Abstract
Previously studied reactions of the formation of ion associates between polyallyldimethylammonium chloride (PADAC) and triphenylmethane dyes were used in the determination of the residual concentration of polymeric flocculants. Rapid procedures were developed for analyzing hydrochemical objects of different types without the separation of PADAC and the effect of interferents was taken into account. The analysis of process solutions of water treatment was performed using the reaction with Xylenol Orange; the analysis of potable water and purified sewage waters was based on the reaction with Erythrosine. The precision of the procedures is at a level of RSD ≤ 20%. The systematic error does not exceed the tolerable level if the concentrations of metals and surfactants in the studied water are lower than their maximum permissible concentrations.
Similar content being viewed by others
References
Antonova, T.V., Vershinin, V.I., and Dedkov, Yu.M., Zavod. Lab. Diagn. Mater., 2004, vol. 70, no. 1, p. 3.
Antonova, T.V., Vershinin, V.I., and Dedkov, Yu.M., Zh. Anal. Khim., 2005, vol. 60, no. 3, p. 278 [J. Anal. Chem. (Engl. Transl.), vol. 60, no. 3, p. 247].
Antonova, T.V., Vershinin, V.I., and Dedkov, Yu.M., Zh. Anal. Khim., 2006, vol. 61, no. 5, p. 506 [J. Anal. Chem. (Engl. Transl.), vol. 61, no. 5, p. 465].
Perechen’ rybokhozyaistvennykh normativov, predel’no dopustimykh kontsentratsii i orientirovochno bezopasnykh urovnei vozdeistviya vrednykh veshchestv dlya vody vodnykh ob”ektov, imeyushchikh rybokhozyaistvennoe znachenie (A List of Fisheries Standards for Maximum Permissible Concentrations and Safe Levels of Harmful Substances in Water of Fishery Water Bodies), Moscow: VNIRO, 1999.
Veitser, Yu.I. and Mints, D.M., Vysokomolekulyarnye flokulyanty v protsessakh ochistki prirodnykh i stochnykh vod (High Molecular Flocculants in Water Treatment), Moscow: Stroiizdat, 1984.
GOST (State Standard) R 51593-2000: Potable Water: Sampling, Moscow: Izd. Standartov, 2000.
MU (Practical Guidelines) 2.1.4.1060-01: Sanitation and Epidemiological Control in the Use of Synthetic Polyelectrolytes in Portable Water Supply, Moscow: RF Ministry of Public Health, 2001.
Certificate no. 10-414 on Metrological Accreditation of the Procedure for Determining Cationic Polyelectrolyte VPK-402 by Colorimetry, Rostov-on-Don, 1993.
GOST (State Standard) 27384-2002: Water: Rates of Measurement Error Characteristics of Composition and Properties, Minsk: Izd. Standartov, 2002.
Author information
Authors and Affiliations
Additional information
Original Russian Text © T.V. Antonova, V.I. Vershinin, 2008, published in Zhurnal Analiticheskoi Khimii, 2008, Vol. 63, No. 3, pp. 247–252.
Rights and permissions
About this article
Cite this article
Antonova, T.V., Vershinin, V.I. Spectrophotometric determination of polymeric flocculants in waters of different types. J Anal Chem 63, 223–227 (2008). https://doi.org/10.1134/S1061934808030052
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1061934808030052