Skip to main content
Log in

Permanent magnet wigglers for reducing the emittance of the Petra III synchrotron radiation source

  • Proceedings of XVIII International Conference on the Application of Synchrotron Radiation SR-2010 (Budker INP SB RAS, Novosibirsk, Russia)
  • Published:
Journal of Surface Investigation. X-ray, Synchrotron and Neutron Techniques Aims and scope Submit manuscript

Abstract

The Petra III synchrotron radiation source was developed based on the Petra-II 6-GeV electron accelerator (DESY). After installing the system for radiation damping, the horizontal emittance of the electron beam of Petra III decreased from 5 nm rad to 1 nm rad, which is a record parameter for this class of installations. The system of radiation damping includes 20 permanent magnet wigglers installed in two straight sections, 50 m each. The total radiation power of the wigglers reaches 800 kW. The wigglers used in the radiation damping system of Petra III were developed in collaboration with DESY (Hamburg) and fabricated by the Budker Institute of Nuclear Physics. The wiggler length is 4.04 m, the gap between the poles is 24 mm, the maximum magnetic field is B = 1.52−1.56 T, and the period is λ = 20 cm. This paper describes the design features of the permanent magnet wigglers and the methods and results of adjustment of the wiggler operating parameters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. M. Vinokurov, Nucl. Instrum. Methods Phys. Res. A 246, 105 (1986).

    Article  Google Scholar 

  2. A. M. Batrakov, I. V. Il’in, D. S. Shichkov, et al., Nucl. Instrum. Methods Phys. Res. 575, 50 (2007).

    Article  CAS  Google Scholar 

  3. A. M. Batrakov, I. V. Il’in, D. S. Shichkov, et al., Nucl. Instrum. Methods Phys. Res. 575, 46 (2007).

    Article  CAS  Google Scholar 

  4. A. Batrakov, S. Zverev, I. V. Il’in, et al., Preprint No. 2007-32 (Budker INP, Novosibirsk, 2007).

    Google Scholar 

  5. E. I. Antokhin, A. M. Batrakov, P. D. Voblyi, et al., Preprint No. 2002-46 (Inst. Yad. Fiz., Novosibirsk, 2002).

    Google Scholar 

  6. A. M. Batrakov, P. V. Vagin, P. D. Voblyi, et al., Preprint No. 2008-26 (Inst. Yad. Fiz., Novosibirsk, 2008).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. V. Utkin.

Additional information

Original Russian Text © A.M. Batrakov, P.V. Vagin, P.D. Vobly, D.S. Gurov, N.I. Zubkov, I.V. Ilyin, A.B. Ogurtsov, M. Tischer, A.V. Utkin, N.G. Khavin, M.A. Kholopov, D.S. Shichkov, 2011, published in Poverkhnost’. Rentgenovskie, Sinkhrotronnye i Neitronnye Issledovaniya, 2011, No. 11, pp. 18–25.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Batrakov, A.M., Vagin, P.V., Vobly, P.D. et al. Permanent magnet wigglers for reducing the emittance of the Petra III synchrotron radiation source. J. Surf. Investig. 5, 1038–1044 (2011). https://doi.org/10.1134/S1027451011110048

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1027451011110048

Keywords

Navigation