Skip to main content
Log in

NR activity in the accelerating cavities development and study for ILC positron source parameters

  • Physics and Technique of Accelerators
  • Published:
Physics of Particles and Nuclei Letters Aims and scope Submit manuscript

Abstract

The critical part of the normal conducting (NC) positron preaccelerator (PPA) at the ILC positron source (PS) are capture sections that should operate with an accelerating gradient of up to 15 MV/m in combination with long RF pulse (∼1 ms). Developed at the Institute of Nuclear Research (INR) and now being constructed at DESY, the CDS booster cavity for the Photo Injector Test facility, DESY, Zeuthen, will operate under the same conditions and is a full-scale, high-RF-power prototype of the PS capture cavities. Cavity construction status and results of cavity tuning at a low RF level are presented. Other features of the standing wave cavities for the PPA, such as RF pulsed heating, advanced cooling, and beam loading, are discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Conceptual Design of a Positron Injector for the TESLA Linear Collider, Ed. by K. Floettmann and V. Paramonov, TESLA 99-14, TESLA 2000-12 (Hamburg, DESY).

  2. ILC Conceptual Design Report, http://www.linearcollider.org

  3. V. Moiseev et al., “Comparioson of SW and TW Operations for a Positron Pre-Accelerator in the TESLA Linear Collider,” in Proc. of EPAC2000 (2000), p. 842.

  4. V. V. Paramonov, “The Cut Disk Structure for High Energy Linacs,” in Proc. of 1997 PAC (1998) 3, p. 2962.

    Google Scholar 

  5. N. I. Brusova, A. I. Kvasha, et al., “Design Parameters of the Normal Conducting Booster Cavity for the PITZ-2 Test Stand,” in Proc. of LINAC 2004 (2004), p. 204.

  6. M. Krasilnikov, V. Paramonov, et al., “The PITZ Booster Cavity-a Prototype for the ILC Positron Injector Cavities,” in PAC 2005 (2005), p. 1030.

  7. J. W. Wang et al., “Studies of Room Temperature Structures for the ILC Positron Source,” in Proc. of PAC 2005 (2005), p. 2827.

  8. V. V. Paramonov and A. K. Skasyrskaya, “Pulsed RF Heating Simulations in Normal Conducting L-Band Cavities,” TESLA-FEL Report 2007-04 (DESY, Hamburg, 2007).

    Google Scholar 

  9. V. V. Paramonov and K. Floettmann, “Beam-Loading Effect in the Normal-Conducting ILC Positron Source Pre-Accelerator,” in Proc. of 2006 Linac (2006), p. 355.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. V. Paramonov.

Additional information

The text was submitted by the authors in English.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Paramonov, V.V., Kravchuk, L.V., Moiseev, V.A. et al. NR activity in the accelerating cavities development and study for ILC positron source parameters. Phys. Part. Nuclei Lett. 5, 593–596 (2008). https://doi.org/10.1134/S1547477108070121

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1547477108070121

PACS numbers

Navigation