Skip to main content
Log in

A Proton Beam Delivery System Variant for the Oncological Ophthalmological Center for Proton Radiation Therapy at the NRC “Kurchatov Institute”—PNPI

  • CHARGED PARTICLE ACCELERATORS FOR NUCLEAR TECHNOLOGIES
  • Published:
Physics of Atomic Nuclei Aims and scope Submit manuscript

Abstract

A variant of the proton beam delivery system with an energy of 60 MeV for the future oncological ophthalmological center for proton radiation therapy at the isochronous cyclotron C-80 at PNPI was designed. The requirements to the beam characteristics were defined. On the basis of a series of calculations, the optimal parameters and composition of the beam line elements were determined. It is shown that such a beam line allows one to alternately and efficiently switch from the isotope production mode on the cyclotron to the mode of operation of the center for proton radiation therapy without fundamental overhaul of the accelerator systems.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.

Similar content being viewed by others

REFERENCES

  1. S. A. Artamonov, D. A. Amerkanov, E. M. Ivanov, et al., in Proceeding of the Russian Particle Accelerator Conference RUPAC2018, Protvino, Russia, p. 65.

  2. S. A. Artamonov, E. M. Ivanov, G. A. Riabov, and V. A. Tonkikh, in Proceeding of the OPENSCIENCE Conference, Gatchina, Russia, 2018, p. 1.

  3. K. G. Steffen, High Energy Beam Optics (Interscience, New York, London, Sydney, 1965).

    Google Scholar 

  4. S. A. Artamonov, A. N. Chernov, E. M. Ivanov, G. A. Riabov, and V. A. Tonkikh, in Proceeding of the Russian Particle Accelerator Conference RUPAC2016, St. Petersburg, Russia, p. 176.

  5. K. Crandall and D. Rusthoi, TRACE 3-D Documentation, 3rd ed., LA-UR-97-886 (1997).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. A. Tonkikh.

Ethics declarations

The authors declare that they have no conflicts of interest.

Additional information

Translated by K. Lazarev

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Artamonov, S.A., Ivanov, E.M., Riabov, G.A. et al. A Proton Beam Delivery System Variant for the Oncological Ophthalmological Center for Proton Radiation Therapy at the NRC “Kurchatov Institute”—PNPI. Phys. Atom. Nuclei 83, 1700–1704 (2020). https://doi.org/10.1134/S1063778820100026

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1063778820100026

Keywords:

Navigation