Abstract
The results of investigation into the nature of damage to tube bends of the low-pressure evaporator of the P-90 heat recovery boiler installed at the Severozapadnaya cogeneration plant are presented. It has been found that damage was caused by cavitation wear due to action of steam-water flow.
Similar content being viewed by others
References
Hydraulic Design of Boiler Units. Standard Method (Energiya, Moscow, 1978) [in Russian].
P. A. Akol’zin, Prevention of Corrision of Steam Boilers Metals (Energiya, Moscow, 1975) [in Russian].
V. I. Nikitin, S. P. Adamova, G. Z. Khislavskii, and L. A. Gulyaeva, “Effect of Oxygen Dissolved in Water on Corrosion of Steels in Power Units,” Proc. of TsKTI, (231), 25–31 (1986)
V. I. Nikitin, A. M. Gvozd’, and T. Ya. Karpova, “Regularities of Transfer of Steel Corrosion Products into Aqueous Medium,” Teploenergetika, No. 8, 44–48(1981)
S. P. Kozyrev, Hyrdoabrasive Wear of Metals at Cavitation (Mashinostroenie, Moscow, 1971) [in Russian].
Erosion. Ed. by K. Pris. (Mir, Moscow, 1982) [in Russian].
V. V. Fomin, Hydraulic Erosion of Metals (Moscow, Mashinostroenie, 1977) [in Russian].
L. A. Glikman, Corrosion-Mechanical Strength of Metals (Moscow, Mashgiz, 1955) [in Russian].
Corrosion Ed. by L. L. Schraier (Moscow, Metallurgiya, 1981) [in Russian].
M. G. Timerbulatov, and G. I. Babushkina, “Cavitation Resistance of Various Steels,” Metal Science and Thermal Treatment of Metals, No. 8, 5–12 (1959)
Author information
Authors and Affiliations
Additional information
Original Russian Text © V.I. Nikitin, I.I. Belyakov, V.I. Breus, 2009, published in Teploenergetika.
Rights and permissions
About this article
Cite this article
Nikitin, V.I., Belyakov, I.I. & Breus, V.I. Damage to steam-generating tubes of low-pressure circuit of drum-type heat recovery boiler used in the PGU-450 combined-cycle unit at Severozapadnaya cogeneration plant. Therm. Eng. 56, 124–128 (2009). https://doi.org/10.1134/S0040601509020062