Skip to main content
Log in

The decrease of light yield collection for scintillation counters of CDF muon trigger over time

  • Methods of Physical Experiment
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

The muon system of CDF spectrometer plays an important role in investigating processes with heavy quarks. The efficient functioning of scintillation counters, which comprise a considerable part of the CFD muon trigger, is a necessary condition for obtaining experimental data. The results of long-term measurements of the light yield, collected far from the photomultiplier end of the scintillation plate for different types of counters in order to predict the period of their effective operation in experiments, are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. The CDF II Collab., The CDF II Detector Technical Design Report. Fermilab-Pub-96/390-E (1996).

  2. A. Artikov et al., “Design and Construction of New Central and Forward Muon Counters for CDF II,” Nucl. Instrum. Methods Phys. Res. A 538, 358–371 (2005).

    Article  ADS  Google Scholar 

  3. A. Artikov et al., “New-Generation Large-Area Muon Scintillation Counters with Wavelength Shifter Fiber Readout for SDF II,” Pis’ma Fiz. Elem. Chastits At. Yadra 3(3), 81–102 (2006) [Phys. Part. Nucl. Lett. 3, 188 (2006)].

    Google Scholar 

  4. S. Cabrera et al., “Making the Most of Aging Scintillator,” Nucl. Instrum. Methods Phys. Res. A 453, 245–248 (2000).

    Article  ADS  Google Scholar 

  5. P. Giromini et al., “The Central Muon Extension Scintillators (CSX),” CDF Note 3989 (1996).

  6. E. H. Bellamy et al., “Absolute Calibration and Monitoring of a Spectrometric Channel Using a Photomultiplier,” Nucl. Instrum. Methods Phys. Res. A 339, 468–476 (1994).

    Article  ADS  Google Scholar 

  7. A. Artikov et al., “On the Aging of the CSP and CSX Counters,” CDF Note 7033 (2004).

  8. I. Chirikov-Zorin et al., “Method for Precise Analysis of the Metal Package Photomultiplier Single Photoelectron Spectra,” Nucl. Instrum. Methods Phys. Res. A 456, 310–324 (2001).

    Article  ADS  Google Scholar 

  9. J. Fernandez et al., “Test of the Central Muon Extension Scintillators (CSX),” CDF Note 5006 (1999).

  10. A. Artikov et al., “Properties of the Ukraine Polystyrene- Based Plastic Scintillator UPS 923A,” Nucl. Instrum. Methods Phys. Res. A 555, 125–131 (2005).

    Article  ADS  Google Scholar 

  11. A. Artikov et al., “The ‘Miniskirt’ Sounter Array at SDFII,” Pis’ma Fiz. Elem. Chastits At. Yadra 5(5), 25–39 (2002).

    Google Scholar 

  12. E. H. Bellamy et al., “Test of Long Scintillation Counters For Large Supercollider Detectors,” Nucl. Instrum. Methods Phys. Res. A 343, 484–488 (1994).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © A.M. Artikov, O.E. Pukhov, D. Chokheli, D. Pauletta, 2009, published in Pis’ma v Zhurnal Fizika Elementarnykh Chastits i Atomnogo Yadra, 2009, No. 2 (150), pp. 217–232.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Artikov, A.M., Pukhov, O.E., Chokheli, D. et al. The decrease of light yield collection for scintillation counters of CDF muon trigger over time. Phys. Part. Nuclei Lett. 6, 134–144 (2009). https://doi.org/10.1134/S154747710902006X

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S154747710902006X

PACS numbers

Navigation