1 Introduction

It is known that the neutrino is the second most prevalent particle in the Universe. Significant progress has been achieved in neutrino physics in the last two decades. Successful observations of neutrino oscillations have confirmed that neutrinos are massive particles [1]. The majority of experimental results are in good agreement with the theory of three-neutrino oscillations. However several experiments and their results cannot be explained up to now. These results are called “anomalies”. The first so-called “gallium anomaly” was observed in solar neutrino experiments GALLEX and SAGE [2, 3]. The second anomaly result came from two beam experiments LSND and MiniBooNE [4, 5]. The latest result from MiniBooNE has increased the tension between oscillation theory and experimental data [6]. Recently, another anomaly has appeared after revisions of the reactor data [7]. One possible explanation for these anomalies might be hidden or uncounted uncertainties inside the experimental setup. Another possible solution is introducing one or several sterile flavors, which can mix with the standard active flavors. This is assuming that the sterile neutrino has a mass in the eV-scale. It should be noted that from the decay width of the Z-boson only three active flavors of neutrino may exist [8]. There are several possible schemes of mixing between sterile and active flavors of neutrino. The simplest scenario of mixing is the so called 3 + 1 scheme, where three active flavors of neutrino and one sterile state are involved. For this case it is reasonable to use the short baseline limit, when the leading contribution to oscillations comes only from sterile oscillation parameters (mixing angle and mass square difference). Other oscillation parameters will not impact the oscillation probability. For the 3+1 scheme, the survival oscillation probability of electron neutrino (anti-neutrino) can be written in the following form [9]:

$$\begin{aligned}&P(\nu _e\rightarrow \nu _e) \approx 1- \sin ^2(2\theta _{14})\nonumber \\&\quad \cdot \sin ^2\Big (1.27\cdot \Delta m^2_{41}\cdot \frac{L[\mathrm{m}]}{E[\mathrm{MeV}]}\Big ), \end{aligned}$$
(1.1)

where \(\theta _{14}\) is new neutrino mixing angle; \(\Delta m^2_{41}\) is the mass difference between the fourth and first neutrino mass states. Thus from Eq. (1.1) it follows that for eV-scale neutrinos the presence of sterile neutrinos can be detected as a deficit in total event rate and distortion in neutrino spectrum shape. As the oscillation frequency is relatively high in comparison with ordinary oscillations, short baseline experiments with high-intensity neutrino flux are required in searching for the sterile neutrino. All of the above conditions are fulfilled by the method of neutrino oscillometry. This method is described below.

2 The method of neutrino oscillometry

The core of this method is based on the concept of oscillation length and neutrino appearance-disappearance inside the detector fiducial volume. Including the sterile neutrino, the oscillation length can be expressed as [10]:

$$\begin{aligned} L_{\mathrm{osc}}=\frac{\pi E[\mathrm{MeV}]}{1.27\cdot \Delta m^2_{41}}. \end{aligned}$$
(2.1)

Here the oscillation length is the distance between two adjacent highs. Hence if the detector size is smaller than \(L_{\mathrm{osc}}\), the direct observation of the oscillation curve will be nearly impossible for the assumed experimental setup. As the neutrino is a weak interacting particle, the cross-section of its interaction with detector material is tiny. Therefore, the incoming neutrino flux should be well known and intensive enough to provide the shape measurements of the neutrino spectrum. Reactor or beam neutrinos (antineutrinos) are not fully suitable for neutrino oscillometry measurements. However a high-intensity handmade artificial source can be used in this case. Originally this idea was proposed for \(\theta _{13}\) measurement using the mono-energetic neutrino emitters and later for sterile neutrino searching [10,11,12,13]. The main candidate for the neutrino source is a well known isotope \(^{51}\mathrm{Cr}\), which has a few disadvantages: requires huge activity around 5 MCi in order to get rid of the overlapping solar background and a short life-time 27.7 days [2, 3, 14]. Later, antinetrino emitter was investigated [15]. Isotope \(^{144}\mathrm{Ce}\)\(^{144}\mathrm{Pr}\) was proposed as a possible source for sterile neutrino experiments. The SOX experiment from Borexino was aimed to implement this idea, but unfortunately it had a hard time with the source production and the project was canceled [16]. Hereinafter we focus on \(^{144}\mathrm{Ce}\)\(^{144}\mathrm{Pr}\) as an antineutrino source for the future solar neutrino experiment Jinping [17]. Another elegant suggestion is to use a short-lived isotope of \(^8{\mathrm{Li}}\) as an intensive antineutrino emitter [18]. The main proposal about this source is called IsoDAR and has been proposed for the KamLAND detector [19]. Besides, the method of neutrino oscillometry might provide a direct test in case of existence of more than one sterile neutrino flavor.

2.1 Antineutrino sources

2.1.1 \(^{144}\mathrm{Ce}\)\(^{144}\mathrm{Pr}\) source

As a source of \({\bar{\nu }}_e\), the decay chain of isotopes \(^{144}\mathrm{Ce} - ^{144}\mathrm{Pr}\) is a suitable option for an oscillometry experiment. The decay scheme is shown on the left panel of Fig. 1. The antineutrino energy spectrum of \(\mathrm {^{144}Pr}\) is continuous with the end point around 3 MeV and with an overall half-life of 285 days. About 48.5% of the emitted antineutrinos are at energies above the detection threshold of the inverse beta decay (IBD) reaction (the value of the threshold is 1.8 MeV) and thus can be used for the measurements. Based on the SOX calculation, the maximal source activity can reach 100 kCi. We assume two values of activity, 50 and 100 kCi, which depend on the experimental configuration.

Fig. 1
figure 1

The decay scheme of isotopes chain \(^{144}\mathrm{Ce}- ^{144}\mathrm{Pr}\) [15] and \(^8\mathrm{Li}\) isotope

The detailed information about the source production is presented in [15, 20]. As can be seen from the left decay scheme in Fig. 1, isotope of \(^{144}\mathrm{Pr}\) has the energetic 2185 keV (0.7%) gamma, which will demand to use a thick high Z-shielding material.

2.1.2 \(^8\mathrm{Li}\) source

Lithium-8 is a short-lived nuclide with half-lifetime 0.838 s and Q-value 16004.13 keV. \(^8\mathrm{Li}\) always decays to the exited state of \(^8\mathrm{Be}\) with \(Q_\beta = 12974\) keV [21]. The decay scheme is depicted on the right panel of Fig. 1. The antineutrino spectrum from \(^8\mathrm{Li}\) beta-decay is continuous with an end point of 13 MeV [22]. Based on the IsoDAR proposal, lithium-8 can be produced in two nuclear reactions: direct production \(p+^8\mathrm{Be}\rightarrow ^8\mathrm{Li}+2p\) and neutron capture by \(^7\mathrm{Li}\). A proton beam from a superconducting cyclotron (10 mA, 600 kW) hits a beryllium target, which is surrounded by sleeve with isotropically distributed lithium-7. We use an improved sleeve design, which is a cylinder with 1.3 m length and 1.2 m diameter [23]. This design allowed us to increase the \(^8\mathrm{Li}\) production up to 0.019 atoms per proton. The sleeve is put inside a container with layers of graphite, iron and concrete. It captures almost all escaping fast neutrons from the sleeve. More detailed information about sleeve and container design can be found [19].

2.2 Jinping facility as a detector for the oscillometry experiment

The Jinping neutrino detector will be located in the Jinping Mountain, Sichuan Province, China with a maximum overburden around 2400 meters [17]. It focuses on low energy neutrino and antineutrino measurements like solar, supernova and geo neutrinos. It has the lowest rate of muon flux \(\simeq 2 \times 10^{-10}~\mathrm {cm^{-2}\cdot s^{-1}}\) compared to other experiment facilities. The Jinping collaboration plans to build a 2 kton detector using slow liquid scintillator (LSc) [24]. This delays the scintillation process and thus separates from the Cherenkov light. This can significantly increase the background rejection capability using the particle identification method [24]. The inner detector volume will have a spherical shape with a radius around 8.2 meters. The expected energy resolution will be \(5\%/\sqrt{E[\mathrm{MeV}]}\). The Jinping detector will use PMTs with \(\sim 1\) ns TTS. This in turn will allow the Jinping detector to reach a position resolution of \(10~\mathrm{cm}/\sqrt{E[\mathrm{MeV}]}\) (this value is used in our calculations). In case of IsoDAR the position resolution should be enlarged due to additional contribution coming from initial source position uncertainty around 40 cm.

3 Layout of the experiment and numerical analysis

3.1 Experimental setup

3.1.1 Point-like \(^{144}\)Ce source

The scheme of the experiment is depicted in Fig. 2. There are two possible locations for point source, one at the center of the sphere (position I) and another at a distance 3 m from the edge of the detector (position II). The value of 3 meters is conservative and comparable to similar experimental proposals [16, 25]. The source at the detector center case gives a higher statistics but a shorter range of baseline. Technically, the more realistic case is when the source is outside of the detector. This configuration allows us to not break the structure of the detector’s inner volume. At both source positions the exposure time is assumed to be 450 days. Initial source activity will be 50 and 100 kCi for position I and position II respectively. The expected non-oscillation event rate is 28.5K and 73.8K for position I and position II respectively.

Fig. 2
figure 2

The schematic layout of the proposed experiment. Two positions for the radioactive source are assumed: at the center (position I) and outside of the detector (position II). Two fiducial volume cuts are applied. Inner cut with radius 100 cm and outer cut with width 70 cm. The yellow area is the active volume for position I, the yellow area plus the inner cut region is active volume for position II. The IsoDAR container is located further outside compared to position II. Only the outer cut is applied for this case

Concerning the background, as we consider the antineutrino emitter in the energy range the 1.8–3 MeV, the background will be geo-antineutrinos and antineutrinos from reactors. One of the main advantages of Jinping’s location is that it is far from any working nuclear power plants, which decreases the reactor flux significantly. Our estimation of the total background gives a value of \(\approx 100\) events per 450 days, which is two order of magnitude smaller than the expected signal rate. Considering these things the experimental setup can be considered free from IBD background.

Besides, as the \(^{144}\mathrm{Ce}\)\(^{144}\mathrm{Pr}\) chain has gamma radiation and the source activity is huge, so this experimental setup can also be used to search for dark matter and dark photons as proposed in ref. [26].

3.1.2 IsoDAR

Regarding the IsoDAR setup, since the container with the sleeve is much larger than a point source, there is only one option for this source to be installed outside of the detector’s active volume. The distance between beryllium target inside sleeve and the detector edge is 8 m. This value is comparable with KamLAND plus IsoDAR setup. The working time is assumed to be 5 years with 90% duty cycle. Only outer fiducial volume cut for the Jinping detector is applied for the \(^8\mathrm{Li}\) source. The expected amount of events in 5 years is \(1.76\cdot 10^6\), which is in two orders of magnitude larger than for a cerium source.

The \(^{8}\)Li production is exponentially decreasing as a function of the distance to the target center. Such a decreasing shape depends on the neutron capture cross section, which is known to a large extent. The proton beam can produce fast neutrons, which penetrate the sleeve. Those fast neutrons can be absorbed with the iron shielding surrounding the sleeve volume. Furthermore, a block can be placed downstream to the beam in order to completely remove the beam related neutron background.

3.2 Event rate calculation with toy MC

3.2.1 A point source like \(^{144}\)Ce

Analytically the equation for the expected event rate from a source with initial activity \(A_0\) can be expressed as [15]:

$$\begin{aligned}&N(L,E)=\iint \frac{A_0}{\lambda }(1-e^{-\lambda t_e})\nonumber \\&\rho \frac{\sigma _{\mathrm{IBD}}(E)\cdot S(E)\cdot p(L,E)}{4\pi L^2}dVdE, \end{aligned}$$
(3.1)

where L is distance between point source and a point inside the detector; E is the antineutrino energy; \(\lambda \) is a constant of radioactive decay; \(t_e\) is an exposure time (450 days); \(\rho \) is the density of free protons per cubic meter of LSc (\(6.4\cdot 10^{28}\) for LAB [27]); \(\sigma _{\mathrm{IBD}}\) is IBD cross-section [28]; S(E) is the spectrum shape of released antineutrinos [15], which is normalized to one; p(LE) is the oscillation probability Eq. (1.1).

The event rate calculation for position I is quite simple using Eq. (3.1), as it is a spherically symmetric case. However for a more complicated geometry like position II this method is not suitable and requires time consuming calculations. A much simpler approach uses MC toy events. Let’s connect the coordinate system with the source position, assuming that the source is a point. Then randomly distribute events inside 4D volume for i-th event we have four coordinates \((x_i,y_i,z_i,E_i)\). After that we count all events which are inside our spherical volume with energies in the range [1.8, 3] MeV. Each interesting MC event has its own weight. The weight can be easily calculated using next formula:

$$\begin{aligned} \omega _i=\frac{\sigma _{\mathrm{IBD}}(E_i)\cdot p(E_i, L_i)}{4\pi (x_i^2+y_i^2+z_i^2)}, \end{aligned}$$
(3.2)

where \(L_i^2=x_i^2+y_i^2+z_i^2\). Using the weight definition the desired event rate can be rewritten as:

$$\begin{aligned} N(L,E)= & {} {{\mathcal {C}}}\cdot \frac{\sum \omega _i}{N_{MC}^{in}}\int dV\int _{1.8}^{3.0}S(E)\nonumber \\= & {} {{\mathcal {C}}}\cdot \frac{\sum \omega _i}{N_{MC}^{in}}\cdot \frac{4}{3}\pi R^3\int _{1.8}^{3.0}S(E), \end{aligned}$$
(3.3)

where \({\mathcal {C}}\) carries all constants from Eq. (3.1); \(N_{MC}^{in}\) is the number of MC events inside the desired 4D volume. The second factor effectively represents the weighted event number per volume per energy.

In this way the MC approach demonstrates independence from geometry and allows us to easily apply event by event smearing, which is associated with energy and position resolutions. Also this allows us to use one dimensional chi-square function with only one variable L/E instead of the traditional two dimensional chi-square function with two separated variables L and E [15].

Fig. 3
figure 3

The top left panel corresponds to the non-oscillation event rate and two oscillation rates with the different values of oscillation parameters as a function of L/E variable (the right panel is for the IsoDAR case). The blue spectrum is based on current best fit values for the sterile neutrino [29]. The bottom left panel corresponds to the appropriated oscillation curves as a function of L/E variable (the right panel is for the IsoDAR case). The colored bands on the bottom pictures correspond to one sigma statistical uncertainty

The expected event rate for position II and appropriated oscillation curves are depicted in the left part of Fig. 3 and the right part corresponds to the lithium source. A second pair of oscillation parameters is an example which demonstrates larger oscillation structure. As can be seen from the bottom Fig. 3 smearing decreases the oscillation amplitude with the growth of L/E variable.

3.2.2 IsoDAR

As the IsoDAR is not a point-like source anymore, the baseline of each event depends on the location of the isotope. In Eq. (3.1) the term with activity should be substituted by the total number of antineutrinos produced after 5 years inside the sleeve volume. For the MC calculations all initial events should be randomly distributed inside the sleeve volume in the energy range [1.8; 12.9] MeV. The density of lithium-8 from the beryllium target to the sleeve’s edge is assumed to have an exponential distribution. Then the weight of i-th event can be written as:

$$\begin{aligned} \omega _i^s=\frac{\sigma _{\mathrm{IBD}}(E_i)\cdot p(E_i, L_{di})\cdot \rho _{8Li}(x_i,y_i,z_i)}{4\pi ((x_d-x_i)^2+(y_d-y_i)^2+(z_d-z_i)^2)}, \end{aligned}$$
(3.4)

where s stands for the sleeve case; \(\rho _{8Li}\) – exponential density of lithium atoms; \(x_d,y_d,z_d\) – coordinates of a point inside the detector; \(L_{di}\) – distance between points inside the sleeve and inside the detector. After that the Eq. (3.33.5) can be rewritten as:

$$\begin{aligned} N(L,E)={{\mathcal {C}}}\cdot \frac{\sum \omega _i^s}{N_{MC}^{in}}\cdot \frac{4}{3}\pi R^3\cdot V_s\int _{1.8}^{12.9}S(E), \end{aligned}$$
(3.5)

where \(V_s\) is sleeve volume. As the IsoDAR case has much more statistics, it allows us to measure oscillation parameters for sterile neutrinos with better precision than the case with a radioactive source.

3.3 Statistical evaluation

For the sensitivity definition to sterile neutrino parameters we follow the so-called classical method of calculating a confidence level. This method is based on the calculation of a \(\Delta \chi ^2\) function, which, as Wilks’ theorem predicts [30], should follow a chi-square distribution with a certain number of degrees of freedom (dof). The \(\Delta \chi ^2\) function should be marginalized with respect to two oscillation parameters: \(\theta _{14}\) and \(\Delta m^2_{41}\). Hence dof equals to 2. It is worth noting that the conditions required by Wilks’ theorem are usually not fulfilled in a sterile neutrino search [31]. Instead of the above mentioned method, a conventional way to set exclusion limits is the Feldman-Cousins (FC) procedure, as described in [32]. We have carried out MC simulations for \(\Delta \chi ^2\) using FC procedure and figured out that it approximately follows an analytical distribution of chi-square function with 2 dof. Thus it is justified to use an analytical assumption instead of the time consuming FC approach in our calculations. The correspondence between values of \(\Delta \chi ^2\) and a significance level was taken from the Table 39.2 in [8].

Using an approach similar to that used in [15], we define one dimensional chi-square function in the next form:

$$\begin{aligned}&\chi ^2=\sum \frac{(N_i^{\mathrm{obs}}-N_i^{\mathrm{pre}})^2}{N_i^{\mathrm{pre}}(1+N_i^{\mathrm{pre}}\cdot \sigma _b^2)}\nonumber \\&+\frac{\alpha ^2}{\sigma _\alpha ^2},\qquad N_i^{\mathrm{pre}}=(1+\alpha )S_i, \end{aligned}$$
(3.6)

where \(N_i^{\mathrm{obs}}\) – number of events with non-oscillation assumption; \(S_i\) – number of events with oscillation assumption; \(\sigma _b\) – uncorrelated bin to bin uncertainty, which includes all possible shape fluctuations. In our case we use 2% as value for \(\sigma _b\) (0% for IsoDAR case); \(\alpha \) – so-called nuisance parameter associated with the source activity; \(\sigma _\alpha \) – systematic error for the source activity (1.5% and 5% for radioactive source and IsoDAR respectively). The choice of quite a large value of \(\sigma _b\) for the radioactive source is used to overlap all possible systematic effects. It can be associated with energy scale (non-linearity of the energy response, which is typical for LSc detectors), spill in or out effect (leakage of IBD events near detector edge) etc. Summing up the above, the function (3.6) has two physical parameters (\(\theta _{14}\) and \(\Delta m^2_{41}\)) and one nuisance parameter (\(\alpha \)).

In general the sensitivity to sterile neutrinos can be calculated through the minimization of a \(\Delta \chi ^2\) function, which is given by:

$$\begin{aligned} \Delta \chi ^2=\chi _{\mathrm{fix}}^2-\chi _{\mathrm{min}}^2, \end{aligned}$$
(3.7)

where \(\chi _{\mathrm{fix}}^2\) uses a fixed pair of oscillation parameters; \(\chi _{\mathrm{min}}^2\) uses the best fit values for oscillation parameters. Both chi-square functions are identical to Eq. (3.6) and should be minimized through all nuisance parameters. In this analysis we use the so-called Asimov data set, consequently \(\chi _{\mathrm{min}}^2\) equals zero and \(\chi _{\mathrm{fix}}^2\) defines the sensitivity completely.

3.4 Systematic uncertainties treatment

Neutrino oscillation experiments mostly concern three systematic uncertainty sources: neutrino flux, neutrino interaction and the detection process. In the source-based sterile neutrino search in a LSc detector, as the neutrino IBD interaction cross-section is known precisely, the systematic uncertainties come from the other two main sources. They are classified into three categories and described as below.

The first one is the flux, which is related to the knowledge of the source neutrino emission precision. We assume a uniform 1.5% systematic uncertainty on the knowledge of the neutrino flux for the cerium source. We expect an increased knowledge of the neutrino emission from the radioactive source, which might appear from nuclear data measurements, at the time that the new generation of low-background neutrino experiments such as Jinping will start data taking. As of now, a 1.5% systematic uncertainty is adopted by various sensitivity studies performed for different source neutrino projects. A 5% systematic uncertainty is assumed for IsoDAR. It is based on the previous studies of this topic referring to [33].

Fig. 4
figure 4

The exclusion contours on a two-dimensional parameter space. 90% and 95% C.L. are shown for two possible setups. The left panel corresponds to the radioactive source and the right part corresponds to the IsoDAR. Combined reactor anomaly is also shown [7]. The stars indicate the current best fit value of the sterile neutrino [29], the best value of the reactor antineutrino anomaly (RAA) [7], and the best fit result of the Neutrino-4 experiment [35, 36] from left to right respectively

Fig. 5
figure 5

The sensitivity of the experiment as a function of different parameters. Panel A corresponds to the distance between the source and the detector edge. Panel B corresponds to the energy resolution of Jinping. Panel C corresponds to the position resolution of Jinping. Panel D corresponds to the source activity. Panel E corresponds to the value of bin to bin uncertainty. Panel F corresponds to the length of outer cut. Assumed oscillation parameters \(\sin ^2(2\theta _{14})=0.1\), \(\Delta m^2_{41}=1~\mathrm{eV}^2\)

The second is the detection efficiency uncertainty. We assume a 90% efficiency across the energy range for all neutrino detection with a systematic uncertainty along the full energy range for both sources. Usually this systematic uncertainty is at level of one percent. Since this systematic error is fully correlated with the flux uncertainty we decided not to double this. The \(\sigma _{\alpha }\) accounts for this effect. This detection efficiency includes both prompt positron and delayed neutron detection. A spill in/out effect can happen when the interaction vertex is inside a volume while the neutron capture is outside the fiducial volume. We examined the spill effect and it turns out to be negligible. As the neutron moves with a distance typically less than a few centimeters, the spill effect only takes place in the boundary shell around 20 cm size. With the radioactive source at a distance 2.3 m away from the detector surface, the overall spill-in effect gives 3% more events at the outer 20 cm shell. In the case of the source located in the center of the spherical detector, we will need a fiducial volume cut for the inner sphere around the source. The spill-in effect occurring here provides us 19% more events for the first inner 20 cm shell. These spill-in effects have been included and tested. There was no noticeable impact from them considering a 100% uncertainty on those spill-in events.

The last one is the energy scale and resolution uncertainties. The energy resolution is based on the Jinping proposal, which is 5% at 1 MeV. We tested the sensitivity with 5%, 8% and 10% resolutions. That result guides us to ignore the resolution systematic uncertainty for this case. Regarding the energy scale uncertainty, 1% uncertainty is assumed based on the Daya Bay results [34]. Two independent approaches have been performed to cross check the energy scale uncertainty. The first of them is the shifting of the reconstructed neutrino energy event by event with \(1\sigma \) uncertainty of 1%. This might be computing intensive because of the fact that in each fitting iteration, the energy scale parameter changes and all events should be updated based on the current energy scale parameter. The second is to apply an energy scale uncertainty as a 2% bin-to-bin uncorrelated error (\(\sigma _b\)). The results from both approaches are consistent. Therefore, the results shown in this paper have been obtained using the second approach due to simplicity and calculation speed. Besides it, an additional contribution to the shape error budget may come from several forbidden transitions in \(^{144}{\mathrm{Pr}}\). Thus it will require an appropriate beta-spectroscopic measurement using for instance cerium nitrate samples to constrain this effect. A possible solution is described in [25]. It should be mentioned that lithium source shape uncertainties are much smaller, so there are no reasons to use this \(\sigma _b\) together with IsoDAR.

4 Results and discussion

Following the statistical method mentioned above, the general sensitivity to sterile neutrinos can be represented as a two-dimensional exclusion plot. For comparison, the SOX and JUNO results are also drawn on the left panel of Fig. 4, the KamLAND and JUNO plus IsoDAR results are drawn on the right panel of Fig. 4. As can be seen, all currently interesting regions for sterile neutrino searching are covered if we consider position I. For position II, some part of the RAA and best fit are still not fully covered. Recently, possible reevaluations of the RAA are discussed in [37, 38]. As expected, the IsoDAR setup has better sensitivity and can investigate wider ranges of the oscillation parameter phase space than the radioactive source. Both setups can validate or reject the measured result from the Neutrino-4 experiment [35, 36]. To avoid any problems associated with heterogeneity of position and energy resolution inside the detector we apply a fiducial volume cut: an outer cut 70 cm for both positions of the radioactive source and IsoDAR, and an inner cut 100 cm only for position I for the radioactive source.

In addition, we investigated the behavior of the sensitivity  (3.6) as a function of different parameters such as energy resolution, position resolution, distance between source and the detector edge for position II, source activity, bin to bin uncertainty and the length of outer cut. All results are summarized in Fig. 5. The source should be located as close as possible to the detector edge for position II. Energy resolution is an important parameter for this analysis, as larger values for the energy resolution erodes the spectral shape and causes the loss of information. Spectrum shape should be known precisely. And position resolution of the detector should not be excellent for oscillometry measurements. All these conclusions are valid for setup with the IsoDAR lithium source.

5 Conclusion

Our research has demonstrated the success of using a powerful antineutrino radioactive source and the IsoDAR source for the sterile neutrino search. It is important to measure the first few units of L/E, because the waves of oscillation curve fade out very quickly due to smearing. The method of neutrino oscillometry allows us to observe a whole oscillation L/E spectrum inside the detector with the sterile neutrino hypothesis. A high-intensity source and a large detector are needed to limit the statistical fluctuation and certain knowledge of the experiment performance is needed in order to control the systematic uncertinaties. In comparison to the reactor experiments, this method is free from the large uncertainty of the reactor spectrum prediction.

We have shown that the combination of a hand-made source and the Jinping facility can potentially provide a remarkable coverage of the sterile neutrino oscillation parameter phase space, hence an exploration on the previous sterile neutrino anomaly results. Besides, this setup will provide us a clear test of the Neutrino-4 results. Therefore, it may be a considerable part of the Jinping’s scientific programs. The implementation of such an experiment may also deliver a conclusive result to the light sterile neutrino search.