Experimental study on the heat and mass transfer characteristics of a counter-flow wet cooling tower with foam ceramic packing

  • Q. J. KongEmail author
  • D. Y. Liu
  • P. Wang
  • D. Q. Xie
  • Q. Wu
  • X. Y. Zhao
Article
  • 10 Downloads

Abstract

An experimental investigation of coinstantaneous heat and mass transfer phenomena between water and air in a counter flow wet cooling tower filled with a new type packing named “FCP-08” is presented in this paper. The packing consisted of foamed ceramic corrugated board with sine waves and surface retention groove is 1.0 m high and have a cross sectional test area of 0.68×0.68 m2. The present investigation is focused mainly on the effect of the water/air mass flow ratio on the heat and mass transfer characteristics of the cooling tower, for different inlet water temperatures. The results show that the cooling water range R and the cooling tower efficiency e decrease with the increase of water/air mass flow ratio L/G. Meanwhile, the cooling characteristic coefficient KαV/L slightly decreases with the increase of water/air mass flow ratio and the value is obviously higher than that of other packing investigated before. The expression of cooling characteristic coefficient related to water/air mass flow ratio and inlet water temperature is obtained by linear fitting. The comparison between the obtained results and those found in the literature for other types of packing indicates that cooling performance of the tower with foam ceramic packing is better.

Key words

cooling tower heat and mass transfer characteristics foam ceramic packing water/air mass flow ratio cooling performance 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    F. Gharagheizi, R. Hayati, and S. Fatemi, Experimental study on the performance of mechanical cooling tower with two types of film packing, Energy Conversion & Management, 2007, Vol. 48, P. 277–280.CrossRefGoogle Scholar
  2. 2.
    W.M. Simpson and T.K. Sherwood, Performance of small mechanical draft cooling towers, Amer. Soc. Refrigerating Engineers, 1946, Vol. 52, P. 535–543.Google Scholar
  3. 3.
    J.E. Braun, Methodologies for the design and control of central cooling plants, PhD thesis, Mechanical engineering, University of Wisconsin-Madison, Madison, 1988.Google Scholar
  4. 4.
    H. El-Dessouky, Thermal and hydraulic performance of a three-phase fluidized bed cooling tower, Experim. Thermal Fluid Sci., 1993, Vol. 6, P. 417–426.CrossRefGoogle Scholar
  5. 5.
    S.V. Bedekar, P. Nithiarasu, and K.N. Seetharamu, Experimental investigation of the performance of a counter flow packed-bed mechanical cooling tower, Energy, 1998, Vol. 23, No. 11, P. 943–947.CrossRefGoogle Scholar
  6. 6.
    H.R. Goshayshi, J.F. Missenden, and R. Tozer, Cooling towers — an energy conservation resource, Applied Thermal Engng, 1999, Vol. 19, P. 1223–1235.CrossRefGoogle Scholar
  7. 7.
    H.R. Goshayshi and J.F. Missenden, The investigation of cooling tower packing in various arrangements, Appl. Thermal Engng, 2000, Vol. 21, P. 69–80.CrossRefGoogle Scholar
  8. 8.
    E. Elsarrag, Experimental study and predictions of an inclined draft ceramic tile packing cooling tower, Energy Conversion & Management, 2006, Vol. 47, P. 2034–2043.CrossRefGoogle Scholar
  9. 9.
    M. Lemouari, M. Boumaza, and A. Kaabi, Experimental analysis of heat and mass transfer phenomena in a direct contact evaporative cooling tower, Energy Conversion & Management, 2009, Vol. 50, P. 1610–16177.CrossRefGoogle Scholar
  10. 10.
    A.N. Pavlenko, J. Zeng, N.I. Pecherkin, V.E. Zhukov, and O.A. Volodin, Separation efficiency and pressure drop of SiC ceramic and Mellapak structured packings, J. Engng Thermophys., 2016, Vol. 25, No. 1, P. 1–14.CrossRefGoogle Scholar
  11. 11.
    X. Li, Q. Shi, H. Li, Y. Yao, A.N. Pavlenko, and X. Gao, Experimental characterization of novel SiC foam corrugated structured packing with varied pore size and corrugation angle, J. Engng Thermophys., 2017, Vol. 26, No. 4, P. 452–465.CrossRefGoogle Scholar
  12. 12.
    F.C. Buciuman and B. Kraushaar-Czarnetzki, Ceramic foam monoliths as catalyst carriers. P. 1. Adjustment and description of the morphology, Industrial & Engng Chemistry Res., 2003, Vol. 42, P. 1863–1869.CrossRefGoogle Scholar
  13. 13.
    K. Seongyup and M.A. Deshusses, Determination of mass transfer coefficients for packing materials used in biofilters and biotrickling filters for air pollution control. P. 2. Development of mass transfer coefficients correlations, Chemical Engng Sci., 2008, Vol. 63, P. 856–861.CrossRefGoogle Scholar
  14. 14.
    Uncertainty of measurement. P. 3. Guide to the expression of uncertainty in measurement. 1995. ISO/IEC Guide 98-3, GUM.Google Scholar
  15. 15.
    J. Lichtenstein, Performance and selection of mechanical draft cooling towers, ASME Transfer, 1943, Vol. 65, P. 779–787.Google Scholar
  16. 16.
    V.F. Merkel, Verdunstungskühlung, Zeitschrift des Vereines Deutscher Ingenieure (VDI), 1925, Vol. 70, P. 123–128.Google Scholar
  17. 17.
    L.D. Berman, Evaporative Cooling of Circulating Water,: Gosenergoizdat, Moscow, 1965.Google Scholar
  18. 18.
    R.H. Perry, D.W. Green, and J.O. Maloney, Perry’s Chemical Engineers’ Handbook, 7th ed., McGraw-Hill, N.Y. etc., 1997.Google Scholar
  19. 19.
    Armfield Ltd., BASIC water cooling tower: engineering teaching and research equipment (instruction manual), 1993.Google Scholar
  20. 20.
    M. Lemouari, M. Boumaza, and I.M. Mujtaba, Thermal performances investigation of a wet cooling tower, Applied Thermal Engng, 2007, Vol. 27, P. 902–909.CrossRefGoogle Scholar
  21. 21.
    N.W. Kelly and L.K. Swenson, Comparative performance of cooling tower packing arrangements, Chemical Engineering Progress, 1986, Vol. 52, P. 263–268.Google Scholar
  22. 22.
    R.G. Barile, J.L. Dengler, and T.A. Hertwig, Performance and design of a turbulent bed cooling tower, AIChE Symposium Series, 1974, Vol. 70, No. 138, P. 154–162.Google Scholar
  23. 23.
    J.C. Kloppers and D.G. Kröger, Loss coefficient correlation for wet cooling tower fills, Appl. Thermal Engng, 2003, Vol. 23, P. 2201–2011.CrossRefGoogle Scholar

Copyright information

© Q.J. Kong, D.Y. Liu, P. Wang, D.Q. Xie, Q. Wu, and X.Y. Zhao 2019

Authors and Affiliations

  • Q. J. Kong
    • 1
    Email author
  • D. Y. Liu
    • 2
  • P. Wang
    • 2
  • D. Q. Xie
    • 3
  • Q. Wu
    • 3
  • X. Y. Zhao
    • 3
  1. 1.Jiangsu University of TechnologyChangzhou, JiangsuChina
  2. 2.Hohai UniversityNanjing, JiangsuChina
  3. 3.Hohai UniversityChangzhou, JiangsuChina

Personalised recommendations