A flow injection method for the determination of cysteine (CySH) and glutathione (GSH) amino acids is reported based on lucigenin−diperiodatocuprate(III) complex chemiluminescence (CL) reaction in basic medium. Under optimum conditions, linear calibration curves were obtained in the range of 0.001–30 (R2 = 0.9998, n = 6) and 0.005–30 mg/L (R2 = 0.9989, n = 6) with detection limits (S/N = 3) of 2.5 × 10–4 and 8 × 10–4 mg/L for CySH and GSH, respectively. The relative standard deviation was 4.1% (n = 11) with injection throughput of 160 per hour. We have applied the developed method to determine CySH and GSH in pharmaceutical samples and compared the results with a spectrophotometric method. Statistical tests such as Student’s t- and F-tests were applied for both results with no significant difference observed at a 95% confidence level. The CL reaction of lucigenin−copper(III) complex is also presented.






Similar content being viewed by others
REFERENCES
Cerutti, P.A., Science, 1985, vol. 227, no. 4685, p. 375.
Cross, C.E., Halliwell, B., Borish, E.T., Pryor, W.A., Ames, B.N., Saul, R.L., McCord, J.M., and Harman, D., Ann. Int. Med., 1987, vol. 107, no. 4, p. 526.
Gazit, V., Ben-Abraham, R., Coleman, R., Weizman, A., and Katz, Y., Amino Acids, 2004, vol. 26, no. 2, p. 163.
Roederer, M., Ela, S.W., Staal, F.J.T., and Herzenberg, L.A., AIDS Res. Hum. Retroviruses, 1992, vol. 8, no. 2, p. 209.
Meister, A., Cancer Res., 1994, vol. 54, no. 7 (suppl.), p. 1969.
Zacharis, C.K., Tzanavaras, P.D., and Themelis, D.G., J. Pharm. Biomed. Anal., 2009, vol. 50, no. 3, p. 384.
Li, J.F., Huang, P.C., and Wu, F.Y., Sens. Actuators, B, 2017, vol. 240, p. 553.
Araujo, A.R.T.S., Saraiva, M.M.F.S., and Lima, J.L.F.C., Talanta, 2008, vol. 74, no. 5, p. 1511.
Zacharis, C.K. and Tzanavaras, P.D., Comb. Chem. High Throughput Screening, 2010, vol. 13, no. 6, p. 461.
Lee, S.H., Sohn, O.J., Yim, Y.S., Han, K.A., Hyung, G.W., Chough, S.H., and Rhee, J.I., Talanta, 2005, vol. 68, no. 2, p. 187.
Bulatov, A.V., Petrova, A.V., Vishnikin, A.B., and Moskvin, L.N., Microchem. J., 2013, vol. 110, p. 369.
Waseem, A., Yaqoob, M., and Nabi, A., Chem. Res. Chin. Univ., 2010, vol. 26, no. 6, p. 893.
Rezaei, B. and Mokhtari, A., Spectrochim. Acta, Part A, 2007, vol. 66, no. 2, p. 359.
Ensafi, A.A., Khayamian, T., and Hasanpour, F., J. Pharm. Biomed. Anal., 2008, vol. 48, no. 1, p. 140.
Smith, Z.M., Terry, J.M., Barnett, N.W., Gray, L.J., Wright, D.J., and Francis, P.S., Analyst, 2014, vol. 139, no. 10, p. 2416.
Dong, Y., Su, M., Chen, P., and Sun, H., Microchim. Acta, 2015, vol. 182, nos. 5–6, p. 1071.
Li, S.F., Wang, H.Y., Min, X., Zhang, L., Wang, J., Du, J., Zhang, J.Q., Wei, P., Wang, Z.Q., Zhang, H., and Wu, X.W., J. Biomed. Sci. Eng., 2014, vol. 7, no. 6, p. 307.
Waseem, A., Yaqoob, M., and Nabi, A., Luminescence, 2008, vol. 23, no. 3, p. 144.
Dong, Y.P., Shi, M.J., Tong, B.H., and Zhang, Q.F., Luminescence, 2012, vol. 27, no. 5, p. 414.
Lok, K.S., Kwok, Y.C., and Nguyen, N.T., Sens. Actuators, B, 2012, vol. 169, p. 144.
Pan, J., Zhang, Y., Xu, J., Liu, J., Zeng, L., and Bao, G.M., RSC Adv., 2015, vol. 5, no. 118, p. 97781.
Kuśmierek, K., Chwatko, G., Glowacki, R., and Bald, E., J. Chromatogr. B: Anal. Technol. Biomed. Life Sci., 2009, vol. 877, no. 28, p. 3300.
Kominkova, M., Horky, P., Cernei, N., Tmejova, K., Nedecky, B.R., Guran, R., Pohanka, M., Zitka, O., Adam, V., and Kizek, R., Int. J. Electrochem. Sci., 2015, vol. 10, p. 1716.
Kataoka, H., Takagi, K., and Makita, M., Biomed. Chromatogr., 1995, vol. 9, no. 2, p. 85.
Ojani, R., Raoof, J.B., and Zarei, E., J. Electroanal. Chem., 2010, vol. 638, no. 2, p. 241.
Hodáková, J., Preisler, J., Foret, F., and Kubáň, P., J. Chromatogr. A, 2015, vol. 1391, p. 102.
Cuicui, W., Wensheng, C., and Xueguang, S., Chem. Res. Chin. Univ., 2016, no. 6, p. 912.
Ruiz-Díaz, J.J., Torriero, A.A.J., Salines, E., Marchevsky, E.J., Sanz, M.I., and Raba, J., Talanta, 2006, vol. 68, p. 1343.
Maya, F., Estela, J.M., and Cerdà, V., Talanta, 2010, vol. 81, p. 1.
Ruzicka, J. and Hansen, E.H., Flow Injection Analysis, New York: Wiley, 1988, 2nd ed.
García-Campaña, A.M. and Baeyens, W.R.G., Chemiluminescence in Analytical Chemistry, New York: Marcel Dekker, 2001.
Marquette, C.A. and Blum, L.J., Anal. Bioanal. Chem., 2006, vol. 385, no. 3, p. 546.
Timofeeva, I.I., Vakh, C.S., Bulatov, A.V., and Worsfold, P.J., Talanta, 2018, vol. 179, p. 246.
Gorman, B.A., Francis, P.S., and Barnett, N.W., Analyst, 2006, vol. 131, no. 5, p. 616.
Adcock, J.L., Barnett, N.W., Barrow, C.J., and Francis, P.S., Anal. Chim. Acta, 2014, vol. 807, p. 9.
Su, M., Chen, P., and Sun, H., TrAC, Trends Anal. Chem., 2018, vol. 100, p. 36.
Mervartová, K., Polášek, M., and Calatayuad, M., J. Pharm. Biomed. Anal., 2007, vol. 45, p. 367.
Advances in Flow Injection Analysis and Related Technique, vol. 54, Kolev, S.D. and McKelvie, I.D., Eds., Amsterdam: Elsevier, 2008.
Chi, Q., Chen, W., and He, Z., Luminescence, 2015, vol. 30, no. 7, p. 990.
Hinze, W.L., Riechi, T.E., Singh, H.N., and Baba, Y., Anal. Chem., 1984, vol. 56, no. 12, p. 2180.
Yaqoob, M., Asghar, M., and Nabi, A., Luminescence, 2015, vol. 30, no. 7, p. 950.
Jose, T.P. and Tuwar, S.M., J. Mol. Struct., 2007, vol. 827, p. 137.
Asghar, M., Yaqoob, M., and Nabi, A., Chem. Res. Chin. Univ., 2017, vol. 33, no. 3, p. 354.
Speisky, H., Gómez, M., Carrasco-Pozo, C., Pastene, E., Lopez-Alarcón, C., and Olea-Azar, C., Bioorg. Med. Chem., 2008, vol. 16, no. 13, p. 6568.
Tamidate, T., Kaneyasu, T., Segawa, T., and Watanabe, H., Bull. Chem. Soc. Jpn., 1991, vol. 64, no. 6, p. 1991.
Montano, L.A. and Ingle, S.J., Jr., Anal. Chem., 1979, vol. 51, no. 7, p. 919.
Veazeg, R.L. and Nieman, T.A., Anal. Chem., 1979, vol. 51, no. 13, p. 2092.
Sohrin, Y., Iwamoto, S., Akiyama, S., Fujita, T., Kugii, T., Obata, H., Nakayama, E., Goda, S., Fujishima, Y., Hasegawa, H., Ueda, K., and Matsui, M., Anal. Chim. Acta, 1998, vol. 363, no. 1, p. 11.
Ussher, S.J., Milne, A., Landing, W.M., Attiq-ur-Rehman, K., Seguret, M.J.M., Holland, T., Achterberg, E.P., Nabi, A., and Worsfold, P.J., Anal. Chim. Acta, 2009, vol. 652, nos. 1−2, p. 259.
Besada, A., Tadros, N.B., and Gawargious, Y.A., Microchim. Acta, 1989, vol. 99, nos. 1–2, p. 143.
Miller, J.N. and Miller, J.C., Statistics and Chemometrics for Analytical Chemistry, Essex, UK: Pearson, 2005, 5th ed.
ACKNOWLEDGMENTS
The authors also acknowledge the Department of Chemistry, University of Balochistan, Quetta, Pakistan for providing laboratory facilities.
Funding
One of the authors acknowledges the Higher Education commission, Islamabad for providing laptop and financial support under Prime Minister of Pakistan Laptop and Fee Reimbursement Scheme.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Ahmed, Z., Yaqoob, M., Asghar, M. et al. Flow-Injection Lucigenin–Cu(III) Complex Chemiluminescence Determination of Cysteine and Glutathione in Pharmaceutical Formulations. J Anal Chem 76, 466–475 (2021). https://doi.org/10.1134/S1061934821040134
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934821040134