Abstract
The separation parameters of a collector of heated ions are estimated in the context of the ion cyclotron resonance method of isotope separation. The separation power dU, the coefficient ΓC of the extraction of the target isotope, and the collector efficiency η are calculated. These parameters are investigated as functions of the repulsive potential U of the collector plates, the half-height a of the front screen, and the distance b between the plates. It is shown that the dependence of the collector efficiency η on the distance b between the plates has a pronounced maximum at b ≈ 2r * L , where r * L is the mean ion gyroradius.
Similar content being viewed by others
References
G. A. Askar’yan, V. A. Namiot, and A. A. Rukhadze, Pis’ma Zh. Tekh. Fiz. 1, 820 (1975) [Sov. Tech. Phys. Lett. 1, 356 (1975)].
J. M. Dawson, H. C. Kim, D. Arnush, et al., Phys. Rev. Lett. 37, 1547 (1976).
M. Mussetto, T. E. Romesser, D. Dixon, et al., in Abstracts of the IEEE International Conference on Plasma Science, San Diego, 1983, p. 70.
T. E. Ro messer, V. Vanek, J. Tang, et al. in Abstracts of the IEEE International Conference on Plasma Science, San Diego, 1983, p. 71.
A. C. La Fontaine and P. Louvet, Compte rendu des Journees sur les Isotopes Stables, Saclay, France, 1993, p. 332.
A. I. Karchevskiĭ, V. S. Laz’ko, Yu. A. Muromkin, et al., Fiz. Plazmy 19, 411 (1993) [Plasma Phys. Rep. 19, 214 (1993)].
I. L. Bass, R. E. Bonanno, R. P. Hackel, and R. Hammond, Appl. Opt. 31, 6993 (1992).
A. M. Rozen, Theory of Isotope Separation in Columns (Atomizdat, Moscow, 1960).
A. I. Karchevskiĭ and E. P. Potanin, Fiz. Plazmy 22, 1146 (1996) [Plasma Phys. Rep. 22, 1044 (1996)].
A. L. Ustinov, Preprint No. 5354/6, IAÉ (Institute of Atomic Energy, Moscow, 1991).
A. I. Karchevskiĭ and E. P. Potanin, Fiz. Plazmy 21, 416 (1995) [Plasma Phys. Rep. 21, 394 (1995)].
D. A. Dolgolenko, G. E. Zotin, A. I. Karchevskiĭ, et al. in Proceedings of the 4th All-Russia Conference “Physicochemical Processes Accompanying the Selection of Atoms and Molecules, ” Zvenigorod, 1999.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Karchevskiĭ, A.I., Potanin, E.P. Coefficient of the Extraction of the Target Isotope and Optimum Parameters of a Collector of Heated Ions in the Context of the ICR Method of Isotope Separation. Plasma Phys. Rep. 28, 565–571 (2002). https://doi.org/10.1134/1.1494054
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1134/1.1494054