Results from an experimental study of the local hydrodynamic structure of liquid flow in a 37-cell model simulating a fuel assembly used in the AES-2006 reactor are presented. Special attention is paid to the effect of spacer grid on flow hydrodynamics. Data on variations of the local and integral values of the liquid axial velocity and friction stress on the fuel rod simulator’s wall with distance from the grid are given.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. L. Kirillov, “Some Lines of Scientific Research in the Thermal Hydraulics of Nuclear Power Installations (Part I),” Therm. Eng., No. 3, 185 (2005).

  2. P. L. Kirillov, V. P. Bobkov, A. V. Zhukov, and Yu. S. Yur’ev, Thermal Hydraulic Processes in Nuclear Power Installations: A Handbook on Thermal-Hydraulic Calculations in Nuclear Power Engineering. Vol. 1, Ed. by P. L. Kirillov (IzdAT, Moscow, 2010) [in Russian].

    Google Scholar 

  3. S. Toth and A. Aszodi, “CHF Study on Coolant Mixing in VVER-440 Fuel Rod Bundles and Fuel Assembly Heads,” Nucl. Eng. and Design 240, 2194–2205 (2010).

    Article  Google Scholar 

  4. R. S. Pomet’ko and Yu. F. Selivanov, “Results from Studies of Heat Transfer and Coolant Mixing as Applied to VVER Reactors,” in Proceedings of the 3rd Scientific-Technical Conference “Ensuring Safety of Nuclear Power Stations Equipped with VVER Reactors,” OKB Gidropress, Podolsk, 2003.

    Google Scholar 

  5. S. M. Dmitriev, M. A. Legchanov, O. B. Samoilov, et al., “Specific Features of Local Hydrodynamics in Different Versions of Alternative Fuel Assemblies,” in Proceedings of the 2nd International Scientific-Technical Conference, Rosenergoatom, Moscow, 2006.

    Google Scholar 

  6. S. K. Chang et al., “Vane Effects of a Spacer Grid on Turbulent Mixing in a 5 × 5 Rod Bundle,” in Proceedings of the 10th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-10), Seoul, Korea, 2003.

  7. K. Rehme, “The Structure of Turbulent Flow through Rod Bundles,” Nucl. Eng. and Design 99, 141–154 (1987).

    Article  Google Scholar 

  8. S. V. Möller, “On Phenomena of Turbulent Flow through Rod Bundles,” Exp. Therm. Fluid Sci. 4, 25–35 (1991).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © O.N. Kashinskii, P.D. Lobanov, N.A. Pribaturin, A.S. Kurdyumov, S.E. Volkov, 2013, published in Teploenergetika.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kashinskii, O.N., Lobanov, P.D., Pribaturin, N.A. et al. Experimental study of the effect of spacer grid on the flow structure in fuel assemblies of the AES 2006 reactor. Therm. Eng. 60, 62–66 (2013). https://doi.org/10.1134/S0040601512070063

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0040601512070063

Keywords

Navigation