric film. From the experimental results, the sensor has an extremely high sensitivity of 33.5 kPa−1, a low detection limit of 0.84 Pa, a quick response time of 27 ms. Moreover, the pressure sensor shows excellent reliability under over 100,000 working cycles. With their superior overall performance, capacitive sensors have effectively proved their enormous potential for basketball motion monitoring. This research will promote the development of wearable sports sensors.
Similar content being viewed by others
Introduction
With the rising need for fast-growing artificial intelligence and the Internet of Things (IoT), flexible pressure sensors, one of the critical sensing components, hold promise in medical diagnostics, medical monitoring, and wearable electronics for humans [1, 2]. It is worth noting that wearable sports training equipment based on flexible pressure sensors has received widespread attention [3]. Flexible pressure sensors generally convert applied force to a recognized electrical signal or other responsive output signal to discriminate between external stimuli [4, 5]. The flexible pressure sensor can sense various posture information of human motion [6]. Sensitivity, response time, the limit of detection (LOD), and operational stability are often used to assess the performance of pressure sensors [6,7,8,9].
Also, piezoresistive sensors, capacitive sensors, piezoelectric sensors, and triboelectric sensors are the four main types of sensors based on their detecting methods [10,11,12]. Flexible capacitive pressure sensors (FCPSs) have been extensively investigated because of its high sensitivity, short response time, and minimal hysteresis [13, 14]. The FCPS device may be embedded in a variety of uneven surfaces, including touchscreens, flexible displays, and even human skin [15]. The FCPS devices are made of two parallel flexible conductive planes (upper and lower electrodes) separated by a dielectric layer such as polyvinylidene fluoride (PVDF) or methacrylate [16,17,18]. To increase the sensitivity of FCPS, different delicate structures such as wavy, columnar, pyramidal, and micro-convex are employed as electrodes or dielectric layers [19]. For instance, Park’s group employed a porous Ecoflex dielectric layer to create a sensor with a sensitivity of 0.6 kPa−1 [20]. The Guo’s group achieved the sensor’s high sensitivity of 1.54 kPa−1 by employing microstructured rose petals and leaves as the sensor’s dielectric layer [20]. Besides, nylon mesh is a low-cost dielectric layer that may be used to increase application sensitivity (0.33 kPa−1, two-step replication of lotus leaves on PMDS surface as the electrode, and 0.815 kPa−1 sensitivity of polystyrene microsphere as a dielectric layer) [21]. However, the sensitivity of these sensors still cannot meet the needs. Therefore, the development of FCPS with high sensitivity and excellent working stability still has a long way to go [22, 23].
In this work, we reported a flexible and sensitive capacitive pressure sensor based on nylon textile and polyvinylidene fluoride (PVDF) dielectric film. As we all known, the PVDF film is a high dielectric material with good flexibility and biocompatibility; therefore, it is widely used in the field of human motion sensing. And the PVDF layer was manufactured using a simple spin-coating procedure. From the experimental results, the sensor has an extremely high sensitivity of 33.5 kPa−1, a low detection limit of 0.84 Pa, a quick response time of 27 ms. The sensor still maintains good stability after 100,000 cycles of continuous operation. According to results, the NSR of pressure sensor can reach 3 dB. Besides, the pressure sensor can monitor the breath, pulse, and elbow movement posture in basketball. Furthermore, the pressure sensor can also be used as a touch sensor to judge the hardness of the object, which promote its application in IoT sensor nodes.
Experimental
Materials
The nylon textile and conductive copper foil were purchased from the mall. Sinopharm Chemical Reagent Co., Ltd., sells sulfuric acid (H2SO4, 98%), N-methyl pyrrolidone (NMP, AR), hydrogen peroxide (H2O2, 30%), and ethanol (C2H5OH, 98%). All investigations were conducted using ultrapure water (> 18 MΩ·cm−1).
Preparation of dielectric film
A PVDF/NMP solution (PVDF: NMP = 1:10, w/w) is made by dissolving the desired quantity of PVDF powder in the NMP solvent and then spinning evenly at 600 rpm for 10 s on a clean glass substrate coated with spin. The PVDF film (40 µm) was carefully pulled away from the glass after 30 min of drying at 80 °C. Dielectric layers with different thickness were created by spinning at 400 rpm for 10 s, respectively.
Fabrication of the FCPS
FCPS was manufactured by cutting a piece of nylon textile into 1 cm × 1 cm, connecting wireway leads to a piece of external test equipment, and surface sticking one end of the cut electrode with a commercially available copper foil. Then, using the PVDF film as an intermediary layer. Then, the dielectric film is clamped in the middle with two layers of nylon film with conductive copper electrode to form the flexible pressure sensors.
Results and discussion
As shown in Fig. 1a-c, a piece of PVDF film was fabricated by spin coating. Then, the PVDF film was cut into 1 cm × 1 cm, as illustrated in Fig. 1d. Two pieces of nylon textile (thickness: 80 μm) wrap PVDF film in the middle, as shown in Fig. 1e. Next, a layer of copper foil (thickness: 50 μm) is pasted on the surface of nylon textile as conductive electrode, as presented in Fig. 1f. Figure 1g illustrates the picture of FCPS device. And the inset in Fig. 1g presents the flexibility of FCPS device. Figure 1h shows the SEM image of the nylon textile surface. Because nylon fiber has surface texture structure, this texture structure will deform when contacting with PVDF, resulting in the change of capacitance of the device, so as to achieve the effect of pressure sensing.
To evaluate the effect of dielectric layer thickness on sensing performance, the thickness of PVDF film varies from 40 to 70 µm. According to the results shown in Fig. 2a, when the thickness of PVDF film is 40 µm, FCPS has the best sensing performance. Furthermore, in the low pressure rang (0–200 Pa), the sensitivity of pressure sensor was up to 33.5 kPa−1, which is higher than previous work [22,23,24,25]. The synergistic impact of the altered contact area and face-to-face separation results in an exponential rise in capacitance, boosting the sensor’s sensitivity. The schematic diagram in Fig. 2b depicts the rate of change in capacitance in response to external pressure. Here, “d” and “A” denote parallel plates’ height and contact area changes, respectively. A is almost constant with regard to the pressure load applied by FCPS. The influence on capacitance changes is minimal. The d induced by the elastic dielectric layer deformation contributes to the different capacitances. In addition, we also develop the influence of the area (A) of the pressure sensor. In detail, the quantitative relationship between A/d and applied pressure is shown in Fig. 2c. In the FCPS pressure load instance, d and A both contribute to the capacitance shift, as shown in Fig. 2c, d. Thus, when pressure is applied to the FCPS, the distance between the two electrodes and the contact area changes dramatically, improving sensitivity significantly. The working mechanism of pressure sensor is shown in Fig. 2h. Due to the extremely fine texture on the surface of nylon fiber, when the pressure sensor is not under pressure, the nylon fiber layer will remain loose, which leads to the small capacitance of the pressure sensor. At the same time, when the pressure sensor is not under pressure, the PVDF film is in the maximum thickness state, which will also reduce the capacitance of the sensor. When the pressure sensor is subjected to external pressure, the loose nylon fiber will be compressed, resulting in an increase in the capacitance of the device. Furthermore, the PVDF film will also become thinner under pressure, thus increasing the capacitance of the sensor. As the capacitance of the pressure sensor changes greatly before and after being subjected to pressure, it also leads to the high sensitivity and testing range of the pressure sensor. The relevant discussion information has been added to the manuscript.
Other critical factors determined using lightweight items as external pressure are FCPS response time and detection limit. To generate a steady capacitive response signal throughout the load and unload cycles, a mica layer was put on the sensor to cover the surface. The size of the mica layer is about 1.2 cm × 1.2 cm, and the weight of the mica layer is about 95 mg. The pressure load and unload time response curves for FCPS are shown in Fig. 3a. During load and unload cycles, the harvested capacitive signals demonstrated the response time and relaxation time of 27 ms and 52 ms, respectively. As shown in Fig. 3b, a coin was put at a static pressure of 0.84 Pa on the surface of FCPS. The formula for calculating static pressure is P = mg/S. Here, m represents the mass of 32 mg of the coin, g represents the gravitational acceleration of 9.8 N/kg, and S represents the sensor’s effective area of π × 1.2 cm × 1.2 cm. The capacitance signal curve repeatedly varies when the coin is loaded and unloaded. This demonstrates that the sensor can detect and convert tiny inputs into a discernible response signal, and this sensor is better than previous work [26, 27]. Moreover, according to the characteristics of the test signal in Fig. 3a, it can be estimated that the SNR of the sensor is about 3 dB. As shown in Fig. 3c, even after 100,000 load/unload cycles, full performance is maintained, confirming FCPS repeatability and stability. The preceding findings demonstrate that the sensor as designed has considerable promise for detecting small pressures in real-world applications with high accuracy and outstanding long-term stability.
Physiological signals and bodily motions are critical for health monitoring. As shown in Fig. 4a, FCPS is utilized to detect numerous motions, such as elbow flexion in basketball motion. Specifically, the FCPS sensor is linked to several points on the human body, including the neck, wrists, arms, and legs. The measurement of respiratory rate has significant consequences for basketball motion. The respiratory signal received from the sensor to detect pressure changes caused by breath fluctuation before and after basketball sports is shown in Fig. 4b. When subjects were calm, they breathed at an average rate of 18 breaths per minute, indicating the possible use of pressure sensors in basketball motion monitoring of aberrant breathing rates. The FCPS is linked to a volunteer’s wrist to illustrate the application in pulse detection, and the findings are given in Fig. 4c. The curve graphically depicts the change in capacitance generated by the pulse and the form of a stable and repeatable pulse. Additionally, a sensor that detects the arm’s bending is linked to the joint. As shown in Fig. 4d, bending the arm about 30 and 60 degrees raises the capacitance of the sensor from 385 to 440 pF and 465 pF, respectively, and the sensor maintains a continuous bending relaxation cycle. The leg flexion signal is shown in Fig. 4e when the transducer is linked to the thigh muscle. Due to the sensor’s excellent sensitivity and stability, you may notice a consistent capacitance curve throughout the operation. These findings demonstrate the enormous potential of flexible capacitive pressure sensors as running motion monitoring devices for monitoring human basketball motion in real time.
The combination of artificial intelligence and sensors determines the user’s intention in real time by tracking contextual information, such as the user’s profile, environmental conditions, and sight tracker. The combination of artificial intelligence and sensor technology is a development direction of intelligent sensor, because it improves the intelligence of sensor. To examine the FCPS-practical detecting capacity as a tactile sensor, a capacitance sensor was mounted to the surface of glove surface, as shown in Fig. 5a. An LCR tester records the capacitance signal from the sensor in real time, and LabVIEW graphically shows it on the computer screen. The electrical signal curves obtained by gripping a sponge (a soft object), a tangerine (a medium-hard item), and a can (a hard object) are shown in Fig. 5b-d. Release the grasping action for about 0.5 s, and then, reintroduce it for approximately 1 s. Repeat the above actions three times. For instance, since the sponge is light and readily distorted, the force applied to the sponge progressively rises during the grasping process. Not only is the tangerine heavy, but its surface is resistant to deformation, ensuring that the sensor signal remains constant during the gripping process. In conclusion, positive experimental findings demonstrate that capacitive sensors have great sensitivity, rapid reaction time, and excellent cycle stability, making them ideal for medical diagnostics and human–computer interaction.
Conclusion
In summary, a low-cost and straightforward capacitive pressure sensor based on nylon textile and PVDF dielectric layer was proposed. The sensor has an extremely high sensitivity of 33.5 kPa−1, a low detection limit of 0.84 Pa, a quick response time of 27 ms. The sensor still maintains good stability after 100,000 cycles of continuous operation. According to results, the NSR of pressure sensor can reach 3 dB. Besides, the pressure sensor can monitor the breath, pulse, and elbow movement posture in basketball. Furthermore, the pressure sensor can also be used as a touch sensor to judge the hardness of the object, which promote its application in IoT sensor nodes.
Availability of data and materials
All data and materials are available without restrictions.
References
Lee S, Shi Q, Lee C. From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks. APL Mater. 2019;7(3): 031302.
Park JH, Lee HE, Jeong CK, et al. Self-powered flexible electronics beyond thermal limits. Nano Energy. 2019;56:531–46.
Luo Y, Wang M, Wan C, et al. Devising materials manufacturing toward lab-to-fab translation of flexible electronics. Adv Mater. 2020;32(37):2001903.
Zhang Z, He T, Zhu M, et al. Deep learning-enabled triboelectric smart socks for IoT-based gait analysis and VR applications. NPJ Flexible Electron. 2020;4(1):1–12.
Shao L, Lei T, Huang TC, et al. Compact modeling of thin-film transistors for flexible hybrid IoT design. IEEE Des Test. 2019;36(4):6–14.
Bhattacharjee M, Nikbakhtnasrabadi F, Dahiya R. Printed chipless antenna as flexible temperature sensor. IEEE Internet Things J. 2021;8(6):5101–10.
Ramalho JFCB, Correia SFH, Fu L, et al. Super modules-based active QR codes for smart trackability and IoT: a responsive-banknotes case study. NPJ Flexible Electron. 2020;4(1):1–9.
Cardenas JA, Andrews JB, Noyce SG, et al. Carbon nanotube electronics for IoT sensors. Nano Futures. 2020;4(1): 012001.
Saha T K, Knaus T N, Khosla A, et al. A CPW-fed flexible UWB antenna for IoT applications. Microsyst Technol 2018: 1-7.
Aliqué M, Simão CD, Murillo G, et al. Fully-printed piezoelectric devices for flexible electronics applications. Adv Mater Technol. 2021;6(3):2001020.
Cetin MS, Toprakci HAK. Flexible electronics from hybrid nanocomposites and their application as piezoresistive strain sensors. Compos B Eng. 2021;224: 109199.
Yang Y, Yang Y, Cao Y, et al. Anti-freezing, resilient and tough hydrogels for sensitive and large-range strain and pressure sensors. Chem Eng J. 2021;403: 126431.
Shi Q, He T, Lee C. More than energy harvesting–Combining triboelectric nanogenerator and flexible electronics technology for enabling novel micro-/nano-systems. Nano Energy. 2019;57:851–71.
Wang Y, Zhang L, Lu A. Highly stretchable, transparent cellulose/PVA composite hydrogel for multiple sensing and triboelectric nanogenerators. J Mater Chem A. 2020;8(28):13935–41.
Shi Q, Zhang Z, Chen T, et al. Minimalist and multi-functional human machine interface (HMI) using a flexible wearable triboelectric patch. Nano Energy. 2019;62:355–66.
Deng J, Kuang X, Liu R, et al. Vitrimer elastomer-based jigsaw puzzle-like healable triboelectric nanogenerator for self-powered wearable electronics. Adv Mater. 2018;30(14):1705918.
Zhou K, Zhao Y, Sun X, et al. Ultra-stretchable triboelectric nanogenerator as high-sensitive and self-powered electronic skins for energy harvesting and tactile sensing. Nano Energy. 2020;70: 104546.
Tao K, Yi H, Yang Y, et al. Miura-origami-inspired electret/triboelectric power generator for wearable energy harvesting with water-proof capability. Microsyst Nanoeng. 2020;6(1):1–11.
Wu Y, Qu J, Daoud WA, et al. Flexible composite-nanofiber based piezo-triboelectric nanogenerators for wearable electronics. J Mater Chem A. 2019;7(21):13347–55.
Wan Y, Qiu Z, Huang J, et al. Natural plant materials as dielectric layer for highly sensitive flexible electronic skin. Small. 2018;14(35):1801657.
He Z, Chen W, Liang B, et al. Capacitive pressure sensor with high sensitivity and fast response to dynamic interaction based on graphene and porous nylon networks. ACS Appl Mater Interfaces. 2018;10(15):12816–23.
Fu M, Zhang J, Jin Y, et al. A highly sensitive, reliable, and high-temperature-resistant flexible pressure sensor based on ceramic nanofibers. Adv Sci. 2020;7:2000258.
Bai N, Wang L, Wang Q, et al. Graded intrafillable architecture-based iontronic pressure sensor with ultra-broad-range high sensitivity. Nat Commun. 2020;11:1–9.
Xu H, Gao L, Zhao H, et al. Stretchable and anti-impact iontronic pressure sensor with an ultrabroad linear range for biophysical monitoring and deep learning-aided knee rehabilitation. Microsyst Nanoeng. 2021;7:1–11.
Xu H, Gao L, Wang Y, et al. Flexible waterproof piezoresistive pressure sensors with wide linear working range based on conductive fabrics. Nano-micro Lett. 2020;12:1–13.
Shuai X, Zhu P, Zeng W, et al. Highly sensitive flexible pressure sensor based on silver nanowires-embedded polydimethylsiloxane electrode with microarray structure. ACS Appl Mater Interfaces. 2017;9(31):26314–24.
Li T, Luo H, Qin L, et al. Flexible capacitive tactile sensor based on micropatterned dielectric layer. Small. 2016;12(36):5042–8.
Acknowledgements
Not applicable.
Funding
Not applicable.
Author information
Authors and Affiliations
Contributions
Huijie Gao contributed to conceptualization, formal analysis, and writing—original draft preparation; Tiangeng Chen was involved in writing—review and editing, visualization, and supervision. All authors have read and agreed to the published version of the manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Gao, H., Chen, T. A flexible ultra-highly sensitive capacitive pressure sensor for basketball motion monitoring. Discover Nano 18, 17 (2023). https://doi.org/10.1186/s11671-023-03783-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s11671-023-03783-y