Abstract
The poly-glutamic acid modified electrode has been prepared by direct electro-polymerization of D-glutamic acid on the surface of glassy carbon electrode. In pH 4.2, 0.1 mol L−1 HAc-NaAc buffer solution, the film modified electrode exhibited remarkable enhancement effect to the electrochemical responses of ferulic acid. The action mechanism was preliminarily explored. In the range of 2.0 × 10−7 to 1.0 × 10−5 mol L−1, and 1.0 × 10−5 to 3.0 × 10−4 mol L−1, the oxidation peak current has a linear relationship to the concentration, and the detection limit was estimated to be 7.0 × 10−8 mol L−1. This method has been adopted to detect trace amount of ferulic acid in Chinese proprietary medicine, and the recovery was from 97.8 to 102.4%.
Similar content being viewed by others
References
Zheng, H.Z., Dong, Z.H., and She, Q., Modern Research and Application of Traditional Chinese Medicine, Beijing: Xueyuan Press, 1998, p. 225.
Ou, H.Y., Bao, H.Y., and Lan, Z.D., J. Chin. Med. Mater., 2001, vol. 24, p. 220.
Sohn, N.T. and Oh, J.H., Arch. Pharm. Res., 2003, vol. 26, p. 100.
Li, Y.J. and Bi, K.S., Biomed. Chromatogr., 2003, vol. 17, p. 543.
Li, X.P., Yu, J., Luo, J.Y, et al., Chem. Pharm. Bull., 2004, vol. 52, p. 1251.
Prakash, H.O., Krishan, B.T., and Bhupinder, S., J. Chromatogr., 1998, vol. 822, p. 167.
Holland, L.A., Harmony, N.M., and Lunte, S.M., Electroanalysis, 1999, vol. 11, p. 327.
Li, L.N., Li, N.B., and Luo, H.Q., Anal. Sci., 2005, vol. 21, p. 963.
Wang, H.Y., Li, Y.F., and Huang, C.Z., Talanta, 2007, vol. 72, p. 1698.
Trabelsi, S.T., Tahar, N.B., and Abdelhedi, R., J. App. Electrochem., 2005, vol. 35, p. 967.
Ai, Z., Liao, F., Zhu, L., et al., Chin. J. App. Chem., 2006, vol. 23, p. 566.
Yu, Y.Y., Wu, Q.S., Wang, X.G., et al., Russ. J. Electrochem., 2009, vol. 45, p. 170.
Li, L.J., Yu, L.B., Chen, Q.F. et al., Chin. J. Anal. Chem., 2007, vol. 35, p. 933.
Yu, A.M. and Chen, H.Y., Analytical Letters, 1997, vol. 30, p. 599.
Yu, A.M. and Chen, H.Y., Anal. Chim. Acta, 1997, vol. 344, p. 181.
Wang, L., Huang, P.F, and Bai, J.Y., Int. J. Electrochem. Sci., 2007, vol. 2, p. 123.
Zhang, Y.Z., Zhang, K.Y., and Ma, H.Y., Am. J. Biomed. Sci., 2009, vol. 1, p. 115.
Zhang, Y., Luo, L.Q., Ding, Y.P., et al., Microchim. Acta, 2010, vol. 171, p. 133.
Zhou, N., Yang, T., Zhang, Y.C., et al., Thin Solid Films, 2009, vol. 518, p. 338.
Santos, D.P., Zanoni, M.V.B., Bergamini, M.F., et al., Electrochimica Acta, 2008, vol. 53, p. 3991–4000.
Deinhammer, R.S., Ho, M., Anderegg, J.W., and Porter, M.D., Langmuir, 1994, vol. 10, p. 1306.
Laviron, E., J. Electroanal. Chem., 1974, vol. 52, p. 355.
Pharmacopoeia of People’s Republic of China, The State Pharmacopoeia Commission of People’s Republic of China, Beijing: Chemical Industry Press, 2005, p. 126.
Xie, J.B., Wang, W.Q., Zhang, Y.Q., et al., J. Pharm. Biomed. Anal., 2007, vol. 45, p. 450.
Xu, Y., Tan, H., and Wan, X., Chin. Pharm. J., 2001, vol. 36, p. 552.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published in Russian in Elektrokhimiya, 2012, Vol. 48, No. 12, pp. 1272–1278.
The article is published in the original.
Rights and permissions
About this article
Cite this article
Wang, XG., Li, J., Fan, YJ. et al. Determination of ferulic acid in Chinese proprietary medicine based on a poly-glutamic acid film sensor. Russ J Electrochem 48, 1160–1165 (2012). https://doi.org/10.1134/S1023193512120142
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1023193512120142