Abstract
Deposited cobalt microparticales (Co-MPs) film onto the platinum disk electrode has been successfully used as a new amperometric sensor for the determination of ascorbic acid (AA). AA is detected by surface catalyzed oxidation involving cobalt(III) oxyhydroxides in alkaline solution. The Co-MPs/Pt electrode exhibits a high electrocatalytic activity toward the AA oxidation. The diffusion coefficient of AA (6.09 × 105 cm2/s) and the catalytic rate constant (k cat = 6.27 × 103 M–1s–1) have been determined using electrochemical approaches. The amperometric response of the modified electrode is linear against the AA concentration in the range (0.01‒0.48 mM). The sensor displays the best activity with a high response signal, a good sensitivity of 74.3 μA/mM, a low detection limit of 2.5 μM (signal/noise = 3) and a fast response time (<3 s). Moreover, the reproducibility, selectivity and applicability of this biosensor are satisfactorily evaluated.
Similar content being viewed by others
References
Agui, L., Pena-Fartal, C., Yanez-Sedeno, P., and Pingararrom, J.M., Talanta, 2007, vol. 74, p. 412.
Dilgin, Y. and Nisli, G., Chem. Pharm. Bull., 2005, vol. 53, p. 1251.
Farmatsevticheskii analiz lekarstvennykh sredstv (Pharmaceutical Analysis of Pharmaceuticals), Shapovalova, V.A., Ed., Kharkov: Rubikon, 1995.
Perez-Ruiz, T., Martinez-Lozano, C., Sanz, A., and Guillen, A., J. Pharm. Biomed. Anal., 2004, vol. 34, p. 551.
Lechien, F., Valenta, P., Nurnberg, H.W., and Patriarche, G.J., Fresenius’ Z. Anal. Chem., 1982, vol. 105, no. 2, p. 311.
Kachoosangi, R.T., Banks, C.E., and Compton, R.G., Electroanalysis, 2006, vol. 18, p. 741.
Lin, X. and Li, Y., Electrochim. Acta, 2006, vol. 21, p. 5794.
Chauhan, N., Narang, J., Rawal, R., and Pundir, C.S., Synth. Met., 2011, vol. 161, p. 2427.
Kul, D., Ghica, M.E., Pauliukaite, R., and Brett, C.M.A., Talanta, 2013, vol. 111, p. 76.
Pisoschi, A.M., Pop, A., Serban, A.I., and Fafaneata, C., Electrochim. Acta, 2014, vol. 121, p. 443.
Pournaghi-Azar, M.H. and Ojani, R., J. Solid State Electrochem., 1999, vol. 3, p. 392.
Shaidarova, L.G., Gedmina, A.V., and Budnikov, G.K., Russ. J. Appl. Chem., 2003, vol. 76, no. 5, p. 755.
Shaidarova, L.G., Gedmina, A.V., Chelnokova, I.A., and Budnikov, G.K., J. Anal. Chem., 2006, vol. 61, no. 6, p. 601.
Kalcher, K., Electroanalysis, 1990, vol. 2, p. 419.
Shaidarova, L.G., Gedmina, A.V., Zhaldak, E.R., Chelnokova, I.A., and Budnikov, G.K., J. Anal. Chem., 2014, vol. 69, no. 8, p. 741.
Wei, M.Y., Huang. R., and Guo, L.H., J. Electroanal. Chem., 2012, vol. 664, p. 156.
Rohani, T. and Taher, M.A., Talanta, 2009, vol. 78, p. 743.
Zhang, X., Yu, S., He, W., Uyama, H., Xie, Q., Zhang, Lu., and Yang, F., Biosens. Bioelectron., 2014, vol. 55, p. 446.
Kaura, B., Pandiyanb, T., Satpatic, B., and Srivastava, R., Colloids Surf., B, 2013, vol. 111, p. 97.
Tian, L., Bian, J., Wang, B., and Qi, Y., Electrochim. Acta, 2010, vol. 55, p. 3083.
Fan, L.F., Wu, X.Q., Guo, M.D., and Gao, Y.T., Electrochim. Acta, 2007, vol. 52, p. 3654.
Song, Y., He, Z., Zhu, H., Hou, H., and Wang, L., Electrochim. Acta, 2011, vol. 58, p. 757.
Spataru, T., Osiceanu, P., Munteanu, C., Spataru, N., and Fujishima, A., J. Solid State Electrochem., 2012, vol. 16, p. 3897.
Ojani, R., Raoof, J.-B., and Norouzi, B., J. Solid State Electrochem., 2011, vol. 15, p. 1139.
Yang, F., Wang, J., Cao, Y., Zhang, Lu., and Zhang, X., Sens. Actuators, B, 2014, vol. 205, p. 20.
Shaidarova, L.G., Ziganshina, S.A., Medyantseva, E.P., and Budnikov, G.K., Russ. J. Appl. Chem., 2004, vol. 77, no. 2, p. 241.
Shaidarova, L.G., Gedmina, A.V., and Budnikov, G.K., J. Anal. Chem., 2003, vol. 58, no. 2, p. 171.
Laviron, E., J. Electroanal. Chem., 1979, vol. 101, no. 1, p. 19.
Budnikov, G.K., Printsipy i primenenie vol’tampernoi ostsillograficheskoi polyarografii (Principles and Use of Voltammetric Oscillographic Polarography), Kazan: Kazansk. Gos. Univ., 1975.
Bard, A.J. and Faulkner, L.R., Electrochemical Methods: Fundamentals and Applications, New York: Wiley, 2000.
Kutner, W., Wang, J., L’her, M., and Buck, R.P., Pure Appl. Chem., 1998, vol. 70, p. 1301.
Alireza, M. and Mohammad, A.T., Sens. Actuators, B, 2007, vol. 123, p. 733.
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
Rights and permissions
About this article
Cite this article
Doulache, M., Saidat, B. & Trari, M. Electrocatalytic performance of cobalt microparticles film-modified platinum disk electrode for amperometric detection of ascorbic acid. J Anal Chem 72, 333–341 (2017). https://doi.org/10.1134/S106193481703008X
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S106193481703008X