Skip to main content
Log in

Direct arc atomic emission analysis of yttrium, gadolinium, and neodymium oxides

  • Analysis of Substances
  • Published:
Inorganic Materials Aims and scope

Abstract

The analytical potential of direct arc atomic emission detection of impurities in rare earth oxides (Y2O3, Cd2O3, and Nd2O3) on a Grand-Extra high-resolution spectrometer (VMK-Optoelektronika, Russia) is assessed. The conditions of analysis and spectrometer parameters are optimized. The detection threshold and lower limits for the content of a number of rare earth elements (Nd, Eu, Dy, Ho, Gd, Er, Tm, Yb, and Y) in these oxides are determined. The procedure for direct arc atomic emission analysis of yttrium, gadolinium, and neodymium oxides to detect rare earth impurities within the range of 0.001–0.1 wt % is elaborated; the procedure is characterized by improved metrological parameters compared to the standard method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Sarychev, G.A. and Tananaev, I.G., Position of rare earth metals in the periodic table, Tsvetn. Met., 2012, no. 3, pp. 24–31.

    Google Scholar 

  2. Sarychev, G.A., Kosynkin, V.D., and Glebov, V.A., Key elements of modernization, Tsvetn. Met., 2011, no. 4, pp. 38–44.

    Google Scholar 

  3. Gorbatenko, A.A. and Revina, E.I., A review of instrumental methods for determination of rare earth elements, Inorg. Mater., 2015, vol. 51, no. 14, pp. 1375–1388.

    Article  CAS  Google Scholar 

  4. Zawisza, B., Pytlakowska, K., Feist, B., et al., Determination of rare earth elements by spectroscopic techniques: a review, J. Anal. At. Spectrom., 2011, vol. 26, pp. 2373–2390.

    Article  CAS  Google Scholar 

  5. Djingova, R., Mihaylova, V., Lyubomirova, V., and Tsalev, D.L., Multielement analytical spectroscopy in plant ionomics research, Appl. Spectrosc. Rev., 2013, vol. 48, pp. 384–424.

    Article  CAS  Google Scholar 

  6. Beauchemin, D., Environmental analysis by inductively coupled plasma mass spectrometry, Mass Spectrom. Rev., 2010, vol. 29, pp. 560–592.

    CAS  Google Scholar 

  7. Wu, S., Hu, C., He, M., et al., Capillary microextraction combined with fluorinating assisted electrothermal vaporization inductively coupled plasma optical emission spectrometry for the determination of trace lanthanum, europium, dysprosium and yttrium in human hair, Talanta, 2013, vol. 115, pp. 342–348.

    Article  CAS  Google Scholar 

  8. GOST (State Standard) 23862.2–79: Rare Earth Metals and Their Oxides. Direct Spectral Method for Detecting Impurities of Rare Earth Oxides, 2003.

  9. Labusov, V.A., Put’makov, A.N., Zarubin, I.A., and Garanin, V.G., New multichannel optical spectrometers based on MAES analyzers, Zavod. Lab., Diagn. Mater., 2012, vol. 78, no. 1, part 2, pp. 7–13.

    Google Scholar 

  10. Karyakin, A.V., Anikina, L.I., and Laktionova, N.V., Spektral’nyi analiz redkozemel’nykh okislov (Spectral Analysis of Rare Earth Oxides), Moscow: Nauka, 1974, pp. 38–45.

    Google Scholar 

  11. GOST (State Standard) R ISO 5725-1-2002: Accuracy (Trueness and Precision) of Measurement Methods and Results. Part 1: Introduction and Basic Principles, 2002.

  12. GOST (State Standard) R ISO 5725-2-2002: Accuracy (Trueness and Precision) of Measurement Methods and Results. Part 2: Basic Method for the Determination of Repeatability and Reproducibility of Standard Measurement Method, 2002.

  13. GOST (State Standard) R ISO 5725-3-2002: Accuracy (Trueness and Precision) of Measurement Methods and Results. Part 3: Intermediate Measures of the Precision of a Standard Measurement Method, 2002.

  14. GOST (State Standard) R ISO 5725-4-2002: Accuracy (Trueness and Precision) of Measurement Methods and Results. Part 4: Basic Methods for the Determination of the Trueness of a Standard Measurement Method, 2002.

  15. GOST (State Standard) R ISO 5725-5-2002: Accuracy (Trueness and Precision) of Measurement Methods and Results. Part 5: Alternative Methods for the Determination of the Precision of a Standard Measurement Method, 2002.

  16. GOST (State Standard) R ISO 5725-6-2002: Accuracy (Trueness and Precision) of Measurement Methods and Results. Part 6: Use of Accuracy Values in Practice, 2002.

  17. GOST (State Standard) R 8.563-2009: State System for Ensuring the Uniformity of Measurements, 2010.

  18. RMG 61-2010: State System for Ensuring the Uniformity of Measurements. Indicators of Accuracy, Trueness, and Precision of the Methods of Quantitative Chemical Analysis. Evaluation Methods, 2012.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to E. S. Koshel’.

Additional information

Original Russian Text © E.S. Koshel’, V.B. Baranovskaya, T.Yu. Gubanova, 2015, published in Zavodskaya Laboratoriya, Diagnostika Materialov, 2015, Vol. 81, No. 12, pp. 8–13.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Koshel’, E.S., Baranovskaya, V.B. & Gubanova, T.Y. Direct arc atomic emission analysis of yttrium, gadolinium, and neodymium oxides. Inorg Mater 52, 1449–1454 (2016). https://doi.org/10.1134/S0020168516140090

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0020168516140090

Keywords

Navigation