Abstract
The resonance interaction of ionizing electrons with 7,7,8,8-tetracyanoquinodimethane (TCNQ) molecules was studied by negative-ion mass spectrometry. The installation of an energy filter in the ion source confirmed the possibility of a dissociation process on the surface of the ionization chamber of the ion source. The formation of negative fragment ions through a dissociation channel based on the Schottky effect was demonstrated.
Similar content being viewed by others
Notes
Computer-aided measurement and control (CAMAC) is a standard bus and modular-crate electronics standard for connecting measuring devices with digital equipment in data acquisition systems.
REFERENCES
Lukin, V.G. and Khvostenko, O.G., Usp. Fiz. Nauk, 2017, vol. 187, no. 9, p. 981.
Lukin, V.G., Khvostenko, O.G., and Tuimedov, G.M., Int. J. Mass Spectrom. Ion Processes, 2016, vols. 399–400, p. 17.
Lukin, V.G., Khvostenko, O.G., and Tuimedov, G.M., Tech. Phys. Lett., 2016, vol. 42, no. 2, p. 215.
Lukin, V.G., Khvostenko, O.G., and Tuimedov, G.M., Tech. Phys., 2017, vol. 62, no. 7, p. 998. doi org, p. 10.
Gaponov, V.I., Elektronika (chast’ I fizicheskie osnovy) (Electronics, Part I: Physical Principles), Moscow: Fizmatgiz, 1960.
Pshenichnyuk, S.A., Modelli, A., Lazneva, E.F., and Komolov, A.S., J. Phys. Chem. A, 2014, vol. 118, no. 34, p. 6810. doi org/https://doi.org/10.1021/jp505841c
Mazur, D.M., Zimens, M.E., Latkin, T.B., et al., Mass-Spektrometriya, 2019, vol. 16, no. 3, p. 214.
Lukin, V.G. and Tuimedov, G.M., Instrum. Exp. Tech., 2019, vol. 62, no. 1, p. 47.
Lukin, V.G. and Khvostenko, O.G., Usp. Fiz. Nauk, 2020, vol. 190, no. 5, p. 525.
Khvostenko, V.I., Mass-spektrometriya otritsatel’nykh ionov v organicheskoi khimii (Negative Ion Mass Spectrometry in Organic Chemistry), Moscow: Nauka, 1981.
Illenberger, E. and Smirnov, B.M., Usp. Fiz. Nauk, 1998, vol. 168, no. 7, p. 731.
Shultz, G.J., Rev. Mod. Phys., 1973, vol. 45, no. 3, p. 423.
Christophorou, L.G., Electron–Molecule Interactions and Their Applications, Orlando: Academic, 1984.
Tekhnicheskoe opisanie i instruktsiya po ekspluatatsii mass-spektrometra MI-1201V (MI-1201V Mass Spectrometer User Manual), Sumy: PO Elektron, 1981.
Trokhov, S.E., Prib. Tekh. Eksp., 1975, no. 3, p. 255.
Lukin, V.G. and Tuimedov, G.M., Instrum. Exp. Tech., 2013, vol. 56, no. 5, p. 565.
Khatymova, L.Z., Lukin, V.G., Tuimedov, G.M., and Khvostenko, O.G., High Energy Chem., 2019, vol. 53, no. 1, p. 58.
Mazunov, V.I., Khvostenko, V.I., and Fal’ko, V.S., Prib. Tekh. Eksp., 1985, no. 4, p. 170.
Polukarov, A.D., Goremykin, A.M., El’kin, Yu.N., Voinov, V.G., and Vasil’ev, B.K., Prib. Tekh. Eksp., 1998, no. 2, p. 142.
Lukin, V.G., Fal’ko, V.S., and Vyazovkin, D.E., Avtometriya, 1992, no. 1, p. 111.
Lukin, V.G., Vorob’ev, A.S., and Lomakin, G.S., Instrum. Exp. Tech., 2009, no. 4, p. 560.
Compton, R.N. and Cooper, C.D., J. Chem. Phys., 1977, vol. 66, no. 10, p. 4325. https://doi.org/10.1063/1.433743
Khvostenko, O.G., Kinzyabulatov, R.R., Khatymova, L.Z., and Tseplin, E.E., J. Phys. Chem. A, 2017, vol. 121, p. 7349. https://doi.org/10.1021/acs.jpca.7b05623
Khvostenko, O.G., Khatymova, L.Z., Lukin, V.G., et al., Chem. Phys. Lett., 2018, vol. 711, p. 81. https://doi.org/10.1016/j.cplett.2018.09.032
Khvostenko, O.G., Khatymova, L.Z., and Lukin, V.G., Bull. Russ. Acad. Sci.: Phys., 2020, vol. 84, no. 5, p. 555.
Klots, C.E., Compton, R.N., and Raaen, V.F., J. Chem. Phys., 1974, vol. 60, p. 1177.
Vedeneev, V.I., Gurvich, L.V., Kondrat’ev, V.N., et al., Energiya razryva svyazei. Spravochnik (Bond Dissociation Energies: A Handbook), Moscow: AN SSSR, 1962.
Knoll, M. and Eichmeier, J., Technische Elektronik, Band 2: Stromsteuernde und elektronenoptische Entladungsgeräte, Berlin: Springer, 1966.
Khvostenko, O.G., Khatymova, L.Z., Lukin, V.G., Tseplin, E.E., and Tuimedov, G.M., Butlerov Commun., 2013, vol. 35, no. 8, p. 9.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The authors declare that they have no conflicts of interest.
Additional information
Translated by V. Makhlyarchuk
Rights and permissions
About this article
Cite this article
Lukin, V.G., Khvostenko, O.G. & Tuimedov, G.M. Surface Phenomena in the Ionization Chamber of the Mass Spectrometer Ion Source. High Energy Chem 56, 114–121 (2022). https://doi.org/10.1134/S0018143922020072
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0018143922020072