A new salicylate-selective electrode based on the complex (2,3;6,7;10,11;14,15-tetraphenyl-4,9,13,16-tetraoxo-1,5,8,12-tetraazacyclohexadecane) copper(II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of −60.9 ± 1.0 mV/decade and a linear range from 1.0 × 10−6 to 1.0 × 10−1 M for salicylate. The detection limit is 5.0 × 10−7 M. The electrode has a fast response time (5–15 s) and can be used for more than three months. The selective coefficients were determined by the fixed interference method (FIM) and separate solution method (SSM). The salicylate-selective electrode could be used in the pH range 3.5–10.5. It was employed as an indicator electrode for direct determination of salicylate in pharmaceutical samples.
Similar content being viewed by others
References
MacMahon, G.P. and Kelly, M.T., Anal. Chem., 1998, vol. 70, p. 409.
Trinder, P., Biochem. J., 1954, vol. 57, p. 301.
Moore, T.J., Joseph, M.J., Allen, W.B., and Coury, L.A., Anal. Chem., 1995, vol. 67, p. 1869.
MacMahon, G.P., O’Connor, S.J., Fitzgerald, D.J., Roy, S.L., and Kelly, M.T., J. Chromatogr., Ser. B, 1998, vol. 48, p. 469.
Navalon, A., Blanc, R., Olmo, M.D., and Vilchez, J.L., Talanta, 1999, vol. 48, p. 469.
Lloyed, J.B.F., Analyst, 1978, vol. 103, p. 775.
Arnaud, N. and Georges, J., Analyst, 1999, vol. 124, p. 1075.
Hutchins, R.S., Bansal, P., Molina, P., Alajarin, M., Vidal, A., and Bachas, L.G., Anal. Chem., 1997, vol. 69, p. 1273.
Chaniotakis, N.A., Park, S.B., and Meyerhoff, M.E., Anal. Chem., 1989, vol. 61, p. 566.
Creager, S.E., Lawrence, K.D., and Tibbets, C.R., J. Chem. Educ., 1995, vol. 72, p. 274.
Hisamoto, H., Siswanta, D., Niashara, H., and Suzuki, K., Anal. Chim. Acta, 1995, vol. 304, p. 171.
Katso, T. and Mori, Y., Talanta, 1996, vol. 43, p. 755.
Rover, L., Garcia, C.A.B., Neto, G.D.O., Kubota, L.T., and Galembeck, F., Anal. Chim. Acta, 1998, vol. 366, p. 103.
Shakir, M., Mohamed, A.K., and Nasman, O.S.M., Polyhedron, 1996, vol. 15, p. 3487.
Kamata, S., Bhal, A., Fakunaga, Y., and Marata, A., Anal. Chem., 1998, vol. 60, p. 2464.
Bakker, E., Pretsch, E., and Buhlmann, P., Anal. Chem., 2000, vol. 72, p. 1127.
Umezawa, Y., Umezawa, K., and Sato, H., Pure Appl. Chem., 1995, vol. 67, p. 507.
Morf, W.E., Khar, G., and Simon, W., Anal. Lett., 1974, vol. 7, p. 9.
Huser, M., Gehrlg, P.M., Morf, W.E., Simon, W., Lindner, C., Jeney, J., Toth, K., Pungor, E., Anal. Chem., 1991, vol. 63, p. 1380.
Schaller, U., Bakker, E., Spichiger, U.E., and Pretsch, E., Anal. Chem., 1994, vol. 66, p. 391.
Bakker, E., Malinowska, E., Schiller, R.D., and Meyerhoff, M.E., Talanta, 1994, vol. 41, p. 881.
Bühlmann, P., Yajima, S., Tohda, K., Umezawa, K., Nishizawa, S., and Umezawa, Y., Electroanalysis, 1995, vol. 7, p. 811.
Yajima, S., Tohda, K., Bühlmann, P., and Umezawa, Y., Anal. Chem., 1997, vol. 69, p. 1919.
Amemiya, S., Buhlmann, P., Pretsch, E., Rusterholz, B., and Umezawa, Y., Anal. Chem., 2000, vol. 72, p. 1618.
Bakker, E., Bühlmann, P., and Pretsch, E., Chem. Rev., 1997, vol. 97, p. 3083.
Schaller, U., Bakker, E., and Pretsch, E., Anal. Chem., 1995, vol. 67, p. 3123.
Buck, R.P. and Lindner, E., Pure Appl. Chem., 1994, vol. 66, p. 2527.
Srinivasan, K. and Rechnitz, G.A., Anal. Chem., 1969, vol. 41, p. 1203.
Badr, I.H.A., Meyerhoff, M.E., and Hassan, S.S.M., Anal. Chem., 1995, vol. 67, p. 2613.
Morf, W.E., The Principles of Ion-Selective Electrodes and of Membrane Transport, Budapest: Akadèmiai Kiaddö; Amsterdam: Elsevier, 1981.
Daunert, S., Wallace, S., Florido, A., and Bachas, L.G., Anal. Chem., 1991, vol. 63, p. 1676.
Leyzerovich, N.N., Shvedene, N.V., Bilkova, Y.N., and Tomilova, L.G., Electroanalysis, 2001, vol. 3, p. 246.
Shahrokhian, S., Hamzehloei, A., and Bagherzadeh, M., Anal. Chem., 2002, vol. 74, p. 3312.
Shahrokhian, S., Amini, M.K., Kia, R., and Tangestaninejad, S., Anal. Chem., 2000, vol. 72, p. 956.
Firooz, A.R., Amini, M.K., Tangestaninejad, S., and Shahrokhian, S., Anal. Lett., 2001, vol. 34, p. 661.
Mazloum Ardakani, M., Jalayer, M.S., Safari, J., Sadeghi, Z., and Zare, H.R., Anal. Biochem., 2005, vol. 341, p. 259.
Guangrong, Y.E., Yaqin, C., Yuan, R., Lu, Z., Yan, L., Lina, Anal. Sci., 2007, vol. 23, p. 171.
Xu, L., Yuan, R., and Zifu, Y., Qinchai, Anal. Sci., 2005, vol. 21, p. 287.
British Pharmacopoeia, Cambridge: University Press, 1993, vol. II.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published in Russian in Elektrokhimiya, 2008, Vol. 44, No. 9, pp. 1147–1154.
The text was submitted by the authors in English.
Rights and permissions
About this article
Cite this article
Mazloum Ardakani, M., Ebrahimi, P. & Mansournia, M.R. The complex (2,3;6,7;10,11;14,15-tetraphenyl-4,9,13,16-tetraoxo-1,5,8,12-tetraazacyclohexadecane) copper(II) as a carrier for a salicylate-sensitive poly(vinylchloride) membrane electrode. Russ J Electrochem 44, 1065–1072 (2008). https://doi.org/10.1134/S1023193508090127
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S1023193508090127