Skip to main content
Log in

Study of Pyrex and quartz insulators contamination effect on the X-ray intensity in a 4-kJ plasma focus device

  • Plasma Radiation
  • Published:
Plasma Physics Reports Aims and scope Submit manuscript

Abstract

The variation of the X-ray intensity has been investigated with the Pyrex and quartz insulators surface contamination in a 4-kJ plasma focus device with argon gas at 11.5-kV charging voltage. Elemental analysis (EDAX) showed that the Cu evaporated from the electrode material and was deposited on the sleeve surface improves the breakdown conditions. A small level of sleeve contamination by copper is found to be essential for good focusing action and high HXR intensity. The SEM imaging showed the grain-type structure of Cu formed on the surface and it changed the surface property. Resistance measurements of original and coated Pyrex surface proved that the copper deposition on the sleeve surface will reduce its resistance as compared to the almost infinitely large resistance of the uncontaminated sleeve. As the contamination is surpassed to some critical level, the HXR intensity from the device is deteriorated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. W. Mather, Phys. Fluids 8, 336 (1965).

    Article  ADS  Google Scholar 

  2. N. V. Filippov, T. I. Filippova, and V. P. Vinogradov, Nucl. Fusion Suppl., No. 2, 557 (1962).

    Google Scholar 

  3. H. Herold, A. Jerzykiewicz, M. Sadowski, and H. Schmidt, Nucl. Fusion 29, 1255 (1989).

    Article  Google Scholar 

  4. J. Moreno, P. Silva, and L. Soto, Plasma Sources Sci. Technol. 12, 39 (2003).

    Article  ADS  Google Scholar 

  5. A. Blagoev and V. Yordanov, Plasma Phys. Controlled Fusion 51, 1 (2009).

    Article  Google Scholar 

  6. M. Zakaullah, T. J. Baig, S. Beg, and G. Murtaza, Phys. Lett. 39, 1374 (1989).

    Google Scholar 

  7. J. N. Feugeas and G. Grigioni, J. Phys. D 30, 2026 (1997).

    Article  ADS  Google Scholar 

  8. J. Feugeas, E. Llonch, C. O. de Gonzalez, and G. Galambos, J. Appl. Phys. 64, 2646 (1988).

    Article  ADS  Google Scholar 

  9. V. Nardi, W. H. Bostick, J. Feugeas, et al., in Proceedings of the 7th IAEA Conference on Plasma Physics and Controlled Nuclear Fusion Research, Innsbruck, 1978 (IAEA, Vienna, 1979), Vol. 2, p. 143.

    Google Scholar 

  10. M. Zakaullah, A. Waheed, S. Ahmad, and S. Hussain, Plasma Sources Sci. Technol. 12, 443 (2003).

    Article  ADS  Google Scholar 

  11. M. Habibi, R. Amrollahi, and M. Attaran, J. Fusion Energy 28, 130 (2009).

    Article  ADS  Google Scholar 

  12. M. Habibi, R. Amrollahi, M. Attaran, and R. Etaati, Plasma Dev. Oper. 16, 163 (2008).

    Article  Google Scholar 

  13. R. Baghdadi, G. R. Etaati, M. Habibi, et al., J. Fusion Energy 30, 545 (2011).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Habibi.

Additional information

The article is published in the original.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Habibi, M., Sharifi, R. & Amrollahi, R. Study of Pyrex and quartz insulators contamination effect on the X-ray intensity in a 4-kJ plasma focus device. Plasma Phys. Rep. 39, 999–1003 (2013). https://doi.org/10.1134/S1063780X14020056

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1063780X14020056

Keywords