Abstract
A mathematical model of a steam generator feed system at a power unit of a nuclear plant with variable values of transfer function coefficients is presented. The model is realized in the MATLAB/Simulink/Stateflow event-driven simulation.
Similar content being viewed by others
References
Ivanov, V.A., Regulirovanie energoblokov (Power Unit Control), Leningrad: Mashinostroenie, 1982.
Trofimov, A.I., Egupov, N.D., and Slekenichs, Ya.V., Printsipy postroeniya avtomaticheskikh regulyatorov teploenergeticheskikh protsessov AES (Principles of Development of Automatic Controllers for Heat and Power Processes at NPP), Moscow: Energoatomizdat, 1999.
D’yakonov, V.P., MATLAB 6.5 SP1/7 + Simulink 5/6 v matematike i modelirovanii (MATLAB 6.5 SP1/7 + Simulink 5/6 in Math and Simulation), Moscow: Solon-Press, 2005.
Demchenko, V.A. and Lozhechikov, V.F., Development of Mathematical Model of Segment of Steam Generator Feed at Power Unit with VVER), Tr. Odessk. Politekhn. Univ., Odessa, 1999, no. 2(8).
Isermann, R., Digital Control Systems, Berlin: Springer-Verlag, 1981. Translated under the title Tsifrovye sistemy upravleniya, Moscow: Mir, 1984.
Author information
Authors and Affiliations
Additional information
Original Russian Text © E.M. Raskin, L.A. Denisova, V.P. Sinitsyn, Yu.V. Nesterov, 2010, published in Avtomatizatsiya v Promyshlennosti, 2010, No. 7, pp. 3–7.
Rights and permissions
About this article
Cite this article
Raskin, E.M., Denisova, L.A., Sinitsyn, V.P. et al. Mathematical model of steam generator feed system at power unit of nuclear plant. Autom Remote Control 72, 1118–1126 (2011). https://doi.org/10.1134/S0005117911050213
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/S0005117911050213