Abstract
The possibility is investigated of maintaining the steam reheat temperature by varying the gas/coal ratio in the fuel being burned. It is demonstrated that increasing the fraction of gas in the anthracite culm-natural gas mixture burned in the furnace of a TPP-210 boiler makes it possible to expand the load range in which the rated values of the steam reheat temperature are maintained.
Similar content being viewed by others
References
M.V. Meiklyar, Modern TKZ Boiler Units (Energiya, Moscow, 1978) [in Russian].
Thermal Design for Boiler Units. Standard Method (Energiya, Moscow, 1973) [in Russian].
A.A. Shatil’, Furnace Processes and Devices (Investigation and Design) (AOOT NPO TsKTI, St. Petersburg, 1997) [in Russian].
Author information
Authors and Affiliations
Additional information
Original Russian Text © A.N. Bezgreshnov, A.N. Ozerov, A.A. Belov, N.V. Usikov, V.I. Yakshov, 2006, published in Teploenergetika.
Rights and permissions
About this article
Cite this article
Bezgreshnov, A.N., Ozerov, A.N., Belov, A.A. et al. The possibilities of controlling steam reheat temperature by varying the gas/coal ratio. Therm. Eng. 53, 428–430 (2006). https://doi.org/10.1134/S004060150606005X
Issue Date:
DOI: https://doi.org/10.1134/S004060150606005X