Application of 10B counter with moderator for neutron ambient dose equivalent measurement during radiation monitoring at joint institute for nuclear research

  • Radiobiology, Ecology, and Nuclear Medicine
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

The results of an investigation into the possibility of applying a device based on a 10B neutron counter (CHM-14) with a polyethylene moderator as the dosimeter of neutron ambient dose equivalent H*(10) in radiation fields of nuclear physics installations at the Joint Institute for Nuclear Research (JINR) are presented. It is shown that the device can be used as the dosimeter of this quantity in the neutron energy range from 0.4 eV to 20 MeV with an error no larger than 30% due to the difference between the energy dependence of its response and the energy dependence of the neutron ambient dose equivalent. Applying the correction coefficients allows one to extend the energy range of neutron dose H*(10) measurement to hundreds MeV. The error due to the anisotropy of the device response does not exceed 35%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. SP 2.6.1.758-99. Standards of Radiation Safety (NRB-99): Hygiene Norms (Centre of Sanitary Epidemiological Rate Setting, Hygiene Certification and Assessment of Russ. Minzdrav, Moscow, 1999), p. 116 [in Russian].

  2. Radiation Safety. ICRP 1990 Recommendations (Energoatomizdat, Moscow, 1994), Chs. 1, 2 [in Russian].

  3. Assessment of Occupational Exposure Due to External Sources of Radiation, IAEA Safety Guide (IAEA, Vienna, 1999).

  4. “Conversion Coefficients for use in Radiological Protection Against External Radiation,” ICRU Report 57 (Bethesda, 1998).

  5. A. V. Sannikov and E. N. Savitskaya, “Ambient Dose Equivalent Conversion Factors for High Energy Neutrons Based on the ICRP 60 Recommendations,” Radiat. Prot. Dosim. 70, 383–386 (1997).

    Google Scholar 

  6. V. N. Buchnev et al., “Sensitivity Estimation of SNM-14 with Combined Moderator at 14.2 MeV Neutron Energy,” Soobshch. OIYaI R3-85-428 (Dubna, 1985).

  7. V. N. Buchnev, M. M. Komochkov, and Yu. V. Mokrov, “Energy Dependence of Sensitivity and Accuracy of Some Dosimeters of Neutrons,” Soobshch. OIYaI R16-86-491 (Dubna, 1986).

  8. G. A. Komendantova, M. M. Komochkov, M. I. Salatskaya, and V. I. Tsovbun, “Adequacy Study of Individual Photoemulsion Dosimeters Readings to Equivalent Neutron Dose near Heavy Ion Accelerators,” Preprint OIYaI 16-12858 (Dubna, 1979).

  9. V. A. Arkhipov, L. G. Beskrovnaya, M. M. Komochkov, and M. I. Salatskaya, “Adequacy study of Photoemulsion and Scintillator Detector Readings to Equivalent Dose in Fields of Diffuse Radiation of IBR-30,” Soobshch. OIYaI 16-11817 (Dubna, 1978).

  10. V. A. Arkhipov, M. M. Komochkov, S. V. Kulikov, and A. Stpichinski, “Physical Start-up of IBR-2 Reactor. Measurment of Neutron Spectrum of Leak,” Soobshch. OIYaI R13-12466 (Dubna, 1979).

  11. V. E. Aleinikov, V. P. Bamblevskii, M. M. Komochkov, et al., “Reference Fields of Neutron Radiation for Metrological Support of Radiation Monitoring,” Preprint OIYaI R16-92-36 (Dubna, 1992).

  12. “Compendium of Neutron Spectra and Detector Response for Radiation Protection Purpose,” Techn. Rep. Ser. No. 403 (IAEA, Vienna, 2001).

  13. V. E. Aleinikov, Candidate’s Dissertation in Mathematical Physics (OIYaI, Dubna, 1978).

    Google Scholar 

  14. V. E. Aleinikov, M. M. Komochkov, and V. P. Kryuchkov, “Experimental Test of Simulation Methods of Proton Accelerator Shielding,” Preprint OIYaI R16-8179 (Dubna, 1974).

  15. V. E. Aleinikov, V. P. Gerdt, and M. M. Komochkov, “Neutron Energy Spectra behind Shielding of High Energy Proton Accelerators,” Preprint OIYaI R16-8176 (Dubna, 1974).

  16. V. E. Aleinikov, V. P. Gerdt, M. A. Ignatenko, and V. I. Tsovbun, “Radiation Situation near Channel of Slow Proton Ejection from Synchrophasotron at 10 GeV Energy,” Soobshch. OIYaI 16-8583 (Dubna, 1975).

  17. V. E. Aleinikov, L. G. Beskrovnaya, and Yu. V. Mokrov, “On Possibility to Measure by Neutron 10B-Counter with Combined Moderator of Neutron Ambient Dose in Radiation Fields of JINR Nuclear-Physical Installations,” Soobshch. OIYaI R16-2008-46 (Dubna, 2008).

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © V.E. Aleynikov, L.G. Beskrovnaia, Yu.V. Mokrov, 2009, published in Pis’ma v Zhurnal Fizika Elementarnykh Chastits i Atomnogo Yadra, 2009, No. 1 (149), pp. 124–133.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Aleynikov, V.E., Beskrovnaia, L.G. & Mokrov, Y.V. Application of 10B counter with moderator for neutron ambient dose equivalent measurement during radiation monitoring at joint institute for nuclear research. Phys. Part. Nuclei Lett. 6, 78–83 (2009). https://doi.org/10.1134/S1547477109010129

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1547477109010129

PACS numbers

Navigation