Abstract
The possibility of using single-sided photon injection to reconstruct a tested object structure on the basis of the intensity of backscattered noncollimated radiation is considered. The reconstruction algorithm is based on statistical simulation of the interaction between radiation and a homogenous object, whose geometry is adequate for that of the tested object. The results of reconstruction are discussed.
Similar content being viewed by others
References
Gorshkov, V.A., A Tomograph on Noncollimiated Scattered Radiation, Defektoskopiya, 1999, no. 9, pp. 22–28.
Gorshkov, V.A., Kröning, M., Anosov, Yu.V., and Dzhogrochoo, O., Tomografiya na rasseyannom nekollimirovannom izluchenii (Tomography on Scattered Noncollimated Radiation), Moscow: Tekhnopoligraftsentr, 2002.
Gorshkov, V.A., Kröning, M., Anosov, Y.V., Kuzelev, N.R., Yumashev, V.M., Samossadny, V.T., and Miloserdin, V.Yu., X-ray Tomography on the Base of Noncollimated Radiation, Computer Tomography and Image Processing for Industrial Radiology, Berlin: 2003, p. 9.
Roye, W., Niemann, W., and Fischer, K.-H., The X-ray Backscattering Tomography ComScan, Int. Symposium on Computerized Tomography for Industrial Application, Berlin: 1994, pp. 136–140.
Gorshkov, V.A., Kuzelev, N.R., Anosov, Yu.V., Yumashev, V.M., Miloserdin, V.Yu., and Samosadnyi, V.T., Detection of Infantry-Protection Bombs Using a Tomograph on Backscattering Noncollimated Irradiation, 3-ya mezhdunarodnaya konferentsiya “Nerazrushayushchii kontrol’ i tekhnicheskaya diagnostika v promyshlennosty” (3d Int. Conf. on Nondestructive Testing and Technical Diagnostics in Industry), Moscow, 2004, pp. 169–170.
Leipunskii, O.I., Novozhilov, B.V., and Sakharov, V.N., Propagation of Gamma Quanta in Matter, Fiz. Met. Metalloved., 1960, p. 207.
Gorshkov, V.A., Method of Tomographic Evaluation of Density Distribution and Effective Atomic Number in Matter, RF Patent no. 2168717, 2001, p. 5.
Gorshkov, V.A., Tomographic Reconstruction of Distributions of Effective Atomic Numbers of Light Elements, Defektoskopiya, 2001, no. 9, pp. 73–80 [Rus. J. of Nondestructive Testing (Engl. Transl.), 2001, vol. 37, no. 9, p. 660].
Author information
Authors and Affiliations
Additional information
Original Russian Text © V.A. Gorshkov, M. Kröning, K. G. Kirilenko, 2006, published in Defektoskopiya, 2006, Vol. 42, No. 12, pp. 41–51.
Rights and permissions
About this article
Cite this article
Gorshkov, V.A., Kröning, M. & Kirilenko, K.G. Tomography based on detection of noncollimated backscattered radiation after single-sided photon injection. Russ J Nondestruct Test 42, 802–809 (2006). https://doi.org/10.1134/S1061830906120059
Received:
Issue Date:
DOI: https://doi.org/10.1134/S1061830906120059