Abstract
In this study, we reported an effective electrochemical sensor for determination of antidepressant drug fluvoxamine using carbon paste electrode modified by nickel nanoparticles deposited on the surface of electrode by electrodeposition from micellar solution. The effective parameters at response of electrode to the drug, such as surfactant concentration, applied potential and duration of potential applying for deposition of nickel on the surface of carbon paste electrode were optimized. The modified electrode was characterized by scanning electron microscopy and energy-dispersive X-ray spectroscopy methods. Electrocatalytic oxidation of fluvoxamine at the surface of modified electrode was studied using cyclic voltammetry, chronoamperometry and chronocoulometry methods. The peak currents and concentrations of fluvoxamine show a good linear response in the range form 1.2 × 10–6–2 × 10–4 M (R2 = 0.9988). The method was successfully applied for determination of fluvoxamine in pharmaceutical sample and human blood plasma.
Similar content being viewed by others
REFERENCES
Benfield, P., Drugs, 1986, vol. 32, p. 313.
Tatar Ulu, S., Chromatographia, 2006, vol. 64, nos. 3–4, p. 169.
Pullen, R.H. and Fatmi, A.A., J. Chromatogr. A, 1992, vol. 574, p. 101.
Ohkubo, T., Shimoyama, R., Otani, K., Yoshida, K., Higuchi, H., and Shimizu, T., Anal. Sci., 2003, vol. 19, p. 859.
Tatar Ulu, S., J. Pharm. Biomed. Anal., 2007, vol. 43, p. 1444.
Foda, N.H., J. Liq. Chromatogr. Relat. Technol., 1995, vol. 18, p. 1591.
Schweitzer, C., Spahn, H., and Mutschler, E., J. Chromatogr. A, 1986, vol. 382, p. 405.
Annapurna, V., Jyothi, G., Rohini Kumari, T., and Sailaja, B.B.V., E-J. Chem., 2010, vol. 7, p. 624.
Starczewska, B., J. Trace Microprobe Tech., 2001, vol. 19, p. 19.
Sanghavi, B.J., Wolfbeis, O.S., Hirsch, T., and Swami, N.S., Microchim. Acta, 2015, vol. 182, p. 1.
Karuppiah, C., Cheemalapati, S., Chen, S.M., and Palanisamy, S., Ionics, 2015, vol. 21, p. 231.
Cheemalapati, S. and Palanisamy, S., J. Appl. Electrochem., 2014, vol. 44, p. 317.
Medyantseva, E.P., Varlamova, R.M., Gimaletdinova, D.A., Fattakhova, A.N., and Budnikov, G.K., J. Anal. Chem., 2008, vol. 63, p. 275.
Medyantseva, E.P., Brusnitsyn, D.V., Varlamova, R.M., Maksimov, A.A., Fattakhova, A.N., Konovalova, O.A., and Budnikov, G.K., Russ. J. Appl. Chem., 2015, vol. 88 p, p. 40.
Nevado, J.J.B., Rodriguez Flores, J., and Castañeda Peñalvo, G., Electroanalysis, 2000, vol. 12, p. 1059.
Nouws, H.A., Delerue-Matos, C., Barros, C., Rodrigues, C., and Santos-Silva, C., Anal. Bioanal. Chem., 2005, vol. 382, p. 1662.
Madrakian, T., Soleimani, T., and Afkhami, A., Sens. Actuators, B, 2015, vol. 210, p. 259.
Sasikala, G., Dhanasekaran, R., and Subramanian, C., Thin Solid Films, 1997, vol. 302, p. 71.
Bauer, A., Gyenge, E.L., and Oloman, C.W., Electrochim. Acta, 2006, vol. 51, p. 5356.
El-Deab, M.S., Electrochim. Acta, 2009, vol. 54, p. 3720.
Gu, C., Lian, J., Jiang, Z., and Jiang, Q., Scr. Mater., 2006, vol. 54, p. 579.
Sheridan, E., Hjem, J., and Forster, R.J., J. Electroanal. Chem., 2007, vol. 608, p. 1.
Inamdar, A.I., Mujawar, S.H., Ganesan, V., and Patil, P.S., Nanotechnology, 2008, vol. 19, p. 32.
Siddig, M.A., Radiman, S., Jan, L.S., and Muniandy, S.V., Colloids Surf., A, 2006, vol. 276, p. 15.
Pham, T.M., Maitz, M.F., Richter, E., Reuther, H., Prokert, F., and Mucklich, A., J. Electroanal. Chem., 2004, vol. 572, p. 185.
Mirceski, V. and Gulaboski, R., Electroanalysis, 2001, vol. 13, p. 1326.
Mirceski, V. and Gulaboski, R., J. Solid State Electrochem., 2003, vol. 7, p. 157.
Muhammad Khan , A., and Sakhavat Shah, S., J. Chem. Soc. Pakistan, 2008, vol. 30, p. 186.
Bard, A.J. and Faulkner, L.R., Electrochemical Methods: Fundamentals and Applications, New York: Wiley, 2001, 2nd ed.
Kishore, M., Surendrababu, K., Hanumantharao, Y., Naga Hima Bindu, G., and Janardhan, M., Int. J. Appl. Biol. Pharm. Technol., 2010, vol. 1, p. 561.
Funding
Because the work was completly done in university and company only prepared us free drug samples therefore it is not funding. We would like to thank the Islamic Azad University, Ayatollah Amoli Branch and Sobhan pharmaceutical company for supporting the research project.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The authors declare no conflict of interest.
Rights and permissions
About this article
Cite this article
Ali Ahmadi Diva, Fathi, S. & Chekin, F. Determination of Fluvoxamine in Real Samples using Carbon Paste Electrode Modified by Electrodeposition of Nickel. J Anal Chem 74, 809–815 (2019). https://doi.org/10.1134/S1061934819080021
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934819080021