Abstract

The functioning of the scanning probe microscope cantilever with a metal-carbon whisker at the top is studied. Metal-carbon whiskers grown by focused ion beam deposition in the presence of precursor gases have an aspect ratio in the range α = 10−200 and hold shape upon multiple scanning in the constant force mode. The advantage of probes with whiskers at the top in examining rough surfaces with vertical walls and narrow grooves is demonstrated experimentally. At high α, the scanning probe microscope is found to operate unstably, because the lateral surface of the whisker interacts with the specimen. It is shown that the axis of the whisker should be set normally to the specimen’s surface for the microscope to operate reliably at high aspect ratios.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. S. S. Branner, Science 128, 9 (1958).

    Article  Google Scholar 

  2. B. O. Kucukyildirim, A. Akdogan Eker, and B. Eker, Int. J. Arts Sciences 3, 18 (2009).

    Google Scholar 

  3. A. A. Evstrapov, I. S. Mukhin, I. V. Kukhtevich, and A. S. Bukatin, Tech. Phys. Lett. 37, 956 (2011).

    Article  ADS  Google Scholar 

  4. W. F. van Dorp and C. W. Hagen, J. Appl. Phys. 104, 081301 (2008).

    Article  ADS  Google Scholar 

  5. I. S. Mukhin, M. S. Mukhin, A. V. Feklistov, and A. O. Golubok, Nauchn. Priborostr. 21(3), 23 (2011).

    Google Scholar 

  6. E. I. Starovoitov, Strength of Materials (Fizmatlit, Moscow, 2008), p. 384.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. V. Levichev.

Additional information

Original Russian Text © V.V. Levichev, M.V. Zhukov, I.S. Mukhin, A.I. Denisyuk, A.O. Golubok, 2013, published in Zhurnal Tekhnicheskoi Fiziki, 2013, Vol. 83, No. 7, pp. 115–120.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Levichev, V.V., Zhukov, M.V., Mukhin, I.S. et al. On the operating stability of a scanning force microscope with a nanowhisker at the top of the probe. Tech. Phys. 58, 1043–1047 (2013). https://doi.org/10.1134/S1063784213070128

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1063784213070128

Keywords

Navigation