Long-range response to transmission line disturbances in DC electricity grids

  • Regular Article
  • Published:
The European Physical Journal Special Topics Aims and scope Submit manuscript

Abstract

We consider a DC electricity grid composed of transmission lines connecting power generators and consumers at its nodes. The DC grid is described by nonlinear equations derived from Kirchhoff's law. For an initial distribution of consumed and generated power, and given transmission line conductances, we determine the geographical distribution of voltages at the nodes. Adjusting the generated power for the Joule heating losses, we then calculate the electrical power flow through the transmission lines. Next, we study the response of the grid to an additional transmission line between two sites of the grid and calculate the resulting change in the power flow distribution. This change is found to decay slowly in space, with a power of the distance from the additional line. We find the geographical distribution of the power transmission, when a link is added. With a finite probability the maximal load in the grid becomes larger when a transmission line is added, a phenomenon that is known as Braess’ paradox. We find that this phenomenon is more pronounced in a DC grid described by the nonlinear equations derived from Kirchhoff's law than in a linearised flow model studied previously in Ref. [1]. We observe furthermore that the increase in the load of the transmission lines due to an added line is of the same order of magnitude as Joule heating. Interestingly, for a fixed system size the load of the lines increases with the degree of disorder in the geographical distribution of consumers and producers.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D. Witthaut, M. Timme, Eur. Phys. J. B 86, 377 (2013)

    Article  ADS  Google Scholar 

  2. C.Y. Chung, L. Wang, F. Howell, P. Kundur, IEEE Trans. Power Syst. 19, 1387 (2004)

    Article  Google Scholar 

  3. S. Massoud Amin, A.M. Giacomoni, Fundamentals of Materials for Energy and Environmental Sustainability, edited by D.S. Ginley and D. Cahen (Cambridge University Press, 2011)

  4. M. Rohden, A. Sorge, M. Timme, D. Witthaut, Phys. Rev. Lett. 109, 064101 (2012)

    Article  ADS  Google Scholar 

  5. D. Witthaut, M. Timme, New J. Phys. 14, 083036 (2012)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stefan Kettemann.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Labavić, D., Suciu, R., Meyer-Ortmanns, H. et al. Long-range response to transmission line disturbances in DC electricity grids. Eur. Phys. J. Spec. Top. 223, 2517–2525 (2014). https://doi.org/10.1140/epjst/e2014-02273-0

Download citation

  • Received:

  • Revised:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1140/epjst/e2014-02273-0

Keywords

Navigation