Abstract
The variation of the X-ray intensity has been investigated with the Pyrex and quartz insulators surface contamination in a 4-kJ plasma focus device with argon gas at 11.5-kV charging voltage. Elemental analysis (EDAX) showed that the Cu evaporated from the electrode material and was deposited on the sleeve surface improves the breakdown conditions. A small level of sleeve contamination by copper is found to be essential for good focusing action and high HXR intensity. The SEM imaging showed the grain-type structure of Cu formed on the surface and it changed the surface property. Resistance measurements of original and coated Pyrex surface proved that the copper deposition on the sleeve surface will reduce its resistance as compared to the almost infinitely large resistance of the uncontaminated sleeve. As the contamination is surpassed to some critical level, the HXR intensity from the device is deteriorated.
Similar content being viewed by others
References
J. W. Mather, Phys. Fluids 8, 336 (1965).
N. V. Filippov, T. I. Filippova, and V. P. Vinogradov, Nucl. Fusion Suppl., No. 2, 557 (1962).
H. Herold, A. Jerzykiewicz, M. Sadowski, and H. Schmidt, Nucl. Fusion 29, 1255 (1989).
J. Moreno, P. Silva, and L. Soto, Plasma Sources Sci. Technol. 12, 39 (2003).
A. Blagoev and V. Yordanov, Plasma Phys. Controlled Fusion 51, 1 (2009).
M. Zakaullah, T. J. Baig, S. Beg, and G. Murtaza, Phys. Lett. 39, 1374 (1989).
J. N. Feugeas and G. Grigioni, J. Phys. D 30, 2026 (1997).
J. Feugeas, E. Llonch, C. O. de Gonzalez, and G. Galambos, J. Appl. Phys. 64, 2646 (1988).
V. Nardi, W. H. Bostick, J. Feugeas, et al., in Proceedings of the 7th IAEA Conference on Plasma Physics and Controlled Nuclear Fusion Research, Innsbruck, 1978 (IAEA, Vienna, 1979), Vol. 2, p. 143.
M. Zakaullah, A. Waheed, S. Ahmad, and S. Hussain, Plasma Sources Sci. Technol. 12, 443 (2003).
M. Habibi, R. Amrollahi, and M. Attaran, J. Fusion Energy 28, 130 (2009).
M. Habibi, R. Amrollahi, M. Attaran, and R. Etaati, Plasma Dev. Oper. 16, 163 (2008).
R. Baghdadi, G. R. Etaati, M. Habibi, et al., J. Fusion Energy 30, 545 (2011).
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
Rights and permissions
About this article
Cite this article
Habibi, M., Sharifi, R. & Amrollahi, R. Study of Pyrex and quartz insulators contamination effect on the X-ray intensity in a 4-kJ plasma focus device. Plasma Phys. Rep. 39, 999–1003 (2013). https://doi.org/10.1134/S1063780X14020056
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1063780X14020056