Background
Novel motion-corrected single-shot phase sensitive inversion recovery (PSIR) late gadolinium enhancement (moco-LGE) cardiovascular MR in 3.0T system may have advantages over conventional segmented breath-held LGE (bh-LGE), especially for vulnerable patients with arrhythmia or respiratory motions.
Methods
In a consecutive cohort of 58 patients referred for clinical enhanced cardiac MR, bh-LGE and moco-LGE were collected contemporarily with identical image parameters using a 3.0T scanner. The moco-LGE was acquired just after the bh-LGE while the patients were asked to breathe freely. Images were randomized and scored for image quality (1-very poor and not analyzable, 2-poor, 3-acceptable, 4-good, 5-very good) and diagnostic confidence for myocardial LGE (1-low confidence, 2-some confidence, 3-high confidence) separately base on the American Heart Association 17-segmented model. In patients with diagnostic image quality and definite LGE with identifiable margin, the myocardial LGE mass was quantified. Paired t test was used to compare the image quality, diagnostic confidence. Linear regression and correlation plots were used to compare LGE mass.
Results
55 patients had regular heart rate (HR), the mean HR was 78±14 beats per minute (bpm). The other 3 patient had irregular HR including atrial fibrillation and atrial flutter. In all the patients, the moco-LGE with free-breathing had similarly high image quality (3.9±0.9 vs 3.7±0.9, P=0.410), and diagnostic confidence (2.8±0.3 vs 2.7±0.4, P=0.743) compared with bh-LGE. A total of 16 patients with marked image artifacts in bh-LGE for arrhythmia or respiratory motion, moco-LGE had significantly higher image quality (3.8±0.8 vs 3.0±0.9, P=0.000) and confidence(2.8±0.2 vs 2.4±0.4, P=0.000). The myocardial LGE mass was quantified and compared in 22 patients, the results correlated highly (R2=0.95, P=0.000) without bias.
Conclusions
In general, moco-LGE and bh-LGE have similar image quality and myocardial LGE quantification. In vulnerable patients with marked artifacts of bh-LGE, moco-LGE probably has higher image quality and diagnostic confidence.
Funding
N/A.
Author information
Authors and Affiliations
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Lin, L., Wang, Y., Cao, J. et al. 3.0T motion-corrected single-shot phase sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) in free-breathing patients compared with conventional segmented breath-held LGE. J Cardiovasc Magn Reson 17 (Suppl 1), O61 (2015). https://doi.org/10.1186/1532-429X-17-S1-O61
Published:
DOI: https://doi.org/10.1186/1532-429X-17-S1-O61