Skip to main content
Log in

The Damping Capacity of Damping Devices during Rotor-over-Stator Rolling

  • STEAM TURBINE, GAS TURBINE, AND COMBINED-CYCLE POWER PLANTS AND THEIR AUXILIARY EQUIPMENT
  • Published:
Thermal Engineering Aims and scope Submit manuscript

Abstract

The article presents results of investigating the influence of elastic damping devices that secure the rotor and the stator under high-amplitude oscillations under unfavorable development of an accident, e.g., upon rubbing of the rotor against the stator. Motion equations for the oscillations of the rotor in the clearance between the rotor and the stator and the oscillations of the rotor rubbing against the stator are written at adopted parameters of the stator considering not only the rigidity of the stator but also the energy losses under deformation of the stator components during the oscillations. Sudden unbalance of the rotor is taken as the initial excitation. A case of severe unbalance of the rotor is examined when, under oscillations accompanied by rubbing, the damping devices experience fairly severe strains in different rolling modes. The investigations were conducted using a rotor that had been affected by accidents accompanied by destruction of the bearings under rubbing in the absence of damping devices. A dynamic model of a symmetrical two-bearing rotor is considered. ADP-2400 shock absorbers served as dampers; the dynamic impact properties of the former had been determined using shock-testing machines. A possibility of the development of self-excited oscillations in the form of asynchronous rolling is considered depending on the absorption factor of the elastic damping devices. It is shown that no asynchronous rolling develops at definite absorption factor values. The oscillations of the rotor are restricted to the synchronous rolling at rotor–stator contact interaction forces that do not endanger the integrity of the turbine plant structure. The elastic damping devices with absorption factors above certain values eliminate the possibility of the development of self-excited oscillations in the form of asynchronous rolling and a practically unlimited increase in the rotor–stator interaction forces and, consequently, eliminate the danger of destruction (self-destruction) of the power-generating plant. In a sense, we can speak about the damping capacity of elastic damping devices during the evolution of an accident accompanied by rubbing of the rotor against the stator. The rigid mount of the stator on the foundation in the absence of damping devices increases the risk of the catastrophic development of the emergency considerably reducing the evolution time of the rolling and the possibility of using safety devices. A conceptual scheme that systemizes the general regulations for preventing TP accidents is provided.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.
Fig. 6.
Fig. 7.

Similar content being viewed by others

REFERENCES

  1. V. F. Shatokhin, “Patterns of the rotor-over-stator rolling under change in the damping components,” Therm. Eng. 65, 143–150 (2018). https://doi.org/10.1134/S0040601518030060

    Article  Google Scholar 

  2. A. G. Kostyuk, V. F. Shatokhin, and O. A. Volokhovskaya, “Motion of an imbalanced rotor when it rubs against the stator,” Therm. Eng. 59, 87–95 (2012).

    Article  Google Scholar 

  3. V. F. Shatokhin, Oscillations of Rotors with Rotor-Over-Stator Rolling (Methods of Mathematical Modeling and Software Tools) (Lambert Academic, Dusseldorf, 2016) [in Russian].

    Google Scholar 

  4. V. F. Shatokhin, “Forces exciting generation roll at rotor vibrations when rotor-to-stator rubbing,” Therm. Eng. 64, 480–489 (2017). https://doi.org/10.1134/S0040601517070072

    Article  Google Scholar 

  5. V. F. Shatokhin and S. D. Tsimmerman, “The predetermination of the development of the liquidation process of a turbine unit and examples of its consequences,” Aviats.-Kosm. Tekh. Tekhnol., No. 8, 95–102 (2007).

  6. I. Sh. Zagretdinov, A. G. Kostyuk, A. D. Trukhnii, and P. R. Dolzhanskii, “Destruction of the 300-MW turbine-generator unit at the Kashira district power station: Causes, consequences, and conclusions,” Therm. Eng. 51, 345–355 (2004).

    Google Scholar 

  7. V. F. Shatokhin and S. D. Tsimmerman, “Development of a unit catastrophe prevention system. Part 1: Analysis of catastrophic emergencies and statement of the problem,” Aviats.-Kosm. Tekh. Tekhnol., No. 10 (26), 19–31 (2005).

  8. V. I. Kiryukhin, A. V. Kiryukhin, V. F. Shatokhin, and E. A. Tsiklin, “Investigation of nonstationary oscillations of a multimass damped system with damping devices in the second cascade,” Vestn. Mashinostr., No. 9, 13–16 (2002).

  9. V. F. Shatokhin, “Numerical analysis of oscillations of the turbine unit in the case of a pulsed kinematic influence,” Vestn. Mashinostr., No. 8, 14–20 (2008).

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. F. Shatokhin.

Additional information

Translated by O. Lotova

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Shatokhin, V.F. The Damping Capacity of Damping Devices during Rotor-over-Stator Rolling. Therm. Eng. 66, 100–107 (2019). https://doi.org/10.1134/S004060151902006X

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S004060151902006X

Keywords:

Navigation