Abstract
Results of experimental investigation into the detection of internal, surface, and subsurface flaws by ultrasonic vibration pulses that are excited and received via different types of EMATs are reported. The sensitivity of the EMA instruments developed is shown to be close to the sensitivity of modern contact flaw detectors. An EMAT and a flaw detector that take advantage of the EMA flaw-detection method for the inspection of surface and near-surface zones of metal products are developed.
Similar content being viewed by others
References
Nerazrushayushchii kontrol’. Spravochnik: v 7 t (Handbook on Nondestructive Testing in 7 vols.: Ultrasonic Testing) V.V. Klyuev, I.N.-, Ermolov, and Yu.V. Lange, Eds., Moscow: Mashinostroenie, 2004, vol. 3.
Suchkov, G.M., The Main Advantage of the Electromagnetic-Acoustic Testing Technique, Defektoskopiya, 2000, no. 10, pp. 67–70 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2000, vol. 36, no. 10, p. 760].
Ermolov, I.N., Teoriya i praktika ul’trazvukovogo kontrolya (The Theory and Applications of Ultrasonic Testing), Moscow: Mashinostroenie, 1981.
Muzhitskii, V.F., Remezov, V.B., and Komarov, V.A., Fundamentals of Electromagnetic-Acoustic-Transformation Thickness Measurements with Attachable Probes: 1. Direct Electromagnetic-Acoustic Transformation in a Normal Polarizing Field, Defektoskopiya, 2006, no. 10, pp. 40–58 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2006, vol. 42, no. 10, p. 667].
Suchkov, G.M., Electromagnetic-Acoustic Method for Studying the Detectability of Flat-Bottom Reflectors in Samples of Various Materials, Kontrol’. Diagnostika, 2002, no. 5, pp. 50–51.
Suchkov, G.M., Designing Instruments for Ultrasonic Testing and Measurements Using Electromagnetic-Acoustic Method of Exciting and Receiving Ultrasonic Pulses, Tekh. Diagnost. Nerazrush. Kontrol’, 2005, no. 2, pp. 36–39.
Suchkov, G.M., The Capabilities of Modern EMA Thickness Gages, Defektoskopiya, 2004, no. 12, pp. 16–25 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2004, vol. 40, no. 12, p. 801].
Suchkov, G.M., State-of-the-Art Capabilities of EMA Flaw Detection, Defektoskopiya, 2005, no. 12, pp. 24–39 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2005, vol. 41, no. 12, p. 790].
Astaf’ev, A.N., Nevolin, O.V., Mamai, A.M., et al., A Universal Attachment for Standard Ultrasonic Flaw Detectors and Thickness Gages, Defektoskopiya, 2006, no. 7, pp. 73–82 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2006, vol. 42, no. 7, p. 474].
Kirikov, A.V., Zabrodin, A.N., and Komlik, A.V., Methods and Tools for Ultrasonic Testing of Roll Stock with the Use of Electromagnetic-Acoustic Transducers, V Mire Nerazrush. Kontrol. 1999, no. 3, pp. 18–20.
Suchkov, G.M., Development of the Theory and Applications in Designing Instruments for Electromagnetic-Acoustic Testing of Metal Products, Doctoral Dissertation, Nat. Tekh. Univ. “Khar’kovskii politekhnicheskii institut,” Khar’kov, 2005.
Sebko, V.P., Suchkov, G.M., and Malakhov, A.V., Ultrasonic Testing of Railheads Using the Electromagnetic-Acoustic Method, Defektoskopiya, 2004, no. 7, pp. 17–25 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2004, vol. 40, no. 7, p. 442].
Gordelii, V.I. and Chabanov, V.E., Designing of Angle Electromagnetic-Acoustic Transducers, Tekh. Diagnost. Nerazrush. Kontrol’, 2006, no. 2, pp. 30–32.
Suchkov, G.M., Suchkov, G.M., Information Processing. Possibility of Correlation Analysis in Thickness Measuring by the Electromagnetic-Acoustic Method, Kontrol’. Diagnostika, 2002, no. 8, pp. 37–40.
Suchkov, G.M., Information Processing. Improving Feasibility of the Correlation Analysis in Electromagnetic-Acoustic Instruments, Kontrol’. Diagnostika, 2004, no. 12, pp. 13–16.
Author information
Authors and Affiliations
Additional information
Original Russian Text © G.M. Suchkov, A.V. Donchenko, 2007, published in Defektoskopiya, 2007, Vol. 43, No. 6, pp. 43–50.
Rights and permissions
About this article
Cite this article
Suchkov, G.M., Donchenko, A.V. Real sensitivity of EMA instruments. Russ J Nondestruct Test 43, 384–389 (2007). https://doi.org/10.1134/S1061830907060058