Abstract
Linear ion traps exhibit greater space charge capacity compared to conventional 3D Paul traps. Commercial ion traps are made of electrodes of hyperbolic shape. The present work investigates the possibilities of designing linear ion traps from simple electrodes, which are relatively cheap and handy for manufacturing and, at the same time, are comparable to commercial ion traps in resolving power of mass analysis. Using computer simulations and optimization of resonance ejection scan, it is shown linear ion traps can be made of electrodes of triangular cross-section with an ejection slit width of 16% of the trap inradius; the resolving power of the mass spectrum is more than 18000.
Similar content being viewed by others
References
http://www.thermoscientific.com/ecomm/servlet/productsdetail_11152_L10878_87168_11960637-1. Cited October 18, 2011.
Cox, K.A., Cleven, C.D., and Cooks, R.G., Int. J. Mass Spectrom., 1995, vol. 144, no. 2, p. 47.
Bier, M., Park, M., and Syka, J., US Patent 5420425, 1995.
Schwartz, J., Senko, M., and Syka, J., J. Amer. Soc. Mass Spectrom., 2002, vol. 13, no. 4, p. 659.
Ouyang, Z. and Cooks, R.G., US Patent 6838666, 2005.
Ding, C., Patent Application WO 2005/119737 A1, 2004.
Mu, H., Jiang, G.Y., Yang, X., Lin, T., Zhang, J., and Ding, L., A Digital Linear Ion Trap Based on Ceramic Printed Circuit Boards, Proc. 58th ASMS Conf. on Mass Spectrometry and Allied Topics, Salt Lake City, 2010, p. 804.
Doroshenko, V.M. and Cotter, R.J., Rapid Commun. Mass Spectrom., 1996, vol. 10, no. 8, p. 65.
Syka, J.E.P., Commercialisation of the Quadrupole Ion Trap, in Practical Aspects of Ion Trap Mass Spectrometry, March, R.E. and Todd, J.F.J., Eds., FL: CRC Press, 1995, vol. 1, p. 169.
Louris, J., Schwartz, J., Stafford, G., Suka, J., and Taylor, D., The Paul Ion Trap Mass Selective Instability Scan: Trap Geometry and Resolution, Proc. 40th ASMS Conf. on Mass Spectrometry and Allied Topics, Washington, 1992.
Franzen, J., Gabling, R.-Y., Shubert, M., and Wang, Y., Non-Linear Ion Traps, in Practical Aspects of Ion Trap Mass Spectrometry, vol. 1, March, R.E. and Todd, J.F.J., Eds., FL: CRC Press, 1995, p. 49.
Makarov, A.A., Anal. Chem., 1996, vol. 68, no. 22, p. 4257.
Plass, W.R., Li, H., and Cooks, R.G., Int. J. Mass Spectrom., 2003, vol. 228, no. 12, p. 237.
Ding Li, Sudakov, M., and Kumashiro, S., Int. J. Mass Spectrom., 2002, vol. 13, no. 2, p. 1.
Sudakov, M., AXSIM—New Software for Simulation of Modern Mass Spectrometry Devices, Proc. 7th Int. Conf. Charged Particle Optics, Cambridge, 2006, p. 717.
Parks, J.H. and Szoke, A., J. Chem. Phys., 1995, vol. 103, no. 4, p. 1422.
Papanastasiou, D., Belgacem, O., Sudakov, M., and Raptakis, E., A Quadrupole Ion Trap/Time-of-Flight Mass Spectrometry Combined with a Vacuum Matrix-Assisted Laser Desorption Ionization Souce, in: Practical Aspects Trapped Ion Mass Spectrometry, March, R.E. and Todd, J.F.J., Eds., FL: CRC Press, 2010, vol. 4, p. 804.
Londry, F.A., Wells, G.J., and March, R.E., Rapid Commun. Mass Spectrom., 1993, vol. 7, no. 7, p. 43.
Sudakov, M., Patent Application WO 2011/099889 A1, 2010.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © M.Yu. Sudakov, M.V. Apatskaya, V.V. Vitukhin, A.A. Trubitsyn, 2012, published in Mass-Spektrometria, 2012, Vol. 9, No. 1, pp. 43–52.
The article was translated by the authors.
Rights and permissions
About this article
Cite this article
Sudakov, M.Y., Apatskaya, M.V., Vitukhin, V.V. et al. A new linear ion trap with simple electrodes. J Anal Chem 67, 1057–1065 (2012). https://doi.org/10.1134/S1061934812140092
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934812140092