Abstract
Problems encountered during retrofitting of oil coolers in operating steam turbine units are discussed. Results obtained from numerical simulation of oil leaks occurring in the gaps between the tube bundles of oil coolers are presented. Different design versions of a modernized MB-270–330 oil cooler are calculated, and the effect of different design parameters on the performance characteristics of such apparatuses is analyzed. The adopted technical solutions made it possible to develop the oil cooler that has been installed in 13 of the 15 800-MW turbine units that are currently in operation in Russia.
Similar content being viewed by others
References
N. F. Komarov, G. I. Moiseev, R. A. Petrosyan, et al., Boiler and Turbine Installations for 500- and 800-MW Power Units (Energiya, Moscow, 1979) [in Russian].
RTM (Guidelines) 108.020.126-80: A Procedure for Calculation and Design of Oil Coolers for Oil Supply Systems of Turbine Units (NPO TsKTI, Leningrad, 1982) [in Russian].
V. V. Olimpiev, “Effect of Design and Manufacturing Technology on the Operating Efficiency of Model MB Oil Coolers,” Teploenergetika, No. 5, 9–15 (2005) [Therm. Eng., No. 5 (2005)].
V. A. Permyakov, E. S. Levin, and G. V. Divova, Viscous-Liquid Heat Exchangers Used at Power Stations (Energoatomizdat, Leningrad, 1983) [in Russian].
Yu. M. Brodov, K. E. Aronson, A. Yu. Ryabchikov, et al., “Retrofitting of Oil Coolers for Steam Turbine Installations,” Teploenergetika, No. 12, 24–27 (1999) [Therm. Eng., No. 12 (1999)].
Yu. M. Brodov, V. A. Permyakov, and N. F. Kopylov, “The Advisability of Using Plate Heat Exchangers in the Circuits of Steam Turbine Units,” Elektr. Stn., No. 11, 30–33 (2000).
V. A. Permyakov, K. V. Permyakov, and A. N. Yakomenko, “Selecting the Type of Water-to-Water Heaters for Heat Supply Systems,” Prom. Teploenerg., No. 4, 37–44 (2000).
Yu. M. Brodov, K. E. Aronson, A. Yu. Ryabchikov, et al., “Development and Pilot-Industrial Check of a Set of Measures on Making the Operation of Oil Coolers More Efficient and Reliable,” Elektr. Stn., No. 12, 33–36 (1994).
K. E. Aronson, S. N. Blinkov, V. I. Brezgin, et al., Heat Exchangers for Power Engineering Installations. A Handbook for Higher Schools, Ed. by Yu. M. Brodov (SOKRAT, Yekaterinburg, 2003) [in Russian].
Yu. M. Brodov, K. E. Aronson, G. D. Bukhman, et al., Making the Heat Exchangers of Steam Turbine Units More Efficient and Reliable, Ed. by Yu. M. Brodov (GOU VPO UGTU-UPI, Yekaterinburg, 2004) [in Russian].
Yu. M. Brodov, K. E. Aronson, A. Yu. Ryabchikov, and G. A. Lokalov, “An Experimental Investigation of Heat Transfer for Viscous Liquid Flowing Over Bundles of Smooth and Profiled Tubes as Applied to Turbine Unit Oil Coolers,” Teploenergetika, No. 3, 13–17 (2008) [Therm. Eng., No. 3 (2008)].
V. G. Baron, Legends and Myths of Modern Thermal Engineering (Plate Heat Exchangers and Shell-and-Tube Apparatuses Constructed at TTAI), http://teploobmen.boom.ru/Publications/TTAI/art2/htm.
E. F. Kuznetsov, “Heat Transfer and Pressure Drop in Shell-and-Tube Oil Coolers,” Energomashinostr., No. 3, 42–45 (1970).
E. F. Kuznetsov, “Calculation of the Hydrodynamic and Thermal Characteristics of Shell-and-Tube Heat Exchangers,” Energomashinostr., No. 12, 20–23 (1978).
S. S. Berman, Design of Heat Exchangers for Turbine Units (Gosenergoizdat, Moscow-Leningrad, 1962) [in Russian].
A. Z. Rosinskii and G. G. Shklover, “The Influence of Design and Parametric Factors on Heat Transfer and Pressure Drop in Oil Coolers,” Teploenergetika, No. 4, 88–91 (1970).
V. A. Shvarts, E. A. Kobtseva, and I. Sh. Bushler, “Heat Transfer and Pressure Losses in Heat Exchangers with Disk-Ring Partitions,” Energomashinostr., No. 4, 23–24 (1968).
V. A. Andreev, Heat Exchangers for Viscous Liquids (Energiya, Leningrad, 1971) [in Russian].
N. D. Yakimov and V. V. Olimpiev, “Analyzing the Efficiency of an Oil Cooler with Enhanced Heat Transfer,” Izv. Vyssh. Uchebn. Zaved., Aviats. Tekhn., No. 1, 78–80 (2001).
K. E. Aronson, Yu. M. Brodov, M. A. Nirenshtein, et al., Thermohydraulic Calculation of Oil Coolers: A Software System, Certificate of Official Registration of a Computer Program No. 2003612363 dated October 20, 2003 (Russia).
E. F. Kuznetsov, “The Influence of Working Medium Overflows between Passes on the Thermal Characteristic of a Heat Exchanger,” Energomashinostr., No. 4, 14–15 (1979).
I. E. Idel’chik, A Handbook on Hydraulic Resistances (Mashinostroenie, Moscow, 1975) [in Russian].
B. Mohammadi and O. Pironeau, Analysis of the K-Epsilon Turbulence Model (John Wiley & Sons, Moscow, 1994).
I. D. Larionov, Yu. M. Brodov, and A. Yu. Ryabchikov, Geometrical Characteristics of Profiled Twisted Tubes, Available from NIIekonomiki, No. 288-EM (UPI, Yekaterinburg, 1986).
GOST (State Standard) 9916-77: Oil Coolers for Stationary Steam and Gas Turbines: Technical Specifications (Izd. Standartov, Moscow, 1985) [in Russian].
TU (Technical Specifications) 108.1454-87: Plain-Tube Oil Coolers for Stationary Steam and Gas Turbines. Technical Specifications (NPO TsKTI, Leningrad, 1987) [in Russian].
Author information
Authors and Affiliations
Additional information
Original Russian Text © K.E. Aronson, Yu.M. Brodov, A.Yu. Ryabchikov, D.V. Brezgin, V.I. Brezgin, 2009, published in Teploenergetika.
Rights and permissions
About this article
Cite this article
Aronson, K.E., Brodov, Y.M., Ryabchikov, A.Y. et al. Experience gained from development of modernized oil coolers for the oil supply system used in 800-MW turbines. Therm. Eng. 56, 636–643 (2009). https://doi.org/10.1134/S0040601509080035
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0040601509080035