Abstract
A solution to the problem of wavelength calibration for Hamilton echelle spectrographs using a hollow cathode lamp operating at the Lick Observatory Shane telescope until June 9, 2011 is presented. The spectrum of the nominally thorium—argon lamp also contains, in addition to lines of thorium and argon, a number of unknown lines identified with tantalum. Atomic data for measured lines of tantalum and thorium are used to estimate the temperature of the gas in the lamp, T = 3120 ± 60 K. All all lines of TaI and TaII visible in the lamp spectrum have been selected from the VALD3 atomic line database, and a list compiled for use in the processing of spectral observations. The accuracy of this calibration approach is limited by the influence of hyperfine line splitting.
Similar content being viewed by others
References
M. Willmarth, D. W. Cheselka, M. Fitzpatrick, and M. Rippa, Thorium–Argon Spectral Atlas (2008). http://www.noao.edu/kpno/tharatlas/thar/
C. Lovis and F. Pepe, Astron. Astrophys. 468, 1115 (2007).
S. L. Redman, G. Nave, and C. J. Sansonetti, Astrophys. J. Suppl. Ser. 211, 4 (2014); arXiv:1308.5229 [astro-ph] (2013).
Y. V. Pakhomov and G. Zhao, Astron. J. 146, 97 (2013).
T. Ryabchikova, N. Piskunov, R. L. Kurucz, H. S. Stempels, U. Heiter, Y. Pakhomov, and P. Barklem, Phys. Scr. 90, 4005 (2015).
V. Tsymbal, D. Lyashko, and W. W. Weiss, in Modelling of Stellar Atmospheres, Ed. by N. Piskunov, W. W. Weiss, and D. F. Gray (Astron. Soc. Pacific, 2003), p. 49.
R. Kurucz, ATLAS9 Stellar Atmosphere Programs and 2 km/s grid, Kurucz CD-ROM No. 13 (Smithson. Astrophys. Observ., Cambridge,MA, 1993).
T. Sitnova, G. Zhao, L. Mashonkina, Y. Chen, F. Liu, Y. Pakhomov, K. Tan, M. Bolte, S. Alexeeva, F. Grupp, J.-R. Shi, and H.-W. Zhang, Astrophys. J. 808, 148 (2015).
M. S. Bessell, F. Castelli, and B. Plez, Astron. Astrophys. 333, 231 (1998).
D. Messnarz, N. Jaritz, B. Arcimowicz, V. O. Zilio, R. Engleman, Jr., J. C. Pickering, H. Jäger, G. H. Guthöhrlein, and L. Windholz, Phys. Scripta 68, 170 (2003).
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © Yu.V. Pakhomov, 2015, published in Astronomicheskii Zhurnal, 2015, Vol. 92, No. 10, pp. 834–840.
Rights and permissions
About this article
Cite this article
Pakhomov, Y.V. A list of tantalum lines for the wavelength calibration of the Hamilton echelle spectrograph. Astron. Rep. 59, 952–958 (2015). https://doi.org/10.1134/S1063772915100054
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1063772915100054