Skip to main content
Log in

Development of methods for the decrease in instability of recycling water of conjugated closed-circuit cooling system of HPP

  • Water Treatment and Water Chemistry
  • Published:
Thermal Engineering Aims and scope Submit manuscript

Abstract

On Russian HPPs, conjugated closed-circuit cooling systems, where purge water is used as initial for water-treatment facilities, are widespread. For this reason, it is impossible to use general methods for the stabilization treatment of recycling water in order to prevent scale formation in the units of a system, namely, turbine condensers and cooling towers. In this paper, the methods for the decrease in the instability of recycling water using the methods of chemical engineering, such as stabilization and synchronization of flows and organization of recycles, are suggested. The results of an industrial experiment on the implementation of stabilization treatment of recycling water by the organization of recycle are given. The experiment was carried out on Kazan CHPP-3. The flow scheme involved the recycle of chemically purified water (CPW) for the heat network make-up to the closed-circuit cooling system. The experiment was carried out at three stages with the gradual change of the consumption of the recycle, namely, 0, 50, and 100 t/h. According to the results of experiments, the reliable decrease in the rate of the sedimentation was recorded on the units of the system, namely, turbine condenser and chimney-type cooling tower. This is caused by two reasons. Firstly, this is periodic excessive concentration of recycling water due to the nonstationary character of inlet and outlet flows. Secondly, this is seasonal (particularly, in the summer period) exceeding of the evaporation coefficient. As a result of stabilization and synchronization of flows and organization of recycles, the quality of clarified and chemically purified water for the heat network make-up increases and the corrosion of iron- and copper-containing structural materials decreases. A natural decrease in temperature drop on the operating turbine condensers is mentioned.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Yu. M. Kostrikin, N. A. Meshcherskii, and O. V. Korovina, Water Treatment and Water Regime in Low- and Medium-Pressure Power Facilities (Energoatomizdat, Moscow, 1990) [in Russian].

    Google Scholar 

  2. A. A. Chichirov, N. D. Chichirova, I. I. Galiev, A. I. Murtazin, A.Yu. Smirnov, and M. A. Volkov, “Modeling and analysis of processes in functioning of circulating cooling system of TPPs,” Tr. Akademenergo, No. 2, 64–80 (2009).

    Google Scholar 

  3. A. A. Chichirov, N. D. Chichirova, I. I. Galiev, L. I. Gainutdinova, and A. Yu. Smirnov, “The study of composition and structure of sediments in the circulating cooling system of TPPs,” Izv. Vyssh. Uchebn. Zaved., Probl. Energ., Nos. 7–8, 37–45 (2009).

    Google Scholar 

  4. A. I. Murtazin, N. D. Chichirova, A. A. Chichirov, and S. M. Vlasov, “Determining the causes of sedimentation in technical water supply system of TPPs,” Izv. Vyssh. Uchebn. Zaved., Probl. Energ., Nos. 1-2, 41–45 (2012).

  5. RD 34.22.503-89. Methodical Instruction for Stabilization Treatment with Oxyethylidenediphosphonic Acid of Coolant Water in Circulating Cooling Systems with Cooling Towers (Ural’skii Filial Vyssh. Tekh. Inst. F. E. Dzerzhinskogo, Chelyabinsk, 1989) [in Russian].

  6. SO 34.37.536-2004. Methodic Recommendations for Application of Antisediments and Corrosion Inhibitors OEDFK, AFON 200-60A, AFON 230-23A, PAF-13a, IOMS-1 and Their Tested and Certified at RAO “EES Rossii” Analogues, by Power Utilities (EES Rossii, Moscow, 2004) [in Russian].

  7. V. N. Yurenev and P. D. Lebedev, Thermal Engineering Handbook (Energiya, Moscow, 1976), Vol. 2.

    Google Scholar 

  8. RD 153-34.1-30.311-96. Methodic Instruction on Conducting Express-Testing of Steam Turbines of TPPs (EES Rossii, Moscow, 1996) [in Russian].

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. M. Vlasov.

Additional information

Original Russian Text © A.A. Chichirov, N.D. Chichirova, S.M. Vlasov, A.I. Lyapin, R.Sh. Misbakhov, I.Yu. Silov, A.I. Murtazin, 2016, published in Teploenergetika.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chichirov, A.A., Chichirova, N.D., Vlasov, S.M. et al. Development of methods for the decrease in instability of recycling water of conjugated closed-circuit cooling system of HPP. Therm. Eng. 63, 747–753 (2016). https://doi.org/10.1134/S0040601516100025

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0040601516100025

Keywords

Navigation