Optimized electron–optical system of a static mass-spectrometer for simultaneous isotopic and chemical analysis

  • Electrophysics, Electron and Ion Beams, Physics of Accelerators
  • Published:
Technical Physics Aims and scope Submit manuscript

Abstract

A new approach to control the linear dimensions of analytical electrophysical systems is suggested. This approach uses the lens properties of electron–optical elements with a curvilinear axis. It is shown that such an approach can be effectively applied, in particular, to synthesize ion–optical systems (IOSs) for static magnetic mass spectrometers and can be implemented owing to off-axis fundamental points, the “poles” of an electron–optical system, introduced earlier by one of the authors. The capabilities of the new approach are demonstrated with the synthesis of the IOS of a static mass spectrometer dedicated for isotopic and chemical analysis with an increased resolution. A new IOS not only provides desired high ion–optical parameters at decreased dimensions of the mass spectrometer as a whole but also makes it possible to loosen requirements for the manufacturing accuracy of IOS main elements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. N. F. Barber, Proc. Leeds Philos. Soc. 2, 427 (1933).

    Google Scholar 

  2. R. Herzog, Z. Phys. 89, 447 (1934).

    Article  ADS  Google Scholar 

  3. D. Paul, G. Skrzypek, and I. Forizs, Rapid Commun. Mass Spectrom. 21, 3006 (2007).

    Article  Google Scholar 

  4. V. D. Sachenko, Nauchn. Priborostr. 22, 66 (2012).

    Google Scholar 

  5. V. D. Sachenko, L. N. Gall, and N. R. Gall, in Proceedings of the 19th International Mass Spectrometry Conference (IMSC), Kyoto, 2012, p. 348.

  6. V. M. Lebedev, Nuclear Fuel Cycle: Technology, Safety, and Economics (Energoatomizdat, Moscow, 2005).

    Google Scholar 

  7. R. N. Gall, Sov. Phys. Tech. Phys. 14, 263 (1969).

    ADS  Google Scholar 

  8. L. N. Gall’, V. D. Sachenko, V. A. Lednev, A. S. Berdnikov, V. A. Vasil’ev, and A. P. Ivanov, Nauchn. Priborostr. 11 (4), 21 (2001).

    Google Scholar 

  9. N. R. Kuzelev, A. S. Shtan’, G. I. Kir’yanov, L. N. Gall’, A. P. Knutarev, G. S. Solov’ev, A. V. Saprygin, V. A. Kalashnikov, D. V. Novikov, A. B. Maleev, V. A. Borodin, V. G. Gorbunov, Zh. A. Savina, and A. P. Ivanov, Mass-Spektrometr. 6, 253 (2009).

    Google Scholar 

  10. Handbook of Nuclear Chemistry, Vol. 1: Basics of Nuclear Science, Ed. by Attila Vértes, Sándor Nagy, Zoltán Klencsár, Rezso György Lovas, and Frank Rösch (Springer Science–Business Media, 2010).

  11. D. Tuttas and J. B. Schwieters, Advances in High Precision Isotope Ratio Measurements of Calcium Using TIMS (Thermo Fisher Scientific, Bremen, 2012), Application Note: 30018, pp. 1–16.

    Google Scholar 

  12. V. T. Kogan, G. Yu. Gladkov, and O. S. Viktorova, Tech. Phys. 56, 492 (2001).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to L. N. Gall’.

Additional information

Original Russian Text © L.N. Gall’, S.V. Masyukevich, V.D. Sachenko, N.R. Gall’, 2016, published in Zhurnal Tekhnicheskoi Fiziki, 2016, Vol. 61, No. 1, pp. 116–120.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gall’, L.N., Masyukevich, S.V., Sachenko, V.D. et al. Optimized electron–optical system of a static mass-spectrometer for simultaneous isotopic and chemical analysis. Tech. Phys. 61, 114–118 (2016). https://doi.org/10.1134/S1063784216010096

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1063784216010096

Keywords

Navigation