Abstract
The contacts of a tin-lead solder (IIOC 61) with copper, brass and nickel in various types of disinfectants are investigated as galvanic couples where the solder always functions as the anode. The maximum relative increase in the corrosion rate is observed in a weakly alkaline hembar solution (guanidine-based biocidic polymer compound). The active oxidizers contained in delaxon and chlorantoin solutions can decompose due to their reduction at the cathodes of the couples.
References
Sevidova, E.K. and Roi, I.D., Fiziko-khimicheskaya mekhanika, L’vov, 2002, vol. 38, no. 6, p. 85.
Sovremennye sredstva dezinfektsii. Kharakteristika, naznachenie, perspektivy (The Modern Disinfectant Means. Characteristic, Purpose, and Prospects), Moscow: Meditsina, 1991.
Belous, V.Ya., Gurvich, L.Ya., Zhirnov, A.D. et al., Zashch. Met., 1998, vol. 34, no. 3, p. 266.
Roi, I.D., Sevidova, E.K., Blazheevskii, N.E., and Levitin, E.Ya., Zashch. Met., 1999, vol. 35, no. 6, p. 650.
Tomilov, A.P., Fioshin, M.Ya., and Smirnov, V.A., Elektrokhimicheskii sintez organicheskikh veshchestv (Electrochemical Synthesis of Organic Substances), Moscow: Khimiya, 1976.
Rachev, Kh. and Stefanova, S., Spravochnik po korrozii (Handbook on Corrosion), Translation from Bulgarian, Isaev, N.I., Ed., Moscow: Mir, 1982.
Author information
Authors and Affiliations
Additional information
Original Russian Text © E.K. Sevidova, I.D. Roi, I.I. Stepanova, 2006, published in Zashchita Metallov, 2006, Vol. 42, No. 3, pp. 326–328.
Rights and permissions
About this article
Cite this article
Sevidova, E.K., Roi, I.D. & Stepanova, I.I. The effect of disinfecting agents on the contact corrosion of medical instruments. Prot Met 42, 303–305 (2006). https://doi.org/10.1134/S0033173206030179
Received:
Issue Date:
DOI: https://doi.org/10.1134/S0033173206030179