Abstract

A new method is proposed and verified, according to which the resolving power of an ion mobility increment spectrometer (IMIS) can be increased by applying a voltage of certain fixed frequency (ripple voltage) to the output electrode. The results of computer simulations and the experiment showed that this method leads to narrowing of the interval of compensating voltages for which ions can be transmitted via the IMIS, which improves the resolution at the expense of a decrease in the signal intensity. For protonated diethylamine ions, the proposed method provides for a more than twofold improvement of the resolution at a 40% decrease in the signal intensity. The application of a ripple voltage to the output electrode retains low diffuse losses of ions in the analytical gap.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. I. A. Buryakov, Talanta 61, 369 (2003).

    Article  Google Scholar 

  2. G. A. Eiceman, B. Tadjikov, E. Krylov, et al., J. Chromatogr. A 917, 205 (2001).

    Article  Google Scholar 

  3. R. Guevremont, J. Chromatogr. A 1058, 3 (2004).

    Google Scholar 

  4. A. Shvartsburg, F. Li, K. Tang, and R. Smith, Anal. Chem. 78, 3706 (2006).

    Article  Google Scholar 

  5. E. V. Krylov, Zh. Tekh. Fiz. 69(1), 124 (1999) [Tech. Phys. 44, 113 (1999)].

    Google Scholar 

  6. A. Shvartsburg, K. Tang, and R. Smith, J. Am. Soc. Mass Spectrom. 16, 1447 (2005).

    Article  Google Scholar 

  7. V. V. Pervukhin and D. G. Sheven’, Zh. Tekh. Fiz. 78(1), 114 (2008) [Tech. Phys. 53, 110 (2008)].

    Google Scholar 

  8. D. A. Dahl, SIMION 3D Version 6.0 User’s Manual (1995); http://citeseer.ist.psu.edu/article/dah195users.html.

  9. R. Guevremont, G. Thekkadath, and C. K. Hilton, J. Am. Soc. Mass Spectrom. 16, 948 (2005).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. V. Pervukhin.

Additional information

Original Russian Text © V.V. Pervukhin, D.G. Sheven’ , 2008, published in Pis’ma v Zhurnal Tekhnicheskĭ Fiziki, 2008, Vol. 34, No. 22, pp. 57–63.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pervukhin, V.V., Sheven, D.G. Increasing the resolution of ion mobility increment spectrometers using the ripple voltage. Tech. Phys. Lett. 34, 977–980 (2008). https://doi.org/10.1134/S1063785008110230

Download citation

  • Revised:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1063785008110230

PACS numbers

Navigation