Skip to main content
Log in

Accelerating Algorithm for Total Focusing Method Imaging Based on Optimization of Full Matrix Data

  • ACOUSTIC METHODS
  • Published:
Russian Journal of Nondestructive Testing Aims and scope Submit manuscript

Abstract

Total focusing method (TFM) for ultrasonic phased array imaging has the advantages of high imaging resolution, full-scale dynamic focusing and low undetected error rate in ultrasonic detection. However, the problem of long imaging time usually limits its practically applications. The imaging speed can be raised sharply by directly upgrading the detection hardware, but this solution is unavoidable to increase the detection cost. This study is interested in how to improve the TFM imaging speed based on the existing hardware. Thus, an accelerating algorithm combining the asymmetrical optimization mechanism for the full matrix data of ultrasonic array with the sparse one was proposed to simplify the imaging process aiming at reducing the imaging time. Furthermore, TFM imaging experiments of the transverse through hole flaw were finally carried out to evaluate the performance of the proposed algorithm. The results show that in sparse optimization algorithms, the imaging speed of 2 elements sparse is faster and the signal-to-noise ratio of image is higher. The asymmetric optimization and 2 elements sparse optimization are combined in proposed algorithm. The imaging speed of proposed algorithm is improved by 34.56%. Similarly, it is 10.50 and 24.94%, respectively faster than using the asymmetric and 2 elements sparse optimization algorithm. Meanwhile, it is also founded that the signal-to-noise ratio (SNR) of TFM imaging after amplitude optimization is greatly increased by 55.99% without losing the information on the defect characterization. The proposed accelerating algorithm provides an important reference for the practical application of TFM in the ultrasonic phased array flaw detection system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.
Fig. 8.
Fig. 9.
Fig. 10.

Similar content being viewed by others

REFERENCES

  1. Holmes, C., Drinkwater, B. W., and Wilcox P. D., Post processing of the full matrix of ultrasonic transmit-receive array data for nondestructive evaluation, NDT & E Int., 2005, vol. 38, pp. 701–711. https://doi.org/10.1134/S1061830920110029

    Article  CAS  Google Scholar 

  2. Holmes, C., Drinkwater, B.W., and Wilcox P.D., Advanced post-processing for scanned ultrasonic arrays: Application to defect detection and classification in nondestructive evaluation, Ultrasonics, 2008, vol. 48, pp. 636–642.

    Article  Google Scholar 

  3. Holmes, C., Drinkwater, B.W., and Wilcox, P.D., The post-processing of ultrasonic array data using the total focusing method, Insight: Nondestr. Test. Condit. Monit., 2004, vol. 46, pp. 677–680.

    Article  Google Scholar 

  4. June, L., Imagerie ultrasonore par emission d’ondes planes pour le contrôle de structuzres complexes en immersion, Pour l’obtention du grade de Docteur de l’université Paris–Diderot, Paris, 2016.

  5. Couture, O., Fink, M., and Tanter, M., Ultrasound contrast plane wave imaging, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 2012, vol. 59, pp. 2676–2683. https://doi.org/10.1109/Tuffc.2012.2508

    Article  Google Scholar 

  6. Montaldo, G., et al., Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 2009, vol. 56, pp. 489–506. https://doi.org/10.1109/Tuffc.2009.1067

    Article  Google Scholar 

  7. Avagyan, V.K., and Bazulin, E.G., Increasing the rate of recording echo signals with an ultrasonic antenna array using code division multiple access technology, Russ. J. Nondestr. Test., 2020, vol. 56, pp. 873–886. https://doi.org/10.1134/S1061830920110029

    Article  Google Scholar 

  8. Bazulin, E., The maximum entropy method in ultrasonic non-destructive testing – increasing the resolution, image noise reduction and echo acquisition rate, Entropy, 2018, vol. 20, p. 621.

    Article  Google Scholar 

  9. Sutcliffe, M., Weston, M., Dutton, B., et al., Real-time full matrix capture for ultrasonic non-destructive testing with acceleration of post-processing through graphic hardware, NDT & E Int., 2012, vol. 51, pp. 16–23.

    Article  Google Scholar 

  10. Njiki, M., Elouardi, A., Bouaziz, S., et al., A real-time implementation of the total focusing method for rapid and precise diagnostic in nondestructive evaluation, IEEE 24th Int. Conf. Appl. Specific Syst. Archit. Proces., Washington D.C., 2013.

  11. Lambert, J., Pedron, A., and Gens, G., Analysis of multicore CPU and GPU toward parallelization of total focusing method ultrasound reconstruction, Conf. Des. Archit. Sign. Imag. Proces., 2012.

    Google Scholar 

  12. Carcreff, E. and Braconnier, D., Comparison of conventional technique and migration approach for total focusing, Phys. Procedia, 2015, vol. 70, pp. 566–569.

    Article  Google Scholar 

  13. Jia, L.C., Chen, S.L., Bai, Z.L., et al., Correction model and accelerating algorithm for ultrasonic total focusing method, Chin. J. Sci. Instrum., 2017, vol. 38, pp. 1589–1596.

    Google Scholar 

  14. Peng, H., Study on ultrasonic phased array full matrix capture imaging technique for CRH wheel set, Doctoral (Med.) Dissertation, Chengdu: Southwest Jiaotong University, 2014.

  15. Peng, H., Peng, J.P., Zhu, H.N., et al., The efficiency optimization of full matrix capture imaging detection based on increasing the effective aperture, Proc. 2014 IEEE Far East Forum Nondestr. Evaluation/Testing, Chengdu, 2014, pp. 44–49.

  16. Hu, H.W., et al., Ultrasonic phased array sparse – tfm imaging based on sparse array optimization and new edge – directed interpolation, Sensors, 2018, vol. 18.

  17. Zhang, H., et al., Lamb waves topological imaging combining with Green’s function retrieval theory to detect near filed defects in isotropic plates, Chin. Phys. B, 2019, vol. 28.

Download references

Funding

This work was supported by the National Natural Science Foundation of China (NSFC 52075270); Key scientific research projects and soft science research projects of military-civilian integration in Inner Mongolia Autonomous Region (JMZD202209); Science and Technology Plan Project of Inner Mongolia (2020GG0160); Supported By Program for Young Talents of Science and Technology in Universities of Inner Mongolia Autonomous Region(NJYT22063); and Natural Science Foundation of Inner Mongolia (2022MS05006).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shaofeng Wang.

Ethics declarations

The authors declare that they have no conflicts of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, J., Wang, S., Mao, X. et al. Accelerating Algorithm for Total Focusing Method Imaging Based on Optimization of Full Matrix Data. Russ J Nondestruct Test 59, 161–170 (2023). https://doi.org/10.1134/S1061830922600642

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1061830922600642

Keywords:

Navigation