Skip to main content
Log in

An investigation into the sensitivity of various albedo neutron dosimeters aimed at correcting the readings

  • Radiobiology, Ecology, and Nuclear Medicine
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

The results of an experimental determination of the sensitivity of three types of individual neutron albedo dosimeters in neutron reference fields on the basis of radionuclide sources and at the top concrete shielding of the U-70 accelerator are presented. The results show that the ratios between the responses of the albedo dosimeters designed earlier at the Joint Institute for Nuclear Research (the albedo dosimeter (AD) and the multicomponent dosimeter (MD)) and the currently used DVGN-01 dosimeter are constant within 25% in a wide range of neutron energy. This fact makes it possible to use the results of measuring the AD and MD responses obtained earlier in neutron fields of nuclear-physical installations at the Joint Institute for Nuclear Research (JINR) for the correction of DVGN-01 dosimeter measurement results to apply it to personal radiation monitoring (PRM) at these installations. The correction factors for DVGN-01 measurement results are found and recommended to be used in PRM for most JINR installations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. V. Sannikov, et al., “Individual Dosimeter of Mixed Radiation DVGN-01: Design and Investigation of Properties,” Preprint No. IFVE-6 ORI (Protvino, 2005).

  2. L. G. Beskrovnaya, E. A. Goroshkova, and Yu. V. Mokrov, “An Investigation into the Accuracy of the Albedo Dosimeter DVGN-01 in Measuring Personnel Irradiation Doses in the Fields of Neutron Radiation at Nuclear Power Installations of the Joint Institute for Nuclear Research,” Phys. Part. Nucl. Lett. 7, 212 (2010).

    Article  Google Scholar 

  3. Automatic Compex of Individual Dosimeter Control AKIDK-301, Operating Manual (Angarsk, 2007).

  4. G. Ya. Kaskanov et al., “Sensitivity of Albedo Dosimeter with Thermoluminescent Detectors to Neutrons of Different Energetic Spectra,” Soobshch. OIYaI 16-84-804 (Dubna, 1984).

  5. E. Piesch and B. Burghardt, in Proceedings of the 4th International Conference on Luminescence Dosimetry, Krakov, Poland (1974), vol. 3, p. 1123.

    Google Scholar 

  6. Yu. V. Mokrov, “Development of Methods and Means of Metrological Providing of Radiation Control of Neutron Radiation from Accelerators and Pulsed Reactors,” Candidate’s Dissertation in Technical Science (Moscow, 1999).

  7. MU 2.6.2.25-2000, “Methodical Guide. Dosimeter Control of External Professional Irradiation. General Requirements,” in Methodical Providing of Radiation Control in Companies (Ministerstvo RF Atom. Energii, Ministerstvo Zdravookhraneniya RF, Feder. Uprav. Mediko-Biol. Ekstrem. Problem, Moscow, 2001), vol. 1, p. 81 [in Russian].

    Google Scholar 

  8. A. I. Abrosimov, et al., “Dose Characteristics of IHEP Reference Neutron Fields,” IHEP Preprint No. 93-43 (Protvino, 1993).

  9. A. G. Alekseev and P. F. Maslyaev, “Comparative Experiments of Individual Electronic Direct-Indicative Neutron Dosimeters,” Appar. Novosti Rad. Izmer., no. 1, 54–59 (2008).

  10. A. G. Alekseev and S. A. Kharlampiev, “Dosimetric Characteristics of the IHEP Neutron Reference Fields,” Rad. Protect. Dosim. 70, 341–344 (1997).

    Google Scholar 

  11. G. I. Krupnyi et al., “To the Question of Production of High Energy Basic Field of Neutron Radiation,” Preprint No. IFVE 2009-5 (Protvino, 2009).

  12. V. E. Aleinikov, L. G. Beskrovnaya, and Yu. V. Mokrov, “Study the Measuring Possibility by 10 W-Neutron Counter in Combined Moderator of Neutron Ambient Dose in the Fields of Nuclear Facilities of JINR,” Soobshch. OIYaI No. R16-2008-46 (Dubna, 2008).

  13. E. V. Kos’yanenko, et al., “Spectra and Dosimetric Properties of Neutron Fields on Personnel Workplaces on Mining and Chemical Plant,” Preprint No. IFVE 2008-22 ORI (Protvino, 2008).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © A.G. Alekseev, Yu.V. Mokrov, S.V. Morozova, 2012, published in Pis’ma v Zhurnal Fizika Elementarnykh Chastits i Atomnogo Yadra, 2012, No. 2 (172), pp. 312–327.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Alekseev, A.G., Mokrov, Y.V. & Morozova, S.V. An investigation into the sensitivity of various albedo neutron dosimeters aimed at correcting the readings. Phys. Part. Nuclei Lett. 9, 192–201 (2012). https://doi.org/10.1134/S1547477112020021

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1547477112020021

Keywords

Navigation