1 Erratum to: Eur. Phys. J. C (2020) 80:1044 https://doi.org/10.1140/epjc/s10052-020-8420-x

The reference to the article is Manuscript ID EPJC-20-06-042 from the internal review perspective.

The reference to the article as published, is:

Akerib, D.S., Akerlof, C.W., Akimov, D.Y. et al. The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs. Eur. Phys. J. C 80, 1044 (2020). https://doi.org/10.1140/epjc/s10052-020-8420-x.

2 Items needing correction

2.1 Main body of the text

In Section 2.2.2 the Merrybent detector is referred to as having a relative efficiency of 110% – this should read 100%.

2.2 Table 1

The relative efficiency and face area values quoted in Table 1 are incorrect and the volume and mass of Roseberry are slightly larger than originally quoted. The table should read as follows:

Location

Detector

Type

V [cm\(^{3}\)]

M [kg]

Relative Efficiency (%)

Face Area [cm\(^{2}\)]

BUGS

Belmont

p-type

600

3.2

160

Merrybent

p-type

375

2.0

100

Lunehead

p-type

375

2.0

100

Roseberry

BEGe

195

1.0

65

Chaloner

BEGe

150

0.8

50

Lumpsey

SAGe well

263

1.4

LBNL

Merlin

n-type

430

2.2

115

BHUC

Maeve

p-type

375

2.0

85

Morgan

p-type

375

2.0

85

Mordred

n-type

253

1.3

60

SOLO

p-type

113

0.6

30

Alabama

Ge-II

p-type

260

1.4

60

Ge-III

p-type

406

2.2

105

Table 10 HPGe screening results
Table 11 ICP-MS screening results
Table 12 GDMS screening results
Table 13 NAA screening results
Table 14 Radon emanation results

2.3 Table 3

The uncertainties quoted in Table 3 are incorrect. The table should read as follows:

Detector

\({}^{238} {\hbox {U}}_{\mathrm {e}}\) (ppm)

\({}^{238} {\hbox {U}}_{\mathrm {l}}\) (ppm)

\({}^{232} {\hbox {Th}}_{\mathrm {e}}\) (ppm)

\({}^{232} {\hbox {Th}}_{\mathrm {l}}\) (ppm)

K (\(\%\))

Reference

8.5(1)

8.87(4)

12.1(1)

12.1(1)

2.82(1)

Merlin

8.92(9)

12.4(1)

12.4(1)

2.81(3)

Maeve

8.6(1)

8.6(1)

11.9(1)

11.9(1)

2.74(3)

Mordred

10.2(1)

7.92(5)

11.3(1)

11.3(2)

2.66(6)

SOLO

6.16(1)

9.94(1)

12.5(7)

2.91(1)

Chaloner

7.9(2)

8.73(5)

11.1(1)

11.1(1)

2.81(1)

Lunehead

8.5(1)

11.8(1)

11.8(1)

2.85(1)

Ge-II

11.4(15)

9.6(13)

12.2(17)

12(16)

3.4(4)

Ge-III

10.3(10)

9.2(9)

12.8(13)

12.1(12)

3.3(3)

Average

9.2(2)

7.61(3)

10.54(5)

11.9(1)

2.84(2)

Std. Dev.

1.26

0.98

0.84

0.46

0.25

2.4 Correcting values in the appendices

In the following tables, the items that have been updated or corrected are listed. The values that have been changed are highlighted in bold.