Skip to main content
Log in

The Use of the Heat-Accumulation Properties of Heat-Supply Networks and Buildings for the Extension of the Electric Power Output Control Range at Combined Heat and Power Plants

  • DISTRICT HEATING COGENERATION AND HEAT-SUPPLY NETWORKS
  • Published:
Thermal Engineering Aims and scope Submit manuscript

Abstract

As a result of the lack of flexible capacities and an increase in the fraction of nuclear power plants in European Russia, the combined heat and power (CHP) plants currently need offloading during the off-peak hours of electric power demand. The adjustment of electric power demand necessitates additionally increasing the electric power of the power-generating units in the on-peak hours and decreasing it at nighttime. The existing methods for increasing the power of combined heat and power plants suffer from a number of serious drawbacks. The reduction in the electric power in the heating period is restricted, as a rule, by high heat demand. In this work, we show the possibility of extending the control range of the electric power output at CHP plants through the use of the heat-accumulation properties of the heat-supply networks and buildings and, accordingly, through the changeover of the operating modes of the cogeneration plant. Several operating-mode variants of the cogeneration plant are considered. The calculations conducted show that the consideration of the heat-accumulation properties of the heat-supply networks and buildings allows, having reduced the electric output of the CHP plant at nighttime, for an increase in the thermal output to increase the electric output in the day reducing the thermal output. An important requirement for the heat supply to buildings is the maintenance of comfortable indoor conditions. The optimal permissible temperature range for living space in the cold period of the year is 20–22°C. The possibility of ensuring the comfortable conditions indoors is confirmed by the calculations of the indoor air temperature by the method previously proposed by the authors that considers the heat-accumulation properties of the heat-supply networks and buildings. The indoor air temperature decreases by the end of the discharge period, i.e., the time when the accumulated heat has been consumed, to approximately 19°C; consequently, it does not go down below the permissible range. It should be noted that this is predominantly due to the heat-accumulation properties of the buildings. The material of the main heating system pipelines has a low accumulation capacity, i.e., the pipe walls transfer heat rapidly to the water that enters the pipeline at a temperature lower than that of the pipes. However, due to the considerable length of the heat system’s pipelines, the temperature of the heating-system water that arrives at the consumer remains constant at the time moment after the temperature perturbance on the heat source.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.
Fig. 8.
Fig. 9.

Similar content being viewed by others

REFERENCES

  1. https://studopedia.net/13_35499_rezhim-raboti-po-teplovomu-grafiku.html

  2. A. D. Trukhnii and B. V. Lomakin, Cogeneration Steam Turbines and Turbine Plants (Mosk. Energ. Inst., Moscow, 2017).

    Google Scholar 

  3. https://vunivere.ru/work24639/page36

  4. V. Ya. Girshfel’d, “Analysis of heat supply regimes at a heating combined heat and power plant with consideration of the uncertainty of the initial information,” Teploenergetika, No. 8, 48–52 (1988).

    Google Scholar 

  5. V. I. Panferov, “Identification of thermal regimes of pipeline systems,” Vestn. YuUrGU, Ser.: Stroit. Arkhit., No. 13 (53), 85–90 (2005).

  6. S. A. Ivanov, A. G. Batukhtin, and N. V. Goryachikh, “Some methods for making cogeneration stations more maneuverable,” Therm. Eng. 57, 892–896 (2010).

    Article  Google Scholar 

  7. V. Ya. Girshfel’d, A. M. Knyazev, and V. E. Kulikov, Thermal Power Plant Operation Modes and Conditions: Textbook (Energiya, Moscow, 1980) [in Russian].

    Google Scholar 

  8. R. Z. Aminov, Vector Optimization of Power Plant Operation Modes (Energoatomizdat, Moscow, 1994) [in Russian].

    Google Scholar 

  9. B. V. Yakovlev, Increasing the Efficiency of District Heating and Heat Supply Systems (Nov. Teplosnabzh., Moscow, 2008) [in Russian].

  10. R. Z. Aminov and E. Yu. Burdenkova, “Assessment of the effect of accumulating properties of heating networks on the delay of temperature changes at the consumer,” Tr. Akademenergo, No. 2, 38–45 (2016).

    Google Scholar 

  11. R. Z. Aminov and E. Yu. Burdenkova, “Assessment of the effect of the accumulating properties of heated buildings on the change in indoor air temperature,” Tr. Akademenergo, No. 2, 45–52 (2018).

    Google Scholar 

  12. R. Z. Aminov and E. Yu. Burdenkova, “Studying of possible operating modes in graphics of electric loads of combined heat and power plants taking into account heat-sink properties of thermal networks,” in Proc. Int. Multi-Conf. on Industrial Engineering and Modern Technologies (FarEastCon-2019), Vladivostok, Russia, Oct. 1–4, 2019 (IEEE, Piscataway, N. J., 2019), pp. 1–6. https://doi.org/10.1109/FarEastCon.2019.8934127

  13. The Standard Specified Characteristic of a Turbine Generator Unit T-100-130 (STsNTI ORGRES, Moscow, 1971).

  14. E. I. Benenson and L. S. Ioffe, Cogeneration Steam Turbines (Energoatomizdat, Moscow, 1986) [in Russian].

    Google Scholar 

  15. V. P. Isachenko, V. A. Osipova, and A. S. Sukomel, Heat Transfer (Energoatomizdat, Moscow, 1981; Mir, Moscow, 1981).

  16. E. Ya. Sokolov, District Heating Cogeneration and Heat Networks (Mosk. Energ. Inst., Moscow, 2001) [in Russian].

    Google Scholar 

  17. V. A. Petrushchenkov, “Substantiation of a lowered temperature schedule for regulating centralized heat supply systems,” Nov. Teplosnabzh., No. 8, 30–37 (2015).

  18. A. K. Tikhomirov, Heat Supply of a City District: Training Manual (Izd. Tikhookean. Gos. Univ, Khabarovsk, 2006) [in Russian].

    Google Scholar 

  19. V. I. Manyuk, Ya. I. Kaplinskii, E. B. Khizh, A. I. Manyuk, and V. K. Il’in, Adjustment and Operation of Water Heating Networks (Stroiizdat, Moscow, 1988) [in Russian].

    Google Scholar 

  20. GOST 30494-2011. Residential and Public Buildings. Parameters of Indoor Microclimate (Standartinform, Moscow, 2013).

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to R. Z. Aminov, E. Yu. Burdenkova or A. B. Moskalenko.

Additional information

Translated by O. Lotova

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aminov, R.Z., Burdenkova, E.Y. & Moskalenko, A.B. The Use of the Heat-Accumulation Properties of Heat-Supply Networks and Buildings for the Extension of the Electric Power Output Control Range at Combined Heat and Power Plants. Therm. Eng. 68, 584–591 (2021). https://doi.org/10.1134/S0040601521050037

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0040601521050037

Keywords:

Navigation