Abstract
We conducted a clinical trial to analyze human serum containing carbamazepine by using the differential pulse voltammetry (DPV) method with a glassy carbon electrode, and compared it with the fluorescence polarization immunoassay (FPIA). Thirty patients, who visited our hospital to have their serum carbamazepine level checked, were enrolled. Ten mL of venous blood was collected from each patient and analyzed by DPV and FPIA methods. The correlation between the carbamazepine concentrations determined by DPV and FPIA was good, with an RSQ of 0.998. The similarity of the results indicates that these two methods can be used interchangeably. The DPV method using a glassy carbon electrode may be a potential alternative method to determine the carbamazepine level in human serum.
This is a preview of subscription content,
to check access.Similar content being viewed by others
References
Terao, T., Biol. Psychiatry, 1999, vol. 45, p. 381.
Meador, K.J., Gevins, A., and Loring, D.W., Neurology, 2007, vol. 69. p. 2076.
McNamara, J.O., Molinoff, P.B., and Ruddon, R.N., (Eds). Mc Graw Hill, 9th ed., 1996, p. 461.
Hollis, J., Forrester, L., Brodaty, H., et al., Aust. N. Z. J. Psychiatry, 2007, vol. 41, p. 751.
Lin, J. and Ju, H., Biosens. Bioelectron., 2005, vol. 20, no. 8, p. 1461.
Uslu, B. and Özkan,, S.A., Electrochim. Acta, 22004, vol. 49, p. 432.
Uslu, B., Dogan, B., and Özkan,, S.A., Anal. Chim. Acta, 2005, vol. 537, no. 2, p. 307.
Messiha, F.S., Alcohol (Fayetteville, N.Y.)., 1986, vol. 3, no. 2, p. 135.
Moses, G.S., Rao, K.M., Srinivasa, R.N., and Ramachandraiah, A., J. Ind. Chem. Soc., 1995, vol. 72, no. 5, p. 333.
García-García, M.A., Domínguez-Renedo, O., Alonso-Lomillo, A., and Arcos-Martínez, M.J., Sensor Lett., 2009, vol. 7, p. 586.
Atkins, S., Sevilla, J.M., Blazquez, M., Pineda, T., and Gonzalez Rodriguez, J., Electroanal., 2010, vol. 22, p. 2961.
Shankara, S.K. and Seetharamappa, J., Anal. Lett., 2010, vol. 43, p. 618.
Zang, Z.Q., Chen, S.Z., Huang, W.L., and Xu, F., Acta Pharm. Sini., 1993, vol. 28, p. 312.
Moses, G.S., Rao, K.M., Srinivasa Rao, N., and Ramachandraiah, A., J. Indian Chem. Soc., 1995, vol. 72, p. 333.
Wang, H.Y., Pan, M.L., Su, Y.O., and Lin, W.Y., J. Anal. Chem., 2011, vol. 66, p. 415.
Bland, J.M. and Altman, D.G., Lancet, 1986, vol. 1, p. 307.
Kozer, E., Verjee, Z., and Koren, G., N. Engl. J. Med., 2000, vol. 343, no. 26, p. 1971.
Chattergoon, D.S., Verjee, Z., Anderson, M., Johnson, D., McGuigan, M.A., Koren, G., and Ito, S., J. Toxicol. Clin. Toxicol., 1998, vol. 36, no. (1–2), p. 109.
Colbert, D.L., Drug abuse screening with immunoassays: unexpected cross-reactivities and other pitfalls., Br. J. Biomed. Sci., 1994, vol. 51, p. 136.
Inam, R. and Somer, G., Food Chem., 1999, vol. 66, no. 3, p. 381.
Turner, A.P., Acta Anaesthesiol. Scand. Suppl., 1995, vol. 104, p. 15.
Inam, R. and Somer, G., Talanta, 1998, vol. 46, no. 6, p. 1347.
Abo-el-Wu, K.B., Fei, J.J., and Hu, S.S., Anal. Biochem, 2003, vol. 18, p. 100.
Wang, Z.H., Luo, G.A., Xiao, F.S., and Wang, G.Y., Chem. J. Chin. Univ., 2003, vol. 5, p. 811.
Qi, H. and Zhang, C., Electroanal., 2005, vol. 17, p. 832.
Ding, Y.P., Liu, W.L., Wu, Q.S., and Wang, X.G., J. Electroanal. Chem., 2005, vol. 575, p. 275.
Maali, N., Bioelectrochem., 2004, vol. 64, no. 1, p. 99.
Ghanem, M.A., Electrochem. Commun., 2007, vol. 9, no. 10, p. 2501.
Author information
Authors and Affiliations
Additional information
The article is published in the original.
Rights and permissions
About this article
Cite this article
Pan, M.L., Lin, W.Y., Wang, H.Y. et al. Determination of carbamazepine: a comparison of the differential pulse voltammetry (DPV) method and the immunoassay method in a clinical trial. J Anal Chem 69, 57–61 (2014). https://doi.org/10.1134/S1061934814010110
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934814010110