Skip to main content
Log in

Use of time-of-flight mass spectrometry for monitoring helium microcontamination in the industrial manufacture of extra high purity inert gases

  • Articles
  • Published:
Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

A time-of-flight EMG-20-9 mass spectrometer was designed for the online monitoring of helium impurity at the 0.05 ppm level. The spectrometer was introduced for the continuous control of the gas mixture composition in the technology of neon purification from the helium impurity in spite of the large difference in the concentrations of components. The instrument was certified as a measuring facility and introduced into the State Register of Measurement Instrumentation of the Russian Federation. The characteristics of the mass spectrometer and its modifications were overviewed and its possibilities for monitoring xenon and krypton production from air were shown.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bondarenko, V.L., Chekh, Yu.A., and Rura, V.N., Tekhnich. Gazy, 2005, no. 1, p. 46.

  2. Cook, K.D., Bennett, K.H., and Haddix, M.L., Ind. Eng. Chem. Res., 1999, vol. 38, p. 1192.

    Article  CAS  Google Scholar 

  3. Hoffmann, T., Real-Time Mass Spectrometry, Anal. Bioanal. Chem., 2003, vol. 375, p. 36.

    CAS  Google Scholar 

  4. Reinhardt, B., Cordonnier, A., and Florent, P., Powder Technol., 1999, vol. 101, no. 1, p. 81.

    Article  CAS  Google Scholar 

  5. Kozlovskii, A.V., RF Patent 2103763, 1998, http://www.fips.ru/wps/wcm/connect/connect-ru/ru/informresources/inform-retrieval-system/.

  6. Mamyrin, B.A., Karataev, V.I., Shmikk, D.V., and Zagulin, V.A., Zhurn. Eksp. Teor. Fiz., 1973, vol. 64, no. 1, p. 82.

    CAS  Google Scholar 

  7. Zorin, A.A., Kozlovskii, A.V., Markovskii, S.N., Mozhaev, A.N., and Pilyugin, I.I., Vakuumn. Tekhn. Tekhnol., 2006, vol. 16, no. 1, p. 35.

    Google Scholar 

  8. Markovskii, S.N., Kozlovskii, A.V., Fedichkin, I.L., Gurevich, E.L., Begak, O.Yu., and Borodin, A.V., Zavod. Lab. Diagn. Mater., 2000, no. 6, p. 8.

  9. Mamyrin, B.A., Prib. Tekh. Eksp., 1990, vol. 33, no. 1, p. 205.

    Google Scholar 

  10. Aruev, N.N., Zhdan, V.T., Kozlovskii, A.V., Markovskii, S.N., and Pilyugin, I.I., Mass-spektrometria, 2008, vol. 5, no. 4, p. 289.

    CAS  Google Scholar 

  11. Kozlovskii, A.V., Markovskii, S.N., Mozhaev, A.N., Pilyugin, I.I., Bondarenko, V.L., Rura, V.N., and Chekh, Yu.A., Tekhnich. Gazy, 2007, no. 1, p. 67.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. T. Zhdan.

Additional information

Original Russian Text © V.T. Zhdan, A.V. Kozlovskii, A.N. Mozhaev, I.I. Pilyugin, 2010, published in Zhurnal Mass-spektrometria,7(1), pp. 60–64.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhdan, V.T., Kozlovskii, A.V., Mozhaev, A.N. et al. Use of time-of-flight mass spectrometry for monitoring helium microcontamination in the industrial manufacture of extra high purity inert gases. J Anal Chem 65, 1532–1536 (2010). https://doi.org/10.1134/S1061934810140145

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1061934810140145

Keywords

Navigation