Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system

  • Published:
Thermal Engineering Aims and scope Submit manuscript

Abstract

Ways of improving the water chemistry used in the turbine generator stator’s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ts (Circular) 10/85 (e): Organization of Water Chemistry in a System for Cooling the Armature Windings of Turbine and Hydraulic Generators (SPO Soyuztekhenergo, Moscow, 1985) [in Russian].

  2. F. Mesnage and P. Moreaud, “Alternator Cooling Hollow Conductor Plugging,” in Proceedings of the REAVNIIAES-EDF Meeting, Moscow, March, 2007.

  3. R. Svoboda and H. G. Seipp, “Flow Restrictions in Water Cooled Generator Stator Coils — Prevention, Diagnosis, and Removal. Part 1: Behavior of Copper in Water-Cooled Generator Coils,” Power Plant Chem. 6(1), 7–14 (2004).

    Google Scholar 

  4. STO (Enterprise Standard) 1.1.1.02.013.0715-2009: Water Chemistry of the Main Process Circuit and Auxiliary Systems at Nuclear Power Plants Equipped with RBMK-1000 Reactors. Standards on the Quality of Working Medium and Means for Fulfilling Them (OAO Rosenergoatom Concern, Moscow, 2009) [in Russian].

  5. SP (Sanitary Code) 2.6.1.2612-10: Basic Sanitary Regulations for Ensuring Radiation Safety (OSPORB-99/2010) (Minzdrav Rossii, Moscow, 2010) [in Russian].

  6. RD (Guiding Document) EO 1.1.2.11.0805-2010: Water Chemistry in the System for Cooling the Turbine Generator Armature Windings at Nuclear Power Plants Equipped with VVER Reactors. Standards on the Quality of Working Medium and Means for Fulfilling Them (OAO Rosenergoatom Concern, Moscow, 2010) [in Russian].

Download references

Author information

Authors and Affiliations

Authors

Additional information

Original Russian Text © V.F. Tyapkov, I.Yu. Chudakova, O.A. Alekseenko, 2011, published in Teploenergetika.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tyapkov, V.F., Chudakova, I.Y. & Alekseenko, O.A. Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system. Therm. Eng. 58, 655–659 (2011). https://doi.org/10.1134/S004060151108012X

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S004060151108012X

Keywords

Navigation