Abstract

The optimal structural scheme and special features of the new automated plant for magnetic nondestructive testing of electric-welded pipes in a technological industrial line, which meets contemporary demands, are considered. It has been shown that the use of computer technologies and thin-filmed high-resolution transducers provides significant improvement of operating possibilities of a flaw detector and makes it possible to detect, not only such flaws as discontinuities in metal and displacement of edges, but also flaws caused by failures in welding regimes, such as burns and cohesion of edges near a welded joint.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Pashkov, Yu.N., Problems of Strength, Fracture, and Service Life of Tubes and Pipelines, Tematicheskii Sbornik Nauchnykh Trudov OAO RosNITI (Proceedings of OAO ROSNITI), Chelyabinsk, 2001, pp. 58–79.

  2. Bulychev, O.A., Magnetic Resistive Probe for Reading Information from Magnetic Media, RF Patent no. 2175455, Byull. Izobret., 2001, no. 30.

  3. Bulychev, O.A. and Shleenkov, A.S., Two-Component Matrix Probe of Magnetic Field, RF Patent no. 2290654, Byull. Izobret., 2006, no. 36.

  4. Shleevnkov, A.S., Development of Matrix Probes of Magnetic Field Applied to Nondestructive Testing of Ferromagnetic Specimens and Welded Joins, Doctor. Sci. Dissertation, Yekaterinburg: Institute of Metal Physics, Ural Division, Russian Academy of Sciences, 1998.

    Google Scholar 

  5. Zerstorungfreie Fehler-und Qualitatsprufung mit Wilberstrom-und Streuflussverfahren, — Gerate-Katalog Institute Dr. Forster, Reutlingen. 49 S.

  6. Stationary Setup for NDT “Vetcoscope C”, Manual Guide, Germany: Tuboscope Vetco GmbH, 1999.

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © A.S. Shleenkov, O.A. Bulychev, S.A. Shleenkov, 2008, published in Defektoskopiya, 2008, Vol. 44, No. 8, pp. 76–82.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Shleenkov, A.S., Bulychev, O.A. & Shleenkov, S.A. The UMD-101M plant for automated bulk magnetic nondestructive testing of quality of electric-welded pipes. Russ J Nondestruct Test 44, 574–578 (2008). https://doi.org/10.1134/S106183090808010X

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S106183090808010X

Keywords

Navigation