Skip to main content
Log in

Voltammetric Determination of Tibolone on a Nano-Composite Electrode

  • Published:
Russian Journal of Electrochemistry Aims and scope Submit manuscript

Abstract

In this work, very simple and swift method for the assessment of synthetic steroid Tibolone, which was banned by World Anti-Doping Agency (WADA) has been developed. A glassy carbon electrode modified with CuO nanoparticles and multi-walled carbon nanotubes was used. The effect of scan rate, pH of the medium, and concentration of nano-suspension has been studied using cyclic voltammetry in 0.1 M phosphate buffer solution. Linear sweep voltammetry was used for the quantification of Tibolone. The modified electrodes shows linearity range of 15 to 80 μM Tibolone with limit of detection of 1.05 μM and limit of quantification of 3.51 μM, respectively. Further the present method was successfully applied to determine Tibolone in pharmaceutical formulations and urine sample.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.

REFERENCES

  1. Siavash, S. and Masoud, R.S., Electrochemical determination of cisplatin at modified carbon paste electrode with graphene nano sheets/gold nano particles and a hydroquinone derivative in biological samples, Russ. J. Electrochem., 2021, vol. 57, p. 1224.

    Article  Google Scholar 

  2. Deniz, A.A. and Servet, C., A new surface based on graphene modified with nanoparticles and nafion for the detection of glucose, Russ. J. Electrochem., 2021, vol. 57, p. 1186.

    Article  Google Scholar 

  3. De, P.B., Giada, F., Benettin, A., Sartori, F., and Piccolo, E., Anabolic steroid use in body builders: an echocardiographic study of left ventricle morphology and function, Int. J. Sports. Med., 1991, vol. 12, no. 4, p. 408.

    Article  Google Scholar 

  4. de Jongh, H.P. and Van, V.N.P., US Patent 3340279, 1967.

  5. Portela, L.A., Laurito, T.L., Beatrice, S., Perissutti, E., Mendes, G.D., Moreno, R.A., and De, N.G., Quantification of 3α-hydroxytibolone in human plasma by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS): application in a bioequivalence study in healthy postmenopausal volunteers, Anal. Chem. Res., 2016, vol. 8, p. 16.

    Article  CAS  Google Scholar 

  6. The World Anti-Doping Agency, Prohibited List – January 2022-WADA, 2022.

  7. Celotti, F. and Cesi, P.N., Anabolic steroids: a review of their effects on the muscles, of their possible mechanisms of action and of their use in athletics, J. Steroid Biochem. Mol. Biol., 1992, vol. 43, p. 469.

    Article  CAS  PubMed  Google Scholar 

  8. Anthony, J.O., Michael, C.K., John, H.C., Richard, O.D., Brian, C., and Alex, D.W., Anabolic-androgenic steroids: medical assessment of present, past and potential users, Med. J. Aust., 1997, vol. 173, no. 6, p. 323.

    Google Scholar 

  9. da Silva, P.R.P., Danielski, R., and Czepielewski, M.A., Anabolic steroids in sports, Rev. Bras. Med., 2002, vol. 8, p. 235.

    Google Scholar 

  10. Son, J., Moon, J.Y., Kim, S.A., Cho, Y.D., Kim, J.D., Kim, D.H., and Choi, M.H., Improved detectability in pharmacokinetic study of tibolone by gas chromatography-high resolution mass spectrometry with selected ion monitoring, Talanta, 2006, vol. 70, p. 37.

    Article  CAS  PubMed  Google Scholar 

  11. Zuo, M., Gao, M.J., Liu, Z., Cai, L., and Duan, G.L., p-Toluenesulfonyl isocyanate as a novel derivatization reagent to enhance the electrospray ionization and its application in the determination of two stereo isomers of 3-hydroxyl-7-methyl-norethynodrel in plasma, J. Chromatogr. B, 2005, vol. 814, p. 331.

    Article  CAS  Google Scholar 

  12. Cardoso, F.F.S.S., César, I.C., Mundim, I.M., Teixeira, L.S., Silva, E.P., Bonfim, R.R., Gomes, S.A., Ferreira, D.P., Lopes, A.R.B., Pascoal, H.D., Souza, W.C., and Pianetti, G.A., Determination of 3-α-hydroxytibolone in human plasma by LC-MS/MS: application for a pharmacokinetic study after administration of a tibolone formulation, Biomed. Chromatogr., 2013, vol. 27, p. 1457.

    Article  CAS  Google Scholar 

  13. Weberson, P.S., Raquel, G.R., John, K.R.P.F., Raquel, M.F.S., Rodrigo, A.A.M., and Eduardo, M.R., Electrochemical determination of the steroid tibolone and its metabolites in saliva samples, Chem. Electro. Chem., 2020, vol. 7, p. 4469.

    Google Scholar 

  14. Darezereshki, E. and Bakhtiari, F., A novel technique to synthesis of tenorite (CuO) nanoparticles from low concentration CuSO4 solution, J. Min. Metall. Sect. B-Metall., 2011, vol. 47, no. 1, p. 73.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. N. Hegde.

Ethics declarations

CONFLICT OF INTEREST

Authors announce that there is no conflict of interest.

FINANCIAL SUPPORT

This work was carried out with the financial support of Vision Group on Science and Technology, Government of Karnataka, India (VGST/RGS-F/GRD-923/2019-20/2020-21/198 dated 10-11-2020).

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hegde, R.N., Vishwanatha, P. & Nandibewoor, S.T. Voltammetric Determination of Tibolone on a Nano-Composite Electrode. Russ J Electrochem 59, 320–324 (2023). https://doi.org/10.1134/S1023193523040080

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S1023193523040080

Keywords:

Navigation